Improved time response for large area microchannel plate photomultiplier tubes in fusion diagnostics

被引:6
|
作者
Milnes, J. S. [1 ]
Horsfield, C. J. [2 ]
Conneely, T. M. [1 ]
Howorth, J. [1 ]
机构
[1] Photek Ltd, St Leonards On Sea TN38 9NS, E Sussex, England
[2] AWE, Reading RG7 4PR, Berks, England
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2014年 / 85卷 / 11期
关键词
D O I
10.1063/1.4886759
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Fusion diagnostics that utilise high speed scintillators often need to capture a large area of light with a high degree of time accuracy. Microchannel plate (MCP) photomultiplier tubes (PMTs) are recognised as the leading device for capturing fast optical signals. However, when manufactured in their traditional proximity focused construction, the time response performance is reduced as the active area increases. This is due to two main factors: the capacitance of a large anode and the difficulty of obtaining small pore MCPs with a large area. Collaboration between Photek and AWE has produced prototype devices that combine the excellent time response of small area MCP-PMTs with a large active area by replacing the traditional proximity-gap front section with an electro-optically focused photocathode to MCP. We present results from both single and double MCP devices with a 40 mm diameter active area and show simulations for the 100 mm device being built this year. (C) 2014 AIP Publishing LLC.
引用
收藏
页数:3
相关论文
共 50 条
  • [31] TIME RESOLUTION STUDY OF A CPPM 320 UV MICROCHANNEL-PLATE PHOTOMULTIPLIER WITH A BaF2 SCINTILLATION CRYSTAL.
    De Vries, J.
    Van Eijk, C.W.E.
    Nuclear instruments and methods in physics research, 1985, A239 (02): : 243 - 250
  • [32] TIME RESPONSE OF SMALL SIDE-ON PHOTOMULTIPLIER TUBES IN TIME-CORRELATED SINGLE-PHOTON COUNTING MEASUREMENTS
    MEISTER, EC
    WILD, UP
    KLEINBOLTING, P
    HOLZWARTH, AR
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1988, 59 (03): : 499 - 501
  • [33] Large area microchannel plate detector with amorphous silicon pixel array readout for fast neutron radiography
    Ambrosi, RM
    Fraser, GW
    Feller, B
    Street, R
    Watterson, JIW
    White, P
    Downing, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 500 (1-3): : 351 - 361
  • [34] Detection of Large Ions in Time-of-Flight Mass Spectrometry: Effects of Ion Mass and Acceleration Voltage on Microchannel Plate Detector Response
    Liu, Ranran
    Li, Qiyao
    Smith, Lloyd M.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2014, 25 (08) : 1374 - 1383
  • [35] ANALYSIS OF MICROCHANNEL PLATE RESPONSE IN RELATION TO PULSED LASER TIME-OF-FLIGHT PHOTOEMISSION SPECTROSCOPY
    ANACKER, DC
    ERSKINE, JL
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1991, 62 (05): : 1246 - 1255
  • [36] PERFORMANCE COMPARISON OF A SINGLE-PHOTON AVALANCHE-DIODE WITH A MICROCHANNEL-PLATE PHOTOMULTIPLIER IN TIME-CORRELATED SINGLE-PHOTON COUNTING
    LOUIS, T
    SCHATZ, GH
    KLEINBOLTING, P
    HOLZWARTH, AR
    RIPAMONTI, G
    COVA, S
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1988, 59 (07): : 1148 - 1152
  • [37] Improvement of time resolution in large area single gap Resistive Plate Chambers
    Bhatt, A. D.
    Majumder, G.
    Mondal, N. K.
    Pathaleswar
    Satyanarayana, B.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 844 : 53 - 61
  • [38] THE ELASTIC RESPONSE OF A LARGE PLATE TO A GAUSSIAN DISTRIBUTION OF PRESSURE VARYING WITH TIME
    SNEDDON, IN
    PROCEEDINGS OF THE CAMBRIDGE PHILOSOPHICAL SOCIETY, 1946, 42 (03): : 338 - 341
  • [39] A position-sensitive large-area microchannel plate detector with digital data-acquisition system for studies of exotic nuclei
    Korkulu, Z.
    Stuhl, L.
    Naimi, S.
    Dombradi, Zs.
    Hahn, K. I.
    Moon, J. Y.
    Ahn, D. S.
    Halasz, Z.
    Hudson-Chang, G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2023, 541 : 232 - 235
  • [40] Effect of serum volume and time of exposure to gel barrier tubes on results for progesterone by Roche Diagnostics Elecsys 2010 - Response
    Henne, V
    CLINICAL CHEMISTRY, 1999, 45 (09) : 1575 - 1575