Bacterial Contamination of the Vitreous Cavity Associated with Transconjunctival 25-Gauge Microincision Vitrectomy Surgery

被引:14
|
作者
Tominaga, Akiko [1 ]
Oshima, Yusuke [1 ]
Wakabayashi, Taku [1 ]
Sakaguchi, Hirokazu [1 ]
Hori, Yuichi [1 ]
Maeda, Naoyuki [1 ]
机构
[1] Osaka Univ, Sch Med, Dept Ophthalmol, Suita, Osaka 5650871, Japan
关键词
PARS-PLANA VITRECTOMY; ONSET POSTOPERATIVE ENDOPHTHALMITIS; CATARACT-SURGERY; OCULAR SURFACE; CONJUNCTIVAL SAC; OUTCOMES; STAPHYLOCOCCI; PROPHYLAXIS; SCLEROTOMY; PREVENTION;
D O I
10.1016/j.ophtha.2009.09.030
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate differences in the bacterial contamination rates of the vitreous cavity between patients undergoing transconjunctival 25-gauge microincision vitrectomy surgery (MIVS) and conventional 20-gauge pars plana vitrectomy (PPV). Design: Prospective, comparative, consecutive, interventional case series. Participants: Eighty-one eyes of 81 patients who underwent primary vitrectomy and completed perioperative sample collection. Methods: Patients were randomly assigned to 25-gauge MIVS or 20-gauge PPV. Conjunctival swabs were obtained from each patient before and after preoperative administration of topical 0.5% moxifloxacin. Vitreous samples were collected at the beginning and end of surgery. All 4 consecutive specimens from each eye were cultured using direct culturing techniques under aerobic and anaerobic conditions. Main Outcome Measures: The primary outcome measure was the incidence of bacterial contamination of the vitreous cavity at the start and end of vitrectomy. The secondary measures were the incidence of bacterial contamination of the ocular surface and the disinfection rate with preoperative moxifloxacin. Results: Of the 81 eyes (40 eyes in the 25-gauge MIVS group; 41 eyes in the 20-gauge PPV group), the incidences of positive bacterial isolation at the 4 time points of sample collection were 77.5%, 62.3%, 22.5%, and 0% in the former group and 82.9%, 63.4%, 2.4%, and 0% in the latter group. Although the rate of bacterial contamination of the ocular surface significantly (P<0.001) decreased after preoperative moxifloxacin administration in both groups, transconjunctival 25-gauge MIVS had a significantly (P = 0.007) higher incidence of vitreous contamination at the beginning of surgery compared with conventional 20-gauge PPV. The multivariate model showed that 25-gauge MIVS (odds ratio, 11.27; P = 0.027; 95% confidence interval, 1.31-96.79) was the factor prognostic of vitreous contamination at the beginning of surgery. Propionibacterium acnes was identified most often in the vitreous samples (80% of cases), which was consistent with the commensal bacteria isolated from the ocular surface. Conclusions: The higher incidence of bacterial contamination of the vitreous cavity at the beginning of 25-gauge MIVS suggests the increasing risk of direct inoculation of ocular surface flora into the vitreous cavity through the transconjunctival trocar-cannula system compared with conventional 20-gauge PPV. However, vitreous cavity contamination can be eliminated during vitrectomy in most cases. Financial Disclosure(s): Proprietary or commercial disclosure may be found after the references. Ophthalmology 2010;117:811-817 (C) 2010 by the American Academy of Ophthalmology.
引用
收藏
页码:811 / U186
页数:8
相关论文
共 50 条
  • [41] Illuminated curved 25-gauge vitrectomy probe for removal of subsclerotomy vitreous in vitreoretinal surgery
    Chalam, Kakarla V.
    Shah, Gaurav Y.
    Agarwal, Swati
    Gupta, Shailesh K.
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2008, 56 (04) : 331 - 334
  • [42] Faster recovery after 25-gauge microincision vitrectomy surgery than after 20-gauge vitrectomy in patients with proliferative diabetic retinopathy
    Sato, Tatsuhiko
    Emi, Kazuyuki
    Bando, Hajime
    Ikeda, Toshihide
    CLINICAL OPHTHALMOLOGY, 2012, 6 : 1925 - 1930
  • [43] Changes in corneal topography following 25-gauge transconjunctival sutureless vitrectomy and 20-gauge standard vitrectomy
    Okamoto, F
    Sakata, N
    Hiratsuka, K
    Okamoto, C
    Yamane, N
    Oshika, T
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U22 - U22
  • [44] Outcomes and Complications of 25-Gauge Transconjunctival Sutureless Vitrectomy for Proliferative Diabetic Retinopathy
    Ozone, Daisuke
    Hirano, Yoshio
    Ueda, Jiro
    Yasukawa, Tsutomu
    Yoshida, Munenori
    Ogura, Yuichiro
    OPHTHALMOLOGICA, 2011, 226 (02) : 76 - 80
  • [45] Gentamicin-induced macular infarction in transconjunctival sutureless 25-gauge vitrectomy
    Cardascia N.
    Boscia F.
    Furino C.
    Sborgia L.
    International Ophthalmology, 2008, 28 (5) : 383 - 385
  • [46] Fibrovascular Ingrowth After 25-Gauge Transconjunctival Vitrectomy in Proliferative Diabetic Retinopathy
    Rezende, Flavio A.
    Qian, Cynthia X.
    Robert, Marie-Claude
    OPHTHALMIC SURGERY LASERS & IMAGING, 2013, 44 (04) : 405 - 408
  • [47] Incidence of complications in 25-gauge transconjunctival sutureless vitrectomy based on the surgical indications
    Amato, Josh E.
    Akduman, Levent
    OPHTHALMIC SURGERY LASERS & IMAGING, 2007, 38 (02) : 100 - 102
  • [48] Retrospective Comparison of 27-Gauge and 25-Gauge Microincision Vitrectomy Surgery for the Treatment of Primary Rhegmatogenous Retinal Detachment.
    Li, Jie
    Li, Fang
    Liu, Sanmei
    Zhong, Jie
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [49] 25-Gauge Microincision Vitrectomy to Treat Vitreoretinal Disease in Glaucomatous Eyes after Trabeculectomy
    Kunikata, Hiroshi
    Aizawa, Naoko
    Fuse, Nobuo
    Abe, Toshiaki
    Nakazawa, Toru
    JOURNAL OF OPHTHALMOLOGY, 2014, 2014
  • [50] Efficacy of combined 25-gauge microincision vitrectomy, intraocular lens implantation, and posterior capsulotomy
    Aizawa, Naoko
    Kunikata, Hiroshi
    Abe, Toshiaki
    Nakazawa, Toru
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (09): : 1602 - 1607