Differential-pulse voltammetric determination of clenbuterol in bovine urine using a nafion-modified carbon paste electrode

被引:40
|
作者
Moane, S
Smyth, MR
OKeeffe, M
机构
[1] DUBLIN CITY UNIV,SCH CHEM SCI,DUBLIN 9,IRELAND
[2] TEAGASC,NATL FOOD CTR,DUBLIN 15,IRELAND
关键词
clenbuterol; nafion-modified electrode; carbon paste electrode; differential-pulse voltammetry; preconcentration; bovine urine;
D O I
10.1039/an9962100779
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method has been developed for the determination of clenbuterol in bovine urine using differential-pulse voltammetry (DPV), based on the electrochemical behaviour of clenbuterol at a Nafion-modified carbon paste electrode (CPE), Clenbuterol is irreversibly oxidized at high positive potentials, its irreversibility being due to a chemical follow-up reaction which results in a product showing quasi-reversible etectrochemical behaviour at much lower potentials, It is the oxidation peak of this product, arising in acidic media at 0.42 V, which was analysed using DPV, again following the accumulation of clenbuterol at the Nafion-modified CPE, Electrode renewal was achieved by holding the potential at -0.6 V for 120 s in 0.1 mol l(-1) NaOH, The determination of clenbuterol in the presence of interfering compounds present in bovine urine samples was then carried out after a two-step clean-up of the urine involving liquid-liquid extraction followed by a mixed-mode solid-phase extraction procedure, This allowed clenbuterol to be detected down to a level of 1.02 x 10(-9) mol l(-1) in bovine urine extracts.
引用
收藏
页码:779 / 784
页数:6
相关论文
共 50 条
  • [41] Differential Pulse Stripping Voltammetric Determination of Metronidazole with Graphene-Sodium Dodecyl Sulfate Modified Carbon Paste Electrode
    Zhu, Mingfang
    Ye, Hongqing
    Lai, Mushen
    Ye, Jianshan
    Kuang, Jiemin
    Chen, Yuping
    Wang, Jingyue
    Mei, Qianyi
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (05): : 4100 - 4114
  • [42] Ag/TiO2 Nanocomposite Modified Carbon Paste Electrode used to Differential Pulse Voltammetric Determination of Carbamazepine
    Maashhadizadeh, Mohammad Hossein
    Refahati, Reyhaneh
    Amereh, Ehsan
    [J]. ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2013, 5 (03): : 270 - 282
  • [43] Novel Zeolite Modified Carbon Paste Electrode for Differential Pulse Voltammetric Assay of Cyclopentolate hydrochloride
    Al-Qahtani, Salhah D.
    Hameed, Ahmed
    Aljuhani, Enas
    Sayqal, Ali
    Shah, Reem
    Saad, Fawaz
    El-Metwaly, Nashwa M.
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2021, 16 (06): : 1 - 14
  • [44] Anodic differential pulse voltammetric analysis of iodide with a cinchonine-modified carbon paste electrode
    Kwak, MK
    Park, DS
    Won, MS
    Shim, YB
    [J]. ELECTROANALYSIS, 1996, 8 (07) : 680 - 684
  • [45] Anodic Differential Pulse Voltammetric Analysis of Iodide with a Cinchonine-Modified Carbon Paste Electrode
    Department of Chemistry, Pusan National University, Pusan 609-735, Korea, Republic of
    [J]. Electroanalysis, 7 (680-684):
  • [46] Determination of trace amounts of antimony(III) by differential-pulse anodic stripping voltammetry at a phenylfluorone-modified carbon paste electrode
    Khoo, SB
    Zhu, J
    [J]. ANALYST, 1996, 121 (12) : 1983 - 1988
  • [47] Voltammetric Determination of Boron using Cobalt Phthalocyanine Modified Carbon Paste Electrode
    Tunay, Zeki
    Sahin, Ibrahim
    Nakiboglu, Nuri
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2011, 6 (12): : 6628 - 6638
  • [48] Voltammetric determination of imazaquin using polyaniline modified carbon paste electrode (CPE)
    Consolin, N
    Venâncio, EC
    de Medeiros, ES
    Tanimoto, ST
    Machado, SAS
    Mattoso, LHC
    [J]. SENSOR LETTERS, 2006, 4 (01) : 11 - 16
  • [49] Voltammetric Determination of Carbidopa Using a modified Multiwall Carbon Nanotube Paste Electrode
    Mohadesi, Alireza
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (03): : 2430 - 2439
  • [50] VOLTAMMETRIC DETERMINATION OF NITRATE WITH A MODIFIED CARBON-PASTE ELECTRODE
    NEUHOLD, C
    KALCHER, K
    DIEWALD, W
    CAI, XH
    RABER, G
    [J]. ELECTROANALYSIS, 1994, 6 (03) : 227 - 236