Indium oxide nanoparticles modified carbon paste electrode for sensitive voltammetric determination of aromatase inhibitor formestane

被引:23
|
作者
Ibrahim, Mohamed [1 ]
Temerk, Yassien [1 ]
Ibrahim, Hossieny [1 ]
Kotb, Mohamed [1 ]
机构
[1] Assiut Univ, Fac Sci, Dept Chem, Assiut 71516, Egypt
关键词
Indium oxide nanoparticles; Modified carbon paste electrode; Formestane; Determination; Voltammetry; GAS CHROMATOGRAPHY/MASS SPECTROMETRY; DIFFERENTIAL-PULSE VOLTAMMETRY; BREAST-CANCER PATIENTS; MASS-SPECTROMETRY; INTRAMUSCULAR; 4-HYDROXYANDROSTENEDIONE; URINE; IDENTIFICATION; NANOTUBE; VALIDATION; LETROZOLE;
D O I
10.1016/j.snb.2014.12.034
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper reports a novel, simple and sensitive electrochemical method for the determination of formestane (FMT) in aqueous media (BR buffer solution, pH 5.2) on indium oxide nanoparticles modified carbon paste electrode (In2O3 NPs/CPE). The prepared In2O3 nanoparticles were characterized by X-ray diffraction (XRD) and scanning electron microscopy (SEM). The fabricated In2O3 NPs/CPE displayed high effective surface area, more reactive sites and excellent electrochemical catalytic activity toward the oxidation of FMT. The voltammetric oxidation of FMT was studied at a carbon paste and indium oxide nanoparticles modified carbon paste electrodes by cyclic voltammetry and its determination was carried out by square wave anodic adsorptive stripping voltammetry (SWAASV). The electrochemical parameters such as surface concentration (Gamma), electron transfer coefficient (alpha), and the electron transfer rate constant (k(s)) of FMT at the modified electrode were calculated. Under the optimal conditions at In2O3 NPs/CPE, a linear relationship was realized between the anodic peak currents and FMT concentrations in the range of 0.19-2.91 mu M, with the detection limit of 6.2 x 10(-8) M. This modified electrode was used as a sensor for determination of FMT in blood serum and urine samples with satisfactory results. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:630 / 638
页数:9
相关论文
共 50 条
  • [21] Voltammetric determination of hydrochlorothiazide at a modified carbon paste electrode with polypyrrole nanotubes
    Mohammadnavaz, Arefeh
    Garkani-Nejad, Fariba
    ADMET AND DMPK, 2023, 11 (02): : 293 - 302
  • [22] Voltammetric determination of mifepristone at a DNA-modified carbon paste electrode
    K. Gu
    J. Zhu
    Y. Zhu
    J. Xu
    H.-Y. Chen
    Fresenius' Journal of Analytical Chemistry, 2000, 368 : 832 - 835
  • [23] VOLTAMMETRIC DETERMINATION OF GOLD USING A CARBON PASTE ELECTRODE MODIFIED WITH THIOBENZANILIDE
    CAI, XH
    KALCHER, K
    NEUHOLD, C
    DIEWALD, W
    MAGEE, RJ
    ANALYST, 1993, 118 (01) : 53 - 57
  • [24] MODIFIED CARBON-PASTE ELECTRODE FOR VOLTAMMETRIC DETERMINATION OF TRACE SILICON
    GURENTSOVA, OI
    PROKHOROVA, GV
    OSIPOVA, EA
    JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 47 (09) : 1224 - 1228
  • [25] Voltammetric determination terbinafine at carbon paste electrode modified with graphene nanosheets
    Hendawy, Hassan A. M.
    Radowan, Abdellatef A.
    Khaled, Elmorsy
    EGYPTIAN JOURNAL OF CHEMISTRY, 2023, 66 (03): : 103 - 112
  • [26] VOLTAMMETRIC DETERMINATION OF LINURON AT A CARBON-PASTE ELECTRODE MODIFIED WITH SEPIOLITE
    HERNANDEZ, P
    VICENTE, J
    GONZALEZ, M
    HERNANDEZ, L
    TALANTA, 1990, 37 (08) : 789 - 794
  • [27] VOLTAMMETRIC DETERMINATION OF CADMIUM ON A CARBON PASTE ELECTRODE MODIFIED WITH A CHELATING RESIN
    AGRAZ, R
    SEVILLA, MT
    PINILLA, JM
    HERNANDEZ, L
    ELECTROANALYSIS, 1991, 3 (4-5) : 393 - 397
  • [28] Voltammetric determination of mifepristone at a DNA-modified carbon paste electrode
    Gu, K
    Zhu, JJ
    Zhu, YL
    Xu, JZ
    Chen, HY
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 368 (08): : 832 - 835
  • [29] Simultaneous Voltammetric Determination of Mefenamic Acid and Paracetamol using Graphene Nanosheets/Nickel Oxide Nanoparticles Modified Carbon Paste Electrode
    Naeemy, Ali
    Gholam-Shahbazi, Rozhina
    Mohammadi, Ali
    JOURNAL OF ELECTROCHEMICAL SCIENCE AND TECHNOLOGY, 2017, 8 (04) : 282 - 293
  • [30] Fast and sensitive determination of captopril by voltammetric method using ferrocenedicarboxylic acid modified carbon paste electrode
    Karimi-Maleh, H.
    Ensafi, A. A.
    Allafchian, A. R.
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2010, 14 (01) : 9 - 15