Value of somatostatin receptor scintigraphy for preoperative localization of carcinoids

被引:29
|
作者
Kisker, O [1 ]
Weinel, RJ [1 ]
Geks, J [1 ]
Zacara, F [1 ]
Joseph, K [1 ]
Rothmund, M [1 ]
机构
[1] UNIV HOSP MARBURG,DEPT NUCL MED,D-35033 MARBURG,GERMANY
关键词
D O I
10.1007/s002689900025
中图分类号
R61 [外科手术学];
学科分类号
摘要
Most carcinoid primary tumors are small and do not cause symptoms until complications (e.g. intestinal obstruction) or symptoms and signs of the carcinoid syndrome occur. Therefore in most cases an assessment of the primary tumor and its metastases must be performed. To determine the value of somatostatin receptor scintigraphy (SRS) for localizing carcinoid tumors, we compared the results of SRS with those obtained with computed tomography (CT) and ultrasonography (US) in 22 patients who had not undergone surgery for removal of the primary tumor. We could not find an advantage of SRS over CT and US for detecting the primary lesions. Tumors > 2 cm in diameter were regularly detected using all methods. SRS was not superior to CT or US for the detection of liver metastases. SRS showed the liver metastases in 16 of 18 patients, whereas CT and US detected liver metastases in all patients. For localization of extrahepatic abdominal and extraabdominal metastases (lymph nodes, bone), whole-body SRS showed an advantage over CT and US. We conclude that SRS is not superior to CT or US for localization of primary carcinoid tumors or liver metastases, although it did prove successful for visualizing extrahepatic and extraabdominal tumor spread. Additionally, SRS is useful for identifying receptor-positive metastases that map be treated by somatostatin analogs. Thus SRS should be performed in patients with a known carcinoid tumor, except those with an appendiceal carcinoid measuring < 1 cm in diameter.
引用
收藏
页码:162 / 167
页数:6
相关论文
共 50 条
  • [41] Novel Use of Somatostatin Receptor Scintigraphy in Localization of Focal Congenital Hyperinsulinism: Promising but Fallible
    Dutta, Sourabh
    Venkataseshan, Sundaram
    Bal, Chandrasekhar
    Rao, K. L. N.
    Gupta, Kirti
    Bhattacharya, Anish
    Narang, Anil
    JOURNAL OF PEDIATRIC ENDOCRINOLOGY & METABOLISM, 2009, 22 (10): : 965 - 969
  • [42] ENDOSCOPIC ULTRASONOGRAPHY (EUS) AND SOMATOSTATIN-RECEPTOR-SCINTIGRAPHY (SRS) FOR THE LOCALIZATION OF INSULINOMAS AND GASTRINOMAS
    ZIMMER, T
    LIEHR, RM
    STOLZEL, U
    FETT, U
    BADER, M
    RIECKEN, EO
    WIEDENMANN, B
    GASTROENTEROLOGY, 1994, 106 (04) : A331 - A331
  • [43] Positive somatostatin receptor scintigraphy correlates with the presence of somatostatin receptor subtype 2
    John, M
    Meyerhof, W
    Richter, D
    Waser, B
    Schaer, JC
    Scherubl, H
    BoeseLandgraf, J
    Neuhaus, P
    Ziske, C
    Molling, K
    Riecken, EO
    Reubi, JC
    Wiedenmann, B
    GUT, 1996, 38 (01) : 33 - 39
  • [44] Hypertrophic pulmonary osteoarthropathy on bone scintigraphy and somatostatin receptor scintigraphy
    Meristoudis, Georgios
    Ilias, Ioannis
    Giannakopoulos, Vasilios
    PNEUMON, 2021, 34 (03)
  • [45] Is There an Additional Value of Somatostatin Receptor Subtype 2A Immunohistochemistry Over Somatostatin Receptor Scintigraphy in Predicting Gastroenteropancreatic Neuroendocrine Tumor Response?
    Van Adrichem, R.
    Kamp, K.
    Van Deurzen, C.
    Biermann, K.
    Feelders, R. A.
    Kwekkeboom, D.
    Hofland, L. J.
    De Herder, W.
    NEUROENDOCRINOLOGY, 2015, 102 (1-2) : 135 - 135
  • [46] Value of somatostatin receptor scintigraphy: A prospective study in gastrinoma of its effect on clinical management
    Termanini, B
    Gibril, F
    Reynolds, JC
    Doppman, JL
    Chen, CC
    Stewart, CA
    Sutliff, VE
    Jensen, RT
    GASTROENTEROLOGY, 1997, 112 (02) : 335 - 347
  • [47] Clinical value of 24-hour delayed imaging in somatostatin receptor scintigraphy for meningioma
    Klutmann, S
    Bohuslavizki, KH
    Tietje, N
    Kröger, S
    Behnke, A
    Brenner, W
    Mester, J
    Henze, E
    Clausen, M
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (08) : 1246 - 1251
  • [48] The additional value of somatostatin receptor scintigraphy during preoperative staging in patients with non-functioning pancreatic neuroendocrine tumors. A clinical guidance
    Jilesen, Anneke
    Hoefnagel, Sanne
    Busch, Olivier
    Bennink, Roelof
    Gouma, Dirk
    Nieveen, Els
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [49] Preferential localization of regional metastases from gastroenteropancreatic endocrine tumors with somatostatin-receptor scintigraphy
    MacGillivray, DC
    Mumtaz, MA
    Kurtzman, SH
    Spencer, RP
    Weiner, RE
    Malchoff, CD
    ARCHIVES OF SURGERY, 1996, 131 (12) : 1338 - 1342
  • [50] SOMATOSTATIN RECEPTOR IMAGING IN PATIENTS WITH NEUROENDOCRINE TUMORS - PREOPERATIVE AND POSTOPERATIVE SCINTIGRAPHY AND INTRAOPERATIVE USE OF A SCINTILLATION DETECTOR
    AHLMAN, H
    TISELL, LE
    WANGBERG, B
    NILSSON, O
    FORSSELLARONSSON, E
    FJALLING, M
    SEMINARS IN ONCOLOGY, 1994, 21 (05) : 21 - 28