3D simulation of the image formation in soft x-ray microscopes

被引:6
|
作者
Selin, Marten [1 ]
Fogelqvist, Emelie [1 ]
Holmberg, Anders [1 ]
Guttmann, Peter [2 ]
Vogt, Ulrich [1 ]
Hertz, Hans M. [1 ]
机构
[1] KTH Royal Inst Technol, Albanova, Dept Appl Phys, S-10691 Stockholm, Sweden
[2] Helmholtz Zentrum Berlin Mat & Energie GmbH, Inst Soft Matter & Funct Mat, D-12489 Berlin, Germany
来源
OPTICS EXPRESS | 2014年 / 22卷 / 25期
基金
瑞典研究理事会;
关键词
RESOLUTION; CONTRAST;
D O I
10.1364/OE.22.030756
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In water-window soft x-ray microscopy the studied object is typically larger than the depth of focus and the sample illumination is often partially coherent. This blurs out-of-focus features and may introduce considerable fringing. Understanding the influence of these phenomena on the image formation is therefore important when interpreting experimental data. Here we present a wave-propagation model operating in 3D for simulating the image formation of thick objects in partially coherent soft x-ray microscopes. The model is compared with present simulation methods as well as with experiments. The results show that our model predicts the image formation of transmission soft x-ray microscopes more accurately than previous models. (C) 2014 Optical Society of America
引用
收藏
页码:30756 / 30768
页数:13
相关论文
共 50 条
  • [1] 3D X-RAY IMAGE COMPOSITION
    Armeanu, Constantin Catalin
    [J]. UNIVERSITY POLITEHNICA OF BUCHAREST SCIENTIFIC BULLETIN-SERIES A-APPLIED MATHEMATICS AND PHYSICS, 2016, 78 (01): : 309 - 320
  • [2] PARTIALLY COHERENT IMAGE-FORMATION WITH X-RAY MICROSCOPES
    JOCHUM, L
    MEYERILSE, W
    [J]. APPLIED OPTICS, 1995, 34 (22): : 4944 - 4950
  • [3] Simulation of partially coherent image formation in a compact soft X-ray microscope
    von Hofsten, Olov
    Takman, Per A. C.
    Vogt, Ulrich
    [J]. ULTRAMICROSCOPY, 2007, 107 (08) : 604 - 609
  • [4] Simulation of the X-ray image formation process
    Gouzinis, H
    Viant, WJ
    Ward, JW
    [J]. PROCEEDINGS OF THE INDUSTRIAL & BUSINESS SIMULATION SYMPOSIUM, 1999, : 98 - 103
  • [5] 3D X-ray image guidance in interventional radiology
    Niessen, W. J.
    van de Kraats, E. B.
    Baert, S. A. M.
    van Walsum, Th.
    [J]. 2007 4TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING : MACRO TO NANO, VOLS 1-3, 2007, : 1000 - 1003
  • [6] X3D: 3D X-ray lithography and development simulation for MEMS
    Hafizovic, S
    Hirai, Y
    Tabata, O
    Korvink, JG
    [J]. BOSTON TRANSDUCERS'03: DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 2003, : 1570 - 1573
  • [7] Image analysis of X-ray microtomograms of soft materials during convective drying:: 3D measurements
    Léonard, A
    Blacher, S
    Marchot, P
    Pirard, JP
    Crine, M
    [J]. JOURNAL OF MICROSCOPY-OXFORD, 2005, 218 : 247 - 252
  • [8] Automated 3D cytoplasm segmentation in soft X-ray tomography
    Erozan, Ayse
    Loesel, Philipp D.
    Heuveline, Vincent
    Weinhardt, Venera
    [J]. ISCIENCE, 2024, 27 (06)
  • [9] 3D ray-tracing simulation of X-ray laser amplification
    Temporal, M
    Jacquemot, S
    Bonnet, L
    Decoster, A
    [J]. JOURNAL DE PHYSIQUE IV, 2001, 11 (PR2): : 305 - 308
  • [10] X-RAY MICROSCOPES
    HOWELLS, MR
    KIRZ, J
    SAYRE, D
    [J]. SCIENTIFIC AMERICAN, 1991, 264 (02) : 88 - 94