Impact of the use of hydroxyethyl starch in granulocyte apheresis using Spectra Optia

被引:2
|
作者
Yoshihara, Satoshi [1 ,2 ]
Ikemoto, Junko [1 ]
Onomoto, Hitomi [1 ]
Sugiyama, Hiroki [1 ]
Okuda, Noriko [1 ]
Fukunaga, Keiko [2 ]
Yoshihara, Kyoko [1 ,2 ]
Kaida, Katsuji [2 ]
Ikegame, Kazuhiro [2 ]
Tamaki, Hiroya [2 ]
Okada, Masaya [2 ]
Osugi, Yuko [2 ]
Yamahara, Kenichi [1 ]
Higasa, Satoshi [1 ,2 ]
Fujimori, Yoshihiro [1 ,2 ]
机构
[1] Hyogo Coll Med Hosp, Dept Transfus Med & Cellular Therapy, Nishinomiya, Hyogo, Japan
[2] Hyogo Coll Med Hosp, Dept Hematol, Nishinomiya, Hyogo, Japan
关键词
apheresis; collection efficiency; granulocyte transfusion; hydroxyethyl starch; NEUTROPENIC PATIENTS; TRANSFUSIONS; COLLECTION; DONORS; INFECTION; MORTALITY; EFFICACY; INDEX; AREA; RISK;
D O I
10.1111/tme.12795
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives To determine the impact of the use of hydroxyethyl starch (HES) in granulocyte apheresis using Spectra Optia. Background Granulocyte transfusion (GT) is a therapeutic option for neutropenic patients with severe bacterial or fungal infections. Recent studies in emergency medicine have shown the potential risk of using HES, which is routinely used in granulocyte apheresis to increase yield by sedimenting red blood cells. We hypothesized that the use of a newer device (Spectra Optia) would spare the need for HES. Methods We retrospectively compared granulocyte apheresis with HES (HES group, n = 89) and without HES (non-HES group, n = 36) using Spectra Optia. Results The granulocyte yield was significantly higher in the HES group (7.3 x 10(10) vs. 2.0 x 10, p < 0.01) and was attributed to the difference in collection efficiency (36% vs. 7.7%, p < 0.01). The absolute neutrophil count on the following morning of GT was significantly higher in the HES group than in the non-HES group (2460/mu l vs. 505/mu l, p < 0.01). There were no significant differences in the occurrence of adverse events between the HES and non-HES groups. The renal function was unchanged in both groups after apheresis. Conclusions We demonstrated that the advantage of using HES remained unchanged in granulocyte apheresis using Spectra Optia.
引用
收藏
页码:365 / 370
页数:6
相关论文
共 50 条
  • [31] MONOCYTAPHERESIS FOR PRODUCTION OF DENDRITIC CELL VACCINES; A COMPARISON BETWEEN SPECTRA OPTIA® AND COBE SPECTRA® APHERESIS SYSTEMS
    Berckmans, D.
    Dierickx, D.
    Smith, R.
    [J]. BONE MARROW TRANSPLANTATION, 2014, 49 : S411 - S412
  • [32] Egyptian Experience Comparing Plasma Exchange on the New Optia Spectra Apheresis Machine with the Previous COBE Spectra
    Hussein, E. A.
    El Ansary, M.
    [J]. TRANSFUSION, 2012, 52 : 20A - 21A
  • [33] Comparison of Spectra Optia and COBE Spectra apheresis systems' performances for red blood cell exchange procedures
    Kim, Jaehyup
    Joseph, Ranjit
    Matevosyan, Karen
    Sarode, Ravi
    [J]. TRANSFUSION AND APHERESIS SCIENCE, 2016, 55 (03) : 368 - 370
  • [34] Collection of peripheral blood stem cells in patients and donors using the Amicus® Separator and the Spectra Optia® Apheresis System
    Sputtek, A.
    Schubert, C.
    Peine, S.
    Rowe, A.
    [J]. BONE MARROW TRANSPLANTATION, 2013, 48 : S122 - S122
  • [35] Stem cell apheresis using the Spectra Optia CMNC protocol - Experience of Fundeni Clinical Institute, Bucharest, Romania
    Marculescu, A.
    Calucaroiu, C.
    Tanase, A.
    Varady, Z.
    [J]. BONE MARROW TRANSPLANTATION, 2015, 50 : S336 - S337
  • [36] Successful Stem Cell Apheresis Using Spectra Optia in a 6 kg Child With Atypical Teratoid/Rhabdoid Tumor
    Brust, Patrick
    Schubert, Claudia
    Blohm, Martin
    Winkler, Beate
    [J]. JOURNAL OF PEDIATRIC HEMATOLOGY ONCOLOGY, 2020, 42 (07) : E692 - E695
  • [37] Using heparin 5,000 units in hydroxyethyl starch (Pentastarch) for granulocyte collection
    Lin, J
    Tzeng, C
    Yi, M
    Liu, L
    Lyou, J
    Yung, C
    [J]. TRANSFUSION, 2004, 44 (09) : 42A - 42A
  • [38] HYDROXYETHYL STARCH TO IMPROVE GRANULOCYTE COLLECTION IN LATHAM BLOOD PROCESSOR
    HUESTIS, DW
    WHITE, RF
    PRICE, MJ
    INMAN, M
    [J]. TRANSFUSION, 1975, 15 (06) : 559 - 564
  • [39] SAFE COLLECTION OF PERIPHERAL BLOOD STEM CELLS IN PATIENTS AND DONORS USING THE AMICUS® SEPARATOR AND THE SPECTRA OPTIA® APHERESIS SYSTEM
    Sputtek, A.
    Schubert, C.
    Peine, S.
    Rowe, A. W.
    [J]. VOX SANGUINIS, 2013, 105 : 294 - 295
  • [40] COMPARISON STUDY BETWEEN TWO APHERESIS MACHINES: COBE® SPECTRA VERSUS SPECTRA OPTIA® - A SINGLE CENTER EXPERIENCE
    Soh, T.
    del Mel, S.
    Mah, J.
    Lim, K.
    Tan, L.
    [J]. CYTOTHERAPY, 2013, 15 (04) : S29 - S30