Experimental study of the quasi-static axial compressive resistance of pultruded GFRP composite stub columns

被引:2
|
作者
de Lazzari, Joao Alfredo [1 ,2 ]
Gonilha, Jose [1 ]
Correia, Joao R. [1 ]
Silvestre, Nuno [2 ]
机构
[1] Univ Lisbon, Inst Super Tecn, CERIS, Ave Rovisco Pais 1, P-1049001 Lisbon, Portugal
[2] Univ Lisbon, IDMEC, Inst Super Tecn, Ave Rovisco Pais 1, P-1049001 Lisbon, Portugal
关键词
Pultruded profiles; Crushing; Delamination; Axially compressed members; Experimental tests; Design guidelines; REINFORCED POLYMER COMPOSITES; STABILITY; BEHAVIOR; FAILURE;
D O I
10.1016/j.conbuildmat.2024.138252
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents an experimental investigation on the crushing behaviour of full-section pultruded glass fibre reinforced polymer (pGFRP) profiles with 11 different cross-section geometries, encompassing 6 different shapes (C, I, W, SHS, RHS, L sections). Quasi-static axial compressive tests were conducted on stub column specimens, mitigating second-order and buckling effects. The crushing phenomenon of the pGFRP profiles was investigated regarding the following aspects: (i) influence of end surface flatness, (ii) analysis of load/stress vs . strain behaviour, (iii) definition of relative slenderness thresholds to avoid buckling, (iv) determination of full-section compressive strength for various cross-sections, and (v) correlation of geometrical and mechanical experimental data. The results show that when the relative slenderness was limited to 0.7, no buckling occurred, and the load was uniformly applied across the section of the profiles. Additionally, for the different cross-section geometries, the estimates of resistance to crushing of pGFRP stub columns obtained from compressive coupon tests were non- conservative: in average, the resistance to crushing of full-section stub columns was around 60% of those estimates. Unlike the coupon tests, the stub columns presented complex failure with multiple damage modes, which were attributed to the non-uniformity of material properties across the section walls. The correlation analysis provided insights into the linear dependency of the full-section compressive strength with geometrical and material properties. Surprisingly, shear strengths were shown to play a more relevant role in the crushing phenomenon of stub columns than compressive strength. The findings of this study will contribute to the drafting of improved design guidelines able to estimate more accurately (and likely more reliably) the compressive resistance to crushing.
引用
收藏
页数:21
相关论文
共 50 条
  • [1] Experimental study on the fire resistance of GFRP pultruded tubular columns
    Morgado, T.
    Correia, J. R.
    Moreira, A.
    Branco, F. A.
    Tiago, C.
    COMPOSITES PART B-ENGINEERING, 2015, 69 : 201 - 211
  • [2] Experimental study on axial compression behavior of square pultruded GFRP tubular stub column
    Xing, Zhiquan
    Zhu, Yao
    Liu, Qingan
    Hui, David
    Chen, Yu
    Chen, Wei
    CASE STUDIES IN CONSTRUCTION MATERIALS, 2024, 20
  • [3] Experimental study of axial compressive performance of UHPC-encased CFST composite stub columns
    Wu Q.
    Xu Z.
    Yuan H.
    Qin Z.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2023, 44 (12): : 183 - 193
  • [4] Axial Compression Behaviours of Pultruded GFRP-Wood Composite Columns
    Qi, Yujun
    Xie, Lei
    Bai, Yu
    Liu, Weiqing
    Fang, Hai
    SENSORS, 2019, 19 (04)
  • [5] Experimental study on quasi-static indentation damage resistance of composite laminates
    Luo, Liang
    Zhang, Zuoguang
    Li, Min
    Shen, Zhen
    Yang, Shengchun
    Fuhe Cailiao Xuebao/Acta Materiae Compositae Sinica, 2007, 24 (03): : 154 - 159
  • [6] A Study of Energy Absorption Performances of Pultruded Composites under Quasi-Static Compressive Loadings
    Masran, S. H.
    Ismail, A. E.
    Marian, M. F.
    4TH MECHANICAL AND MANUFACTURING ENGINEERING, PTS 1 AND 2, 2014, 465-466 : 662 - +
  • [7] Axial compressive performance of steel reinforced fibrous concrete composite stub columns: Experimental and theoretical study
    Memarzadeh, Armin
    Nematzadeh, Mahdi
    STRUCTURES, 2021, 34 : 2455 - 2475
  • [8] Crushing behaviour of composite hemispherical shells subjected to quasi-static axial compressive load
    Saleh, MA
    Mahdi, E
    Hamouda, AMS
    Khalid, YA
    COMPOSITE STRUCTURES, 2004, 66 (1-4) : 487 - 493
  • [9] Quasi-static indentation response of pedestrian bridge multicellular pultruded GFRP deck panels
    Sutherland, L. S.
    Sa, M. F.
    Correia, J. R.
    Soares, C. Guedes
    Gomes, A.
    Silvestre, N.
    CONSTRUCTION AND BUILDING MATERIALS, 2016, 118 : 307 - 318
  • [10] Experimental studies on the quasi-static axial crushing of steel columns filled with aluminium foam
    Seitzberger, M
    Rammerstorfer, FG
    Gradinger, R
    Degischer, HP
    Blaimschein, M
    Walch, C
    INTERNATIONAL JOURNAL OF SOLIDS AND STRUCTURES, 2000, 37 (30) : 4125 - 4147