Mass transfer coefficients in a Kuhni extraction column

被引:53
|
作者
Hemmati, Alireza [1 ]
Torab-Mostaedi, Meisam [2 ]
Asadollahzadeh, Mehdi [2 ]
机构
[1] Islamic Azad Univ, Dept Chem Engn, Fac Engn, South Tehran Branch, Tehran, Iran
[2] Nucl Sci & Technol Res Inst, Nucl Fuel Cycle Res Sch, Tehran, Iran
来源
关键词
Kuhni extraction column; Mass transfer coefficient; Axial diffusion model; Effective diffusivity; Enhancement factor; LIQUID-LIQUID-EXTRACTION; EFFECTIVE DIFFUSIVITY; PREDICTION; DROPS;
D O I
10.1016/j.cherd.2014.07.011
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Mass transfer performance has been presented for a 117 diameter Kuhni extraction column using axial diffusion model for two different liquid-liquid systems. The influence of operating variables including the rotor speed as well as the continuous and dispersed phase flowrates on the volumetric overall mass transfer coefficients is investigated. Effective diffusivity is substituted for molecular diffusivity in the Grober equation for prediction of dispersed phase overall mass transfer coefficients. The enhancement factor is determined experimentally and there from an empirical correlation is derived for prediction of enhancement factor in terms of Reynolds number and dispersed phase holdup. The prediction of overall mass transfer coefficients from the presented equation is in good agreement with experimental data. (C) 2014 The Institution of Chemical Engineers. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:747 / 754
页数:8
相关论文
共 50 条
  • [41] Enzyme mass transfer coefficient in a sieve plate extraction column
    Bhawsar, P.C.M.
    Pandit, A.B.
    Sawant, S.B.
    Joshi, J.B.
    1600, Elsevier Sequoia SA, Lausanne, Switzerland (55): : 1 - 2
  • [42] Investigation of the mass transfer parameters of caffeine extraction in a packed column
    Bilgin, Mehmet
    Hasdemir, I. Metin
    Aydin, Ahmet
    Dramur, Umur
    Turkish Journal of Engineering & Environmental Sciences/Turk Muhendislik ve Cevre Bilimleri Dergisi, 22 (06): : 471 - 477
  • [43] CALCULATING COEFFICIENTS OF MASS-TRANSFER IN LIQUID EXTRACTION PROCESS
    OSTROVSK.MV
    ABRAMZON, AA
    KALUGINA, SK
    ZHURNAL PRIKLADNOI KHIMII, 1972, (MAR) : 574 - &
  • [44] Enhancement of single liquid drop mass transfer coefficients in a perforated plate column
    Hashem, MA
    El-Bassuoni, AA
    COMPUTATIONAL METHODS IN MULTIPHASE FLOW, 2001, 29 : 109 - 118
  • [45] Mass transfer characteristics in extraction column with trapezoidal pulsed sieve plate
    Zhang, Weibo
    Dai, Weizhi
    Hu, Xi'en
    Gao Xiao Hua Xue Gong Cheng Xue Bao/Journal of Chemical Engineering of Chinese Universities, 1993, 7 (03): : 214 - 220
  • [46] The effects of a surfactant on the mass transfer in spray-tower extraction column
    Chen, LH
    Lee, YL
    CHEMICAL ENGINEERING JOURNAL, 1999, 73 (01) : 77 - 81
  • [47] MASS-TRANSFER EFFICIENCIES OF COLUMN CONTACTORS IN SUPERCRITICAL EXTRACTION SERVICE
    LAHIERE, RJ
    FAIR, JR
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1987, 26 (10) : 2086 - 2092
  • [48] MASS TRANSFER STUDIESIN A PULSED EXTRACTION COLUMN - LONGITUDINAL CONCENTRATION PROFILES
    SMOOT, LD
    BABB, AL
    INDUSTRIAL & ENGINEERING CHEMISTRY FUNDAMENTALS, 1962, 1 (02): : 93 - &
  • [49] The effects of a surfactant on the mass transfer in spray-tower extraction column
    Department of Applied Chemistry, Chia-Nan Coll. Pharm. and Sci., 717, Tainan, Taiwan
    Chem. Eng. J., 1 (77-81):
  • [50] Mass transfer coefficient in the eductor liquid-liquid extraction column
    Bahare Esmaeeli
    Ahad Ghaemi
    Mansour Shirvani
    Mostafa Hosseinzadeh
    ChineseJournalofChemicalEngineering, 2021, 40 (12) : 27 - 35