3D simulation of the image formation in soft x-ray microscopes

被引:6
|
作者
Selin, Marten [1 ]
Fogelqvist, Emelie [1 ]
Holmberg, Anders [1 ]
Guttmann, Peter [2 ]
Vogt, Ulrich [1 ]
Hertz, Hans M. [1 ]
机构
[1] KTH Royal Inst Technol, Albanova, Dept Appl Phys, S-10691 Stockholm, Sweden
[2] Helmholtz Zentrum Berlin Mat & Energie GmbH, Inst Soft Matter & Funct Mat, D-12489 Berlin, Germany
来源
OPTICS EXPRESS | 2014年 / 22卷 / 25期
基金
瑞典研究理事会;
关键词
RESOLUTION; CONTRAST;
D O I
10.1364/OE.22.030756
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In water-window soft x-ray microscopy the studied object is typically larger than the depth of focus and the sample illumination is often partially coherent. This blurs out-of-focus features and may introduce considerable fringing. Understanding the influence of these phenomena on the image formation is therefore important when interpreting experimental data. Here we present a wave-propagation model operating in 3D for simulating the image formation of thick objects in partially coherent soft x-ray microscopes. The model is compared with present simulation methods as well as with experiments. The results show that our model predicts the image formation of transmission soft x-ray microscopes more accurately than previous models. (C) 2014 Optical Society of America
引用
下载
收藏
页码:30756 / 30768
页数:13
相关论文
共 50 条
  • [41] 3D reconstruction of magnetization from dichroic soft X-ray transmission tomography
    Hierro-Rodriguez, Aurelio
    Gursoy, Doga
    Phatak, Charudatta
    Quiros, Carlos
    Sorrentino, Andrea
    Manuel Alvarez-Prado, Luis
    Velez, Maria
    Ignacio Martin, Jose
    Maria Alameda, Jose
    Pereiro, Eva
    Ferrer, Salvador
    JOURNAL OF SYNCHROTRON RADIATION, 2018, 25 : 1144 - 1152
  • [42] Laboratory Cryo Soft X-ray Tomography for 3D Imaging of Whole Cells
    Fahy, K.
    Sheridan, P.
    O'Reilly, F.
    McEnroe, T.
    Fyans, W.
    MOLECULAR BIOLOGY OF THE CELL, 2023, 34 (02) : 18 - 18
  • [43] X-RAY MICROSCOPY STUDIES WITH THE GOTTINGEN X-RAY MICROSCOPES
    THIEME, J
    SCHMAHL, G
    RUDOLPH, D
    NIEMANN, B
    GUTTMANN, P
    SCHNEIDER, G
    DIEHL, M
    WILHEIN, T
    INSTITUTE OF PHYSICS CONFERENCE SERIES, 1993, (130): : 555 - 568
  • [44] 3D/2D image registration: The impact of X-ray views and their number
    Tomazevic, Dejan
    Likar, Bostjan
    Pernus, Franjo
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2007, PT 1, PROCEEDINGS, 2007, 4791 : 450 - +
  • [45] Simulation of image formation using compound X-ray zone plates
    Nalimov, Anton G.
    Kotlyar, Victor V.
    OPTIK, 2016, 127 (18): : 7235 - 7241
  • [46] Simulation of coherent image formation in a hard X-ray CRL microscope
    Weitkamp, T
    Rau, C
    Snigirev, A
    Benner, B
    Kuhlmann, M
    Schroer, CG
    JOURNAL DE PHYSIQUE IV, 2003, 104 : 579 - 582
  • [47] Soft X-ray microscopy to image the sub-cellular structures of human stem cells in 3D at a nanometer resolution
    Vanslembrouck, Bieke
    Chen, Jian-Hua
    McDermott, Gerry
    Le Gros, Mark A.
    Larabell, Carolyn A.
    BIOPHYSICAL JOURNAL, 2022, 121 (03) : 498A - 498A
  • [48] RESOLUTION IN SOFT-X-RAY MICROSCOPES
    JACOBSEN, C
    KIRZ, J
    WILLIAMS, S
    ULTRAMICROSCOPY, 1992, 47 (1-3) : 55 - 79
  • [49] Animated Depth Employing Image Synthesis for 3D Security X-ray Imaging
    Abusaeeda, O.
    Evans, J. P. O.
    Downes, D.
    Chan, J. W.
    2011 IEEE INTERNATIONAL SYMPOSIUM ON SIGNAL PROCESSING AND INFORMATION TECHNOLOGY (ISSPIT), 2011, : 161 - 166
  • [50] Characterization of the morphology of cellular ceramics by 3D image processing of X-ray tomography
    Maire, Eric
    Colombo, Paolo
    Adrien, Jerome
    Babout, Laurent
    Biasetto, Lisa
    JOURNAL OF THE EUROPEAN CERAMIC SOCIETY, 2007, 27 (04) : 1973 - 1981