A pilot-scale study of dynamic response scenarios for the flexible operation of post-combustion CO2 capture

被引:34
|
作者
Tait, Paul [1 ]
Buschle, Bill [1 ]
Ausner, Ilja [2 ]
Valluri, Prashant [1 ]
Wehrli, Marc [2 ]
Lucquiaud, Mathieu [1 ]
机构
[1] Univ Edinburgh, Sch Engn, Inst Mat & Proc, Sanderson Bldg,Kings Bldg,Mayfield Rd, Edinburgh EH9 3JL, Midlothian, Scotland
[2] Sulzer Chemtech Ltd, Sulzer Allee 48, CH-8404 Winterthur, Switzerland
基金
英国工程与自然科学研究理事会;
关键词
CO2; capture; Post-combustion; NGCC; Flexibility; Dynamic operation; Pilot-plant; CCPILOT100+OPERATING EXPERIENCE; POWER-PLANT; MEA; SOLVENT; VALIDATION; OPTIMIZATION;
D O I
10.1016/j.ijggc.2015.12.009
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The ability to operate flexibly is critical for the future implementation of carbon capture and storage (CCS) in thermal power plants. A dynamic test campaign examines the response of a CO2 absorption/desorption pilot-scale plant to realistic changes in flue gas flow rates and steam supply, representative of the operation of a Natural gas combined cycle (NGCC) plant fitted with post-combustion capture. Five scenarios, demonstrating the operational flexibility that is likely to be encountered in an energy market with significant penetration from intermittent renewables, are presented, with 30% monoethanolamine (MEA) as the absorbing solvent. It complements a wider effort on dynamic modelling of these systems where a lack of dynamic plant data has been reported. The campaign focuses on analysing critical plant parameters of the response of the pilot plant to a gas turbine shutdown, a gas turbine startup and three enhanced operational flexibility scenarios, including two for power output maximisation and one for frequency response with a rapid increase of steam supply to the reboiler. The campaign also demonstrates the use of continuous in situ solvent lean loading measurement with the use of a novel online continuous liquid sensor. It confirms that no significant barriers to flexible operation of amine post-combustion capture are found, although there remains scope for the improvement of plant response. Solvent inventory and circulation times are found to have a significant effect on capture rate during certain dynamic operations. A large solvent inventory increases total circulation times, which can result in additional time being required for the plant to return to steady state following a perturbation. The plant is forced to operate with a non-optimal capture rate while the solvent loading at the absorber inlet stabilises is identified as a potential impact. Use of interim solvent storage and continuous online measurement of solvent CO2 loading, combined with comprehensive knowledge of liquid circulation times and potential mixing effects, are suggested as methods for improving plant response to dynamic operation, thereby increasing CCS plant flexibility. Crown Copyright (C) 2015 Published by Elsevier Ltd.
引用
收藏
页码:216 / 233
页数:18
相关论文
共 50 条
  • [21] Study of novel solvent for CO2 post-combustion capture
    Hadri, Nabil E. L.
    Dang Viet Quang
    Abu-Zahra, Mohammad R. M.
    [J]. CLEAN, EFFICIENT AND AFFORDABLE ENERGY FOR A SUSTAINABLE FUTURE, 2015, 75 : 2268 - 2286
  • [22] Monoethanolamine Degradation during Pilot-Scale Post-combustion Capture of CO2 from a Brown Coal-Fired Power Station
    Reynolds, Alicia J.
    Verheyen, T. Vincent
    Adeloju, Samuel B.
    Chaffee, Alan L.
    Meuleman, Erik
    [J]. ENERGY & FUELS, 2015, 29 (11) : 7441 - 7455
  • [23] A review of degradation and emissions in post-combustion CO2 capture pilot plants
    Buvik, Vanja
    Hoisaeter, Karen K.
    Vevelstad, Sorun J.
    Knuutila, Hanna K.
    [J]. INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2021, 106
  • [24] Pilot scale testing of an advanced solvent in a 0.7 MWe post-combustion CO2 capture unit
    Frimpong, Reynolds A.
    Nikolic, Heather
    Bahr, David
    Kiran, Gopi
    Liu, Kunlei
    [J]. INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2021, 106
  • [25] Evaluation of methods for monitoring MEA degradation during pilot scale post-combustion capture of CO2
    Reynolds, Alicia J.
    Verheyen, T. Vincent
    Adeloju, Samuel B.
    Chaffee, Alan L.
    Meuleman, Erik
    [J]. INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2015, 39 : 407 - 419
  • [26] Dynamic operation of post-combustion CO2 capture in Australian coal-fired power plants
    Bui, Mai
    Gunawan, Indra
    Verheyen, T. Vincent
    Meuleman, Erik
    Feron, Paul
    [J]. 12TH INTERNATIONAL CONFERENCE ON GREENHOUSE GAS CONTROL TECHNOLOGIES, GHGT-12, 2014, 63 : 1368 - 1375
  • [27] Dynamic modeling and simulation of a CO2 absorber column for post-combustion CO2 capture
    Kvamsdal, H. M.
    Jakobsen, J. P.
    Hoff, K. A.
    [J]. CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2009, 48 (01) : 135 - 144
  • [28] Destroying nitrosamines in post-combustion CO2 capture
    Chandan, Payal
    Harrison, Emily
    Honchul, Sarah
    Li, Jiren
    Thompson, Jesse
    Liu, Kunlei
    [J]. 12TH INTERNATIONAL CONFERENCE ON GREENHOUSE GAS CONTROL TECHNOLOGIES, GHGT-12, 2014, 63 : 808 - 813
  • [29] Solvent Selection for Post-Combustion CO2 Capture
    Salazar, Juan
    Diwekar, Urmila
    Joback, Kevin
    Berger, Adam H.
    Bhown, Abhoyjit S.
    [J]. GHGT-11, 2013, 37 : 257 - 264
  • [30] Evaluation of Post-Combustion CO2 Capture Technologies
    Li, Yuan
    Wang, Qimin
    Wang, Peibin
    [J]. RESOURCES AND SUSTAINABLE DEVELOPMENT, PTS 1-4, 2013, 734-737 : 1881 - 1886