E-ABR in Patients with Cochlear Implant: A Comparison between Patients with Malformed Cochlea and Normal Cochlea

被引:4
|
作者
Di Stadio, Arianna [1 ]
Dipietro, Laura [2 ]
De Lucia, Antonietta [3 ]
Trabalzini, Franco [4 ]
Ricci, Giampietro [1 ]
Martines, Francesco [5 ]
Pastore, Vincenzo [3 ]
della Volpe, Antonio [3 ]
机构
[1] Univ Perugia, Dept Otolaryngol, Perugia, Italy
[2] Highland Instrument, Cambridge, MA USA
[3] Santobono Hosp, Cochlear Implant Unit, Naples, Italy
[4] Meyer Univ Hosp, Dept Otolaryngol, Florence, Italy
[5] Univ Palermo, Dept Otolaryngol, Palermo, Italy
来源
关键词
Cochlear malformation; cochlear implant; EABR; ABR; cochlear nerve conduction; BRAIN-STEM RESPONSE; HEARING-LOSS; CHILDREN; EAR;
D O I
10.5152/iao.2019.6251
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
OBJECTIVES: This study aims to compare the electrical auditory brainstem response (EABR) following cochlear implant (CI) surgery in pediatric subjects with cochlear malformation and a normal cochlea, in order to assess the sensitivity of EABR and to evaluate the surgery outcome. MATERIALS and METHODS: A total of 26 pediatric subjects who were deaf and scheduled for CI surgery were enrolled into this case control study, Group A (n=20) included subjects with a normo-conformed cochlea. Group B (n=6) included subjects with cochlear malformation. Subjects were evaluated with EABR immediately (T0) and 6 months (T1) post-CI surgery.The EABR Waves III and V average amplitude and latency were compared across time, separately for each group, and across groups, separately for each time. RESULTS: Auditory brainstem response (ABR) could only be recorded in Group A. We were able to record EABR from all subjects atT0 and T1, and waves III and V were present in all the recorded signals. There were no statistically significant differences between T0 and T1 in EABR Waves III and V in terms of average amplitude and latency in neither group. When comparing Groups A and B, the only statistically significant difference was the average amplitude of wave V, both at T0 and T1. CONCLUSION: EABR is a valid tool to measure the auditory nerve integrity after CI surgery in patients with a normal and malformed cochlea, as shown by its ability to measure waves III and V when ABR is absent. The EABR testing should be performed before and after CI surgery, and EABR should be used as a measure of outcome, especially in patients with a malformed cochlea.
引用
收藏
页码:215 / 221
页数:7
相关论文
共 50 条
  • [41] Cochlear Implantation in Obliterated Cochlea: A Retrospective Analysis and Comparison between the IES Stiff Custom-Made Device and the Split-Array and Regular Electrodes
    Hoffmann, Julia Anna Christine
    Warnecke, Athanasia
    Timm, Max Eike
    Kludt, Eugen
    Prenzler, Nils Kristian
    Gaertner, Lutz
    Lenarz, Thomas
    Salcher, Rolf Benedikt
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (20)
  • [42] Recognition of monosyllabic words by cochlear implant patients and by normal-hearing subjects listening to words processed through cochlear implant signal processing strategies
    Dorman, MF
    Loizou, PC
    Fitzke, J
    Tu, ZM
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2000, 109 (12): : 64 - 66
  • [43] Comparison of speech recognition in cochlear implant patients with and without residual hearing: A review of indications
    Sargsyan, Gayane
    Kanaan, Natalie
    Lenarz, Thomas
    Lesinski-Schiedat, Anke
    COCHLEAR IMPLANTS INTERNATIONAL, 2021, 22 (05) : 257 - 264
  • [44] Comparison of Speech Perception Performance According to Prosody Change Between People With Normal Hearing and Cochlear Implant Users
    Kim, Eun Yeon
    Seol, Hye Yoon
    JOURNAL OF AUDIOLOGY AND OTOLOGY, 2024, 28 (02): : 119 - 125
  • [45] The Effects of Aging on Speech Perception in Noise: Comparison between Normal-Hearing and Cochlear-Implant Listeners
    Jin, Su-Hyun
    Liu, Chang
    Sladen, Douglas P.
    JOURNAL OF THE AMERICAN ACADEMY OF AUDIOLOGY, 2014, 25 (07) : 656 - 665
  • [46] Occurrence of primary brain tumors in cochlear implant patients in Sweden between 1989 and 2014
    Smeds, Henrik
    Wales, Jeremy
    Mathiesen, Tiit
    Talback, Mats
    Feychting, Maria
    CLINICAL EPIDEMIOLOGY, 2018, 10 : 1401 - 1405
  • [47] Speech perception as a function of cochlear coverage-comparison in bimodally hearing cochlear implant patients. German version
    Rader, Tobias
    Schrank, Leonhard
    Spiegel, Jennifer L. L.
    Nachtigaeller, Pascal
    Spiro, Judith E. E.
    Hempel, John-Martin
    Canis, Martin
    Mueller, Joachim
    HNO, 2023, 71 (08) : 504 - 512
  • [48] Correlation between NRT measurement level and behavioral levels in pediatrics cochlear implant patients
    Al Muhaimeed, Hamad
    Al Anazy, Fatma
    Hamed, Osama
    Shubair, Eba'a
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2010, 74 (04) : 356 - 360
  • [49] Prevalence and complications of MRI scans of cochlear implant patients: English version; [Häufigkeit und Komplikationen von MRT-Untersuchungen bei Cochlea-Implantat Patienten – English version: English version]
    Grupe G.
    Wagner J.
    Hofmann S.
    Stratmann A.
    Mittmann P.
    Ernst A.
    Todt I.
    HNO, 2017, 65 (Suppl 1) : 35 - 40
  • [50] Significance of endolymphatic sac surgery with and/or without simultaneous cochlea implant surgery in respect of vertigo control and speech perception in patients with Meniere's disease
    Spiegel, Jennifer L.
    Weiss, Bernhard G.
    Mueller, Joachim
    Hempel, John-Martin
    Rader, Tobias
    Bertlich, Mattis
    Canis, Martin
    Ihler, Friedrich
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2024, 281 (02) : 639 - 647