Impact of the use of hydroxyethyl starch in granulocyte apheresis using Spectra Optia

被引:2
|
作者
Yoshihara, Satoshi [1 ,2 ]
Ikemoto, Junko [1 ]
Onomoto, Hitomi [1 ]
Sugiyama, Hiroki [1 ]
Okuda, Noriko [1 ]
Fukunaga, Keiko [2 ]
Yoshihara, Kyoko [1 ,2 ]
Kaida, Katsuji [2 ]
Ikegame, Kazuhiro [2 ]
Tamaki, Hiroya [2 ]
Okada, Masaya [2 ]
Osugi, Yuko [2 ]
Yamahara, Kenichi [1 ]
Higasa, Satoshi [1 ,2 ]
Fujimori, Yoshihiro [1 ,2 ]
机构
[1] Hyogo Coll Med Hosp, Dept Transfus Med & Cellular Therapy, Nishinomiya, Hyogo, Japan
[2] Hyogo Coll Med Hosp, Dept Hematol, Nishinomiya, Hyogo, Japan
关键词
apheresis; collection efficiency; granulocyte transfusion; hydroxyethyl starch; NEUTROPENIC PATIENTS; TRANSFUSIONS; COLLECTION; DONORS; INFECTION; MORTALITY; EFFICACY; INDEX; AREA; RISK;
D O I
10.1111/tme.12795
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives To determine the impact of the use of hydroxyethyl starch (HES) in granulocyte apheresis using Spectra Optia. Background Granulocyte transfusion (GT) is a therapeutic option for neutropenic patients with severe bacterial or fungal infections. Recent studies in emergency medicine have shown the potential risk of using HES, which is routinely used in granulocyte apheresis to increase yield by sedimenting red blood cells. We hypothesized that the use of a newer device (Spectra Optia) would spare the need for HES. Methods We retrospectively compared granulocyte apheresis with HES (HES group, n = 89) and without HES (non-HES group, n = 36) using Spectra Optia. Results The granulocyte yield was significantly higher in the HES group (7.3 x 10(10) vs. 2.0 x 10, p < 0.01) and was attributed to the difference in collection efficiency (36% vs. 7.7%, p < 0.01). The absolute neutrophil count on the following morning of GT was significantly higher in the HES group than in the non-HES group (2460/mu l vs. 505/mu l, p < 0.01). There were no significant differences in the occurrence of adverse events between the HES and non-HES groups. The renal function was unchanged in both groups after apheresis. Conclusions We demonstrated that the advantage of using HES remained unchanged in granulocyte apheresis using Spectra Optia.
引用
收藏
页码:365 / 370
页数:6
相关论文
共 50 条
  • [1] A pilot study on impact of use of medium molecular weight hydroxyethyl starch in granulocyte apheresis using Spectra Optia
    Mandal, Saikat
    Naim, Faran
    Kumar, Ranjan
    Gupta, Sumant
    Gupta, Vibhu Ranjan
    Kathuria, Ishita
    [J]. TRANSFUSION AND APHERESIS SCIENCE, 2022, 61 (05)
  • [2] Granulocyte apheresis donors:: The impact of hydroxyethyl starch on blood coagulation
    Stiegler, M.
    Kolovratova, V.
    Leitner, G.
    Höcker, P.
    [J]. VOX SANGUINIS, 2006, 91 : 213 - 213
  • [3] Improved Efficacy of Granulocyte Collections Obviating the Need for Addition of Hydroxyethyl Starch by Use of the Terumo BCT Spectra Optia Device
    Oikonomopoulou, Dimitra
    Tsonis, Ioannis
    Anyfantis, Vassilis
    Giatra, Chara
    Vardaka, Maria
    Poulopoulou, Zoi
    Bika, Eirini
    Mellios, Zois
    Konstantellos, Ioannis
    Tzenou, Tatiana
    Gigantes, Stavros
    Baltadakis, Ioannis
    Harhalakis, Nicholas
    Karakasis, Dimitrios
    [J]. BONE MARROW TRANSPLANTATION, 2018, 53 : 226 - 227
  • [4] Successful granulocyte apheresis using medium molecular weight hydroxyethyl starch
    Mai Nanya
    Kimiko Yurugi
    Itaru Kato
    Hidefumi Hiramatsu
    Hiroshi Kawabata
    Tadakazu Kondo
    Tomoki Iemura
    Rie Hishida
    Erika Shibutani
    Keiko Matsui
    Yoko Nakagawa
    Norimi Niwa
    Yasunari Kasai
    Joseph M. Roig
    Yasuyuki Arai
    Yasuo Miura
    Akifumi Takaori-Kondo
    Taira Maekawa
    Hideyo Hirai
    [J]. International Journal of Hematology, 2019, 110 : 729 - 735
  • [5] Successful granulocyte apheresis using medium molecular weight hydroxyethyl starch
    Nanya, Mai
    Yurugi, Kimiko
    Kato, Itaru
    Hiramatsu, Hidefumi
    Kawabata, Hiroshi
    Kondo, Tadakazu
    Iemura, Tomoki
    Hishida, Rie
    Shibutani, Erika
    Matsui, Keiko
    Nakagawa, Yoko
    Niwa, Norimi
    Kasai, Yasunari
    Roig, Joseph M.
    Arai, Yasuyuki
    Miura, Yasuo
    Takaori-Kondo, Akifumi
    Maekawa, Taira
    Hirai, Hideyo
    [J]. INTERNATIONAL JOURNAL OF HEMATOLOGY, 2019, 110 (06) : 729 - 735
  • [6] A study on beneficial impact of the use of medium-molecular-weight hydroxyethyl starch in granulocyte apheresis using continuous-flow cell separator Spectra Optia: A retrospective single-center study at a tertiary care oncology center
    Pathak, Amardeep
    Panda, Devasis
    Tejwani, Narender
    Mehta, Anurag
    [J]. ASIAN JOURNAL OF TRANSFUSION SCIENCE, 2024, 18 (01) : 79 - 84
  • [7] Comparison of two apheresis systems for granulocyte collection without hydroxyethyl starch
    Hosoi, Hiroki
    Nakajima, Shiho
    Tsujimoto, Hiroshi
    Murata, Shogo
    Hori, Yoshikazu
    Kuriyama, Kodai
    Mushino, Toshiki
    Matsunami, Misako
    Nishikawa, Akinori
    Kounami, Shinji
    Hanaoka, Nobuyoshi
    Sonoki, Takashi
    [J]. VOX SANGUINIS, 2024, 119 (01) : 62 - 69
  • [8] Optimization of the Spectra Optia for Apheresis of Very Small Subjects
    Donahue, R. E.
    Metzger, M. E.
    Bonifacino, A. C.
    Leitman, S. F.
    Cullis, H. M.
    Lienesch, M.
    Parker, D. M.
    [J]. TRANSFUSION, 2016, 56 : 84A - 84A
  • [9] Granulocyte apheresis with COBE® spectra
    Vrielink, H.
    Van der Meer, P. F.
    Koopman, M. M. W.
    [J]. VOX SANGUINIS, 2008, 95 : 82 - 82
  • [10] Interim analysis of a routine use trial of TPE using the gambro spectra optia, a new generation of therapeutic apheresis platforms
    Theunissen, K.
    Bracke, T.
    Berkmans, D.
    Steward, J.
    Beck, A.
    Smith, R.
    [J]. TRANSFUSION, 2007, 47 (03) : 54A - 54A