Ag nanoparticles outperform Au nanoparticles for the use as label in electrochemical point-of-care sensors

被引:16
|
作者
Beck, Franziska [1 ]
Horn, Carina [2 ]
Baeumner, Antje J. [1 ]
机构
[1] Univ Regensburg, Inst Analyt Chem Chemo & Biosensors, D-93043 Regensburg, Germany
[2] Roche Diagnost, D-68305 Mannheim, Germany
关键词
Electrochemical biosensor; Silver nanoparticle; Gold nanoparticle; Blood analysis; DPV;
D O I
10.1007/s00216-021-03288-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Electrochemical immunosensors enable rapid analyte quantification in small sample volumes, and have been demonstrated to provide high sensitivity and selectivity, simple miniaturization, and easy sensor production strategies. As a point-of-care (POC) format, user-friendliness is equally important and most often not combinable with high sensitivity. As such, we demonstrate here that a sequence of metal oxidation and reduction, followed by stripping via differential pulse voltammetry (DPV), provides lowest limits of detection within a 2-min automatic measurement. In exchanging gold nanoparticles (AuNPs), which dominate in the development of POC sensors, with silver nanoparticles (AgNPs), not only better sensitivity was obtained, but more importantly, the assay protocol could be simplified to match POC requirements. Specifically, we studied both nanoparticles as reporter labels in a sandwich immunoassay with the blood protein biomarker NT-proBNP. For both kinds of nanoparticles, the dose-response curves easily covered the ng center dot mL(-1) range. The mean standard deviation of all measurements of 17% (n >= 4) and a limit of detection of 26 ng center dot mL(-1) were achieved using AuNPs, but their detection requires addition of HCl, which is impossible in a POC format. In contrast, since AgNPs are electrochemically less stable, they enabled a simplified assay protocol and provided even lower LODs of 4.0 ng center dot mL(-1) in buffer and 4.7 ng center dot mL(-1) in human serum while maintaining the same or even better assay reliability, storage stability, and easy antibody immobilization protocols. Thus, in direct comparison, AgNPs clearly outperform AuNPs in desirable POC electrochemical assays and should gain much more attention in the future development of such biosensors.
引用
收藏
页码:475 / 483
页数:9
相关论文
共 50 条
  • [41] Electrochemical Biosensors for Point-of-care Applications
    Karunakaran, Chandran
    Karthikeyan, Murugesan
    Kumar, Marimuthu Dhinesh
    Kaniraja, Ganesan
    Bhargava, Kalpana
    [J]. DEFENCE SCIENCE JOURNAL, 2020, 70 (05) : 549 - 556
  • [42] Electrochemical biosensors for point-of-care applications
    Karunakaran C.
    Karthikeyan M.
    Kumar M.D.
    Kaniraja G.
    Bhargava K.
    [J]. Def. Sci. J., 2020, 5 (549-556): : 549 - 556
  • [43] Electronic and electrochemical viral detection for point-of-care use: A systematic review
    Monteill, Solen
    Casson, Alexander J.
    Jones, Samuel T.
    [J]. PLOS ONE, 2021, 16 (09):
  • [44] Synthesis of Au core Au/Ag alloy shell nanoparticles using branched Au nanoparticles as seeds
    Tang, Xinling
    Tsuji, Masaharu
    [J]. CRYSTENGCOMM, 2011, 13 (01): : 72 - 76
  • [45] Inappropriate Off-label Use of a Qualitative, Point-of-care hCG Device
    Nerenz, Robert D.
    Gronowski, Ann M.
    Grenache, David G.
    [J]. WESTERN JOURNAL OF EMERGENCY MEDICINE, 2017, 18 (02) : 324 - 325
  • [46] Metal Organic Frameworks Based Wearable and Point-of-Care Electrochemical Sensors for Healthcare Monitoring
    Theyagarajan, K.
    Kim, Young-Joon
    [J]. Biosensors, 2024, 14 (10):
  • [47] Label-Free Electrochemical Thrombin Aptasensor Based on Ag Nanoparticles Modified Electrode
    Suprun, Elena
    Shumyantseva, Victoria
    Rakhmetova, Svetlana
    Voronina, Svetlana
    Radko, Sergey
    Bodoev, Nikolay
    Archakov, Alexander
    [J]. ELECTROANALYSIS, 2010, 22 (12) : 1386 - 1392
  • [48] Nanoparticles in electrochemical sensors for environmental monitoring
    Rassaei, Liza
    Amiri, Mandana
    Cirtiu, Ciprian Mihai
    Sillanpaeae, Markus
    Marken, Frank
    Sillanpaeae, Mika
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2011, 30 (11) : 1704 - 1715
  • [49] Application of nanoparticles in electrochemical sensors and biosensors
    Luo, XL
    Morrin, A
    Killard, AJ
    Smyth, MR
    [J]. ELECTROANALYSIS, 2006, 18 (04) : 319 - 326
  • [50] A dual-electrode label-free immunosensor based on in situ prepared Au-MoO3-Chi/porous graphene nanoparticles for point-of-care detection of cholangiocarcinoma
    Cotchim, Suparat
    Kongkaew, Supatinee
    Thavarungkul, Panote
    Kanatharana, Proespichaya
    Limbut, Warakorn
    [J]. TALANTA, 2024, 272