Towards the establishment of national diagnostic reference levels in Tunisia: a multicentre survey in paediatric CT

被引:3
|
作者
Bouaoun, Abir [1 ]
Ben Omrane, Latifa [1 ,2 ]
Khomssi, Wiem Douira [3 ]
机构
[1] Univ Tunis El Manar, Higher Inst Med Technol Tunis ISTMT, Lab Biophys & Med Technol LR13ES07, Tunis, Tunisia
[2] Natl Ctr Radiat Protect CNRP, Tunis, Tunisia
[3] Childrens Hosp, Tunis, Tunisia
关键词
patient dose; paediatric CT; DRL; optimisation; COMPUTED-TOMOGRAPHY; RADIATION-EXPOSURE; STRATEGIES; COUNTRIES;
D O I
10.1088/1361-6498/ac767a
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This work focuses on the determination of the radiation doses for a total sample of 916 children, categorised into four age groups (<1, 1-5, <5-10, <10-15 years) undergoing the most frequent paediatric CT scans performed in different scan facilities in Tunisia in order to establish the national diagnostic reference levels (DRLs). Dose evaluation concerned the dosimetric indicators: volume computed tomography dose index (CTDIvol) and dose-length product (DLP). The different paediatric CT protocols and practices were also evaluated. The results show a large variation in doses between different radiology departments. For head scans, the respective DRLs for children aged <1, 1-5, 5-10 and 10-15 years were 26, 38, 51 and 51 mGy, respectively, for CTDIvol and 384, 664, 873 and 978 mGy cm, respectively, for DLP. For the chest, the equivalent respective DRLs were 8, 10, 12 and 15 mGy for CTDIvol and 118, 330, 442 and 526 mGy cm for DLP. For the abdomen, the respective DRLs were 9, 13, 19 and 18 mGy for CTDIvol and 353, 485, 592 and 1073 mGy cm for DLP. This study shows that the optimisation of paediatric CT procedures should be a priority, especially within regional hospitals. The implementation of corrective actions will take place after the initial DRLs. These actions, including recommendations and guidelines to good practice, should be a joint effort of all stakeholders, including health authorities, the radiation protection regulator, professional societies and universities.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] AN AUSTRALIAN LOCAL DIAGNOSTIC REFERENCE LEVELS FOR PAEDIATRIC FDG PET/CT
    Alkhybari, E.
    Kitsos, T.
    Willowson, K.
    McEntee, M.
    Brennan, P.
    Howman-Giles, R.
    Kench, P.
    [J]. INTERNAL MEDICINE JOURNAL, 2018, 48 : 12 - 12
  • [22] PATIENT DOSES IN PAEDIATRIC CT: FEASIBILITY OF SETTING DIAGNOSTIC REFERENCE LEVELS
    Jarvinen, H.
    Merimaa, K.
    Seuri, R.
    Tyrvainen, E.
    Perhomaa, M.
    Savikurki-Heikkila, P.
    Svedstrom, E.
    Ziliukas, J.
    Lintrop, M.
    [J]. RADIATION PROTECTION DOSIMETRY, 2011, 147 (1-2) : 142 - 146
  • [23] Establishment of CT diagnostic reference levels (DRLs) for a Singapore healthcare cluster
    Arlany, L.
    Toh, H. G.
    Nazir, B.
    Ng, J. J.
    Tay, Y. H.
    Tay, Y. S.
    Poon, C. J. X.
    Lee, L. N.
    Fum, W. K. S.
    Lee, E. Y. T.
    Mariah, S., I
    Fortier, M., V
    Tham, W. P.
    Chew, L. L.
    Chong, K. H. E.
    Chong, L. R.
    [J]. RADIOGRAPHY, 2023, 29 (01) : 184 - 189
  • [24] Establishment of CT diagnostic reference levels in select procedures in South India
    Saravanakumar, A.
    Vaideki, K.
    Govindarajan, K. N.
    Devanand, B.
    Jayakumar, S.
    Sharma, S. D.
    [J]. INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2016, 14 (04): : 341 - 347
  • [25] Establishment of local diagnostic reference levels for CT colonography at a tertiary hospital
    Kozlowski, Filip M.
    van Reenen, Christoffel J.
    Trauernicht, Christoph J.
    [J]. SA JOURNAL OF RADIOLOGY, 2024, 28 (01): : 1 - 5
  • [26] Establishment of National Diagnostic Reference Levels for Administered Activity in Diagnostic Nuclear Medicine in Thailand
    Suttho, Dutsadee
    [J]. JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2024, 52 (02) : 158 - 162
  • [27] Towards Diagnostic Reference Levels in PET-CT in Finland
    Liukkonen, J.
    Kaijaluoto, S. P.
    Toroi, P. M.
    Bly, R.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S469 - S469
  • [28] Canadian Computed Tomography Survey: National Diagnostic Reference Levels
    Wardlaw, Graeme M.
    Martel, Narine
    [J]. MEDICAL PHYSICS, 2016, 43 (08) : 4932 - 4933
  • [29] Establishment of national diagnostic reference levels for computed tomography procedures in Sri Lanka: first nationwide dose survey
    Amalaraj, T.
    Satharasinghe, Duminda
    Pallewatte, Aruna
    Jeyasugiththan, Jeyasingam
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2022, 42 (02)