Experimental study on the fire resistance of GFRP pultruded tubular columns

被引:15
|
作者
Morgado, T. [1 ]
Correia, J. R. [1 ]
Moreira, A. [1 ]
Branco, F. A. [1 ]
Tiago, C. [1 ]
机构
[1] Univ Lisbon, Inst Super Tecn, ICIST, DECivil, P-1049001 Lisbon, Portugal
关键词
Polymer-matrix composites (PMCs); High-temperature properties; Mechanical testing; Pultrusion; PROTECTION SYSTEMS; PROFILES;
D O I
10.1016/j.compositesb.2014.10.005
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper presents experimental investigations about the fire behaviour of GFRP pultruded columns with square tubular cross-section. The objectives of the study were to evaluate (i) the efficacy of passive (calcium silicate (CS) boards) and active (water-cooling) systems in providing fire protection to GFRP pultruded columns; and the effects of (ii) the number of sides exposed to fire; and (iii) the service load level on the GFRP columns' fire response. To this end, fire resistance tests were performed on 1.5 m long GFRP columns, subjected to two different load levels corresponding to axial shortenings of L/1500 and L/750 (L being the span), and simultaneously exposed to fire, in either one or three sides, according to the time-temperature curve defined in ISO 834. Results obtained were analysed regarding the thermal and mechanical responses of the GFRP columns (unprotected and protected), namely in terms of the evolution of axial and transverse displacements, the failure modes and the fire resistance. It was possible to conclude that for one-side exposure, water-cooling is the most effective protection, particularly with flowing water, providing more than 120 min of fire resistance. For three-sides exposure, the fire resistance of the different solutions tested was severely reduced, namely that of the water-cooling systems, which provided fire resistances of only about 20 min, regardless of using flowing water; for this type of exposure, the best performance was provided by the CS board protection, with about 40 min of fire resistance. The results obtained in this study draw the attention to the technical advantages of adopting a building architecture in which the GFRP columns are integrated in the facades and embedded in partition walls, preventing the columns from being exposed to fire in three sides. As expected, the load level increase caused a reduction of fire resistance, due to the higher stresses developed in the sections' walls and to the GFRP strength decrease with temperature. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:201 / 211
页数:11
相关论文
共 50 条
  • [1] Experimental study on the fire resistance of GFRP pultruded tubular beams
    Morgado, T.
    Correia, J. R.
    Silvestre, N.
    Branco, F. A.
    COMPOSITES PART B-ENGINEERING, 2018, 139 : 106 - 116
  • [2] Simulation of fire resistance behaviour of pultruded GFRP columns
    Morgado, Tiago
    Silvestre, Nuno
    Correia, Joao R.
    THIN-WALLED STRUCTURES, 2019, 135 : 521 - 536
  • [3] Experimental study of the quasi-static axial compressive resistance of pultruded GFRP composite stub columns
    de Lazzari, Joao Alfredo
    Gonilha, Jose
    Correia, Joao R.
    Silvestre, Nuno
    CONSTRUCTION AND BUILDING MATERIALS, 2024, 449
  • [4] Buckling of GFRP pultruded columns
    Russo, S
    COMPOSITES IN CONSTRUCTION, 2001, : 113 - 118
  • [5] Experimental research on pultruded concrete-filled GFRP tubular short columns externally strengthened with CFRP
    Guo, Zhan
    Xue, Xiaolei
    Ye, Mengya
    Chen, Yu
    Li, Zhihui
    COMPOSITE STRUCTURES, 2021, 255 (255)
  • [6] Experimental and numerical investigation of pultruded GFRP circular hollow tubular columns under concentric and eccentric loading
    Higgoda, Thumitha Mandula
    Elchalakani, Mohamed
    Kimiaei, Mehrdad
    Wittek, Adam
    Yang, Bo
    COMPOSITE STRUCTURES, 2023, 304
  • [7] The Material Heterogeneity Effect on the Local Resistance of Pultruded GFRP Columns
    Zhu, Yongcheng
    Gribniak, Viktor
    Ding, Chaofeng
    Zhu, Hua
    Chen, Baiqi
    MATERIALS, 2024, 17 (01)
  • [8] Experimental and numerical simulation of reinforced concrete-filled GFRP pultruded tubular columns under axial compression
    Jing, Chenggui
    Zhao, Lin
    Chen, Shuang
    Wu, Tong
    Chen, Zongping
    Liu, Bing
    CONSTRUCTION AND BUILDING MATERIALS, 2025, 462
  • [9] Experimental study on axial compression behavior of square pultruded GFRP tubular stub column
    Xing, Zhiquan
    Zhu, Yao
    Liu, Qingan
    Hui, David
    Chen, Yu
    Chen, Wei
    CASE STUDIES IN CONSTRUCTION MATERIALS, 2024, 20
  • [10] Numerical modelling of the thermal response of pultruded GFRP tubular profiles subjected to fire
    Morgado, T.
    Silvestre, N.
    Correia, J. R.
    Branco, F. A.
    Keller, T.
    COMPOSITES PART B-ENGINEERING, 2018, 137 : 202 - 216