A clinical analysis of 4-and 6-year follow-up results after cervical disc replacement surgery using the Bryan Cervical Disc Prosthesis Clinical article

被引:76
|
作者
Goffin, Jan [1 ]
van Loon, Johan [1 ]
Van Calenbergh, Frank [1 ]
Lipscomb, Bailey [2 ]
机构
[1] Katholieke Univ Leuven, Dept Neurosurg, Louvain, Belgium
[2] Medtron Spinal & Biol, Memphis, TN USA
关键词
cervical disc degeneration; cervical disc arthroplasty; Bryan Cervical Disc Prosthesis; cervical spine; ARTIFICIAL DISC; SINGLE-LEVEL; DISEASE; RELIABILITY; FUSION;
D O I
10.3171/2009.9.SPINE09129
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. In this study, long-term results are presented from clinical studies of the Bryan Cervical Disc Prosthesis at University Hospital Gasthuisberg in Leuven, Belgium. A total of 98 patients (89 with 1-level and 9 with 2-level implantations) agreed to participate in follow-up studies for up to 10 years postoperatively. This article focuses on the 4- and 6-year results. Patients in one of the clinical studies had either radiculopathy or myelopathy associated with spondylosis and/or disc herniations that did not respond to conservative treatment. Patients from the other clinical study received commercially available Bryan devices and the stud), protocol did not have specific inclusion/exclusion criteria. More than 90% of the patients were considered to have radiculopathy. Methods. Clinical measurements discussed in the article include the 36-Item Short Form Health Survey. Neck Disability Index, numerical ratings of neck and arm pain. neurological outcomes, and Odom classification. Angular motion findings from lateral flex ion-extension radiographs are also presented. The occurence of adverse events and second surgeries are examined as all indicator of device safety. Results. The clinical outcomes at 4 and 6 years postoperatively appear consistent With the Previously reported results at 1 and 2 years postoperatively. The mean angular motion results at 4 and 6 years postoperatively for 1-level patients were 7.3 and 7.7 degrees. respectively. Two-level patients had slightly less motion at 4 and 6 years postoperatively with mean caudad values of 5.7 and 6.0 degrees, respectively, and cephalad values of 4.2 and 6.2 degrees. respectively. Efforts were made to capture adverse events, regardless of their nature and relatedness to the study surgery. This effort resulted in a relatively high number of recorded events. However, only 6 patients experienced events that were judged by the investigator to be related, either possibly or definitely, to the Bryan device. These events included device migration. device removal, and hoarseness and vocal cord paralysis, as well as 3 cases involving pain and neurological symptoms. Eight patients underwent further neck surgery to treat symptoms. Conclusions. The favorable clinical and angular motion outcomes that were Previously noted at 1- and 2-years' follow-up after cervical disc replacement with the Bryan Cervical Disc Prosthesis appear to persist after 4 and 6 years of follow-up. (DOI: 10.3171/2009.9.SPINE09129)
引用
收藏
页码:261 / 269
页数:9
相关论文
共 50 条
  • [21] Subsequent surgery rates after cervical total disc replacement using a Mobi-C Cervical Disc Prosthesis versus anterior cervical discectomy and fusion: a prospective randomized clinical trial with 5-year follow-up
    Jackson, Robert J.
    Davis, Reginald J.
    Hoffman, Gregory A.
    Bae, Hyun W.
    Hisey, Michael S.
    Kim, Kee D.
    Gaede, Steven E.
    Nunley, Pierce Dalton
    [J]. JOURNAL OF NEUROSURGERY-SPINE, 2016, 24 (05) : 734 - 745
  • [22] Intervertebral disc replacement for cervical degenerative disease -: clinical results and functional outcome at two years in patients implanted with the Bryan® cervical disc prosthesis
    Heidecke, V.
    Burkert, W.
    Brucke, M.
    Rainov, N. G.
    [J]. ACTA NEUROCHIRURGICA, 2008, 150 (05) : 453 - 459
  • [23] Intervertebral disc replacement for cervical degenerative disease – clinical results and functional outcome at two years in patients implanted with the Bryan® cervical disc prosthesis
    V. Heidecke
    W. Burkert
    M. Brucke
    N. G. Rainov
    [J]. Acta Neurochirurgica, 2008, 150
  • [24] Clinical and Radiological Analysis of Bryan Cervical Artificial Disc Replacement for "Skip" Multi-Segment Cervical Spondylosis: Long-Term Follow-Up Results
    Shang, Zikun
    Zhang, Yingze
    Zhang, Di
    Ding, Wenyuan
    Shen, Yong
    [J]. MEDICAL SCIENCE MONITOR, 2017, 23 : 5254 - 5263
  • [25] Ten-year Outcomes of Cervical Disc Replacement With the BRYAN Cervical Disc Results From a Prospective, Randomized, Controlled Clinical Trial
    Lavelle, William F.
    Riew, K. Daniel
    Levi, Allan D.
    Florman, Jeffrey E.
    [J]. SPINE, 2019, 44 (09) : 601 - 608
  • [26] Reduced pain after surgery for cervical disc protrusion/stenosis:: a 2 year clinical follow-up
    Löfgren, H
    Johansen, F
    Skogar, Ö
    Levander, B
    [J]. DISABILITY AND REHABILITATION, 2003, 25 (18) : 1033 - 1043
  • [27] Clinical and radiographic results of Bryan cervical total disc replacement: 4-year outcomes in a prospective study
    Zhang, Zhenxiang
    Gu, Beibei
    Zhu, Wei
    Wang, Quanming
    Zhang, Wenjie
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2013, 133 (08) : 1061 - 1066
  • [28] Clinical and radiographic results of Bryan cervical total disc replacement: 4-year outcomes in a prospective study
    Zhenxiang Zhang
    Beibei Gu
    Wei Zhu
    Quanming Wang
    Wenjie Zhang
    [J]. Archives of Orthopaedic and Trauma Surgery, 2013, 133 : 1061 - 1066
  • [29] Cervical disc arthroplasty with the Baguera C prosthesis: clinical and radiological results of a 10-year follow-up study
    P. Fransen
    D. Noriega
    A. Chatzisotiriou
    V. Pointillart
    [J]. European Spine Journal, 2023, 32 : 3533 - 3539
  • [30] Cervical disc arthroplasty with the Baguera C prosthesis: clinical and radiological results of a 10-year follow-up study
    Fransen, P.
    Noriega, D.
    Chatzisotiriou, A.
    Pointillart, V.
    [J]. EUROPEAN SPINE JOURNAL, 2023, 32 (10) : 3533 - 3539