Impact of Room Location on UV-C Irradiance and UV-C Dosage and Antimicrobial Effect Delivered by a Mobile UV-C Light Device

被引:40
|
作者
Boyce, John M. [1 ,2 ]
Farrel, Patricia A. [3 ]
Towle, Dana [3 ]
Fekieta, Renee [1 ]
Aniskiewicz, Michael [1 ]
机构
[1] Yale New Haven Med Ctr, Qual Improvement Support Serv, 20 York St, New Haven, CT 06504 USA
[2] Yale Univ, Yale New Haven Hosp, Sch Med, New Haven, CT USA
[3] Yale New Haven Med Ctr, Dept Lab Med, 20 York St, New Haven, CT 06504 USA
来源
关键词
IN-HOSPITAL ROOMS; DECONTAMINATION; DISINFECTION; PATHOGENS; RADIATION;
D O I
10.1017/ice.2016.35
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
OBJECTIVE. To evaluate ultraviolet C (UV-C) irradiance, UV-C dosage, and antimicrobial effect achieved by a mobile continuous UV-C device. DESIGN. Prospective observational study. METHODS. We used 6 UV light sensors to determine UV-C irradiance (W/cm(2)) and UV-C dosage (mu Wsec/cm(2)) at various distances from and orientations relative to the UV-C device during 5-minute and 15-minute cycles in an ICU room and a surgical ward room. In both rooms, stainless-steel disks inoculated with methicillin-resistant Staphylococcus aureus (MRSA), vancomycin-resistant Enterococcus (VRE), and Clostridium difficile spores were placed next to sensors, and UV-C dosages and log(10) reductions of target organisms achieved during 5-minute and 15-minute cycles were determined. Mean irradiance and dosage readings were compared using ANOVA. RESULTS. Mean UV-C irradiance was nearly 1.0E-03W/cm(2) in direct sight at a distance of 1.3m (4 ft) from the device but was 1.12E-05W/cm(2) on a horizontal surface in a shaded area 3.3m (10 ft) from the device (P<.001). Mean UV-C dosages received by UV-C sensors located at different distances and orientation relative to the device varied significantly during 5-minute cycles and during 15-minute cycles (P<. 001). Log(10) reductions ranged from > 4 to 1-3 for MRSA, > 4 to 1-2 for VRE and > 4 to 0 log(10) for C. difficile spores, depending on the distance from, and orientation relative to, the device with 5-minute and 15-minute cycles. CONCLUSION. UV-C irradiance, dosage, and antimicrobial effect received from a mobile UV-C device varied substantially based on location in a room relative to the UV-C device.
引用
收藏
页码:667 / 672
页数:6
相关论文
共 50 条
  • [21] Comparison of Persulfate/UV-C and Peroxymonosulfate/UV-C Processes for COD and TOC Removal in Urban Wastewater Treatment
    Kaykioglu, Gul
    Uckan, Mir Servan
    JOURNAL OF WATER CHEMISTRY AND TECHNOLOGY, 2023, 45 (04) : 332 - 342
  • [23] Sanitation of Mushroom (Agaricus bisporus) with UV-C Light
    Ozcoz, B.
    Barriobero, J.
    Roth, E.
    Lopez, R.
    Urbina, C.
    XXVIII INTERNATIONAL HORTICULTURAL CONGRESS ON SCIENCE AND HORTICULTURE FOR PEOPLE (IHC2010): INTERNATIONAL SYMPOSIUM ON POSTHARVEST TECHNOLOGY IN THE GLOBAL MARKET, 2012, 934 : 1229 - 1234
  • [24] Evaluating UV-C Sensitivity of Calonectria pseudonaviculata in Model Buffer Solution Using a UV-C Light-Emitting-Diode System
    Ghimire, Bhawana
    Pendyala, Brahmaiah
    Patras, Ankit
    Baysal-Gurel, Fulya
    PLANT DISEASE, 2024, 108 (09) : 2663 - 2667
  • [25] Physiological Responses of Scenedesmus quadricauda (Chlorophyceae) to UV-A and UV-C Light
    Kovacik, Jozef
    Klejdus, Borivoj
    Backor, Martin
    PHOTOCHEMISTRY AND PHOTOBIOLOGY, 2010, 86 (03) : 612 - 616
  • [26] UV-C, S2O82-/UV-C and H2O2/UV-C TREATMENT OF AQUEOUS BISPHENOL A RESULTS IN DIFFERENT ACUTE TOXICITY PATTERNS
    Olmez-Hanci, T.
    Arslan-Alaton, I.
    Dursun, D.
    Genc, B.
    PROCEEDINGS OF THE 13TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2013,
  • [27] Advances in UV-A and UV-C LEDs and the applications they enable
    Kumar, M.
    LIGHT-EMITTING DEVICES, MATERIALS, AND APPLICATIONS, 2019, 10940
  • [28] Room Temperature UV-C Lasers with Nitride Microdisks on Silicon
    Selles, J.
    Brimont, C.
    Cassabois, G.
    Guillet, T.
    Gayral, B.
    Mexis, M.
    Semond, F.
    Roland, I.
    Zeng, Y.
    Checoury, X.
    Boucaud, P.
    2015 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2015,
  • [29] Nanoscale and quantum engineering of III-nitride heterostructures for high efficiency UV-C and far UV-C optoelectronics
    Liu, Xianhe
    Pandey, Ayush
    Mi, Zetian
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2021, 60 (11)
  • [30] Conductivity effect of UV-c radiation on solid insulators
    Dervos, CT
    Skafidas, PD
    CONFERENCE RECORD OF THE 1998 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, VOLS 1 AND 2, 1998, : 338 - 342