Radiosurgery of multiple brain metastases with single-isocenter dynamic conformal arcs (SIDCA)

被引:81
|
作者
Huang, Yimei [1 ]
Chin, Karen [1 ]
Robbins, Jared R. [1 ]
Kim, Jinkoo [1 ]
Li, Haisen [1 ]
Amro, Hanan [1 ]
Chetty, Indrin J. [1 ]
Gordon, James [1 ]
Ryu, Samuel [1 ]
机构
[1] Henry Ford Hlth Syst, Dept Radiat Oncol, Detroit, MI 48202 USA
关键词
Stereotactic radiosurgery; Multiple brain metastases; Single-isocenter; VOLUMETRIC MODULATED ARC; BENIGN INTRACRANIAL TUMORS; STEREOTACTIC RADIOSURGERY; THERAPY; SURVIVAL; PHOTONS; INDEX;
D O I
10.1016/j.radonc.2014.05.009
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To propose single-isocenter dynamic conformal arcs (SIDCA), a novel technique for radiosurgery of multiple brain metastases, and to compare SIDCA with volumetric modulated arc therapy (VMAT) and multiple-isocenter dynamic conformal arcs (MIDCA) for plan quality. Methods and materials: SIDCA, MIDCA, and VMAT plans were created on 6 patients with 3-5 metastases. Plans were evaluated using Radiation Therapy Oncology Group conformity index (RCI), Paddick conformity index (PCI), gradient index (GI), volumes that received more than 100% (V-100%), 50% (V-50%), 25% (V-25%) and 10% (V-10%) of prescription dose, total monitor units (MUs), and delivery time (DT). Results: SIDCA achieved conformal plans (RCI = 1.38 +/- 0.12, PCI = 0.72 +/- 0.06) with steep dose fall-off (GI = 3.97 +/- 0.51). MIDCA plans had comparable plan quality and MUs as SIDCA, but 52% longer DT. The VMAT plans had better conformity (RCI = 1.15 +/- 0.09, p < 0.01 and PCI = 0.86 +/- 0.06, p < 0.01) than SIDCA, worse GI (4.34 +/- 0.46, p < 0.01), higher V-25% (13 = 0.05) and V-10% (13 = 0.02), 49% less MUs and 46% shorter DT. Conclusions: All three techniques achieved conformal plans with steep dose fall-off from targets. SIDCA plans had similar plan quality as MIDCA but more efficient to delivery. SIDCA plans had lower peripheral dose spread than VMAT; VMAT plans had better conformity and faster delivery time than SIDCA. (C) 2014 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:128 / 132
页数:5
相关论文
共 50 条
  • [41] SINGLE-ISOCENTER FRAMELESS INTENSITY-MODULATED STEREOTACTIC RADIOSURGERY FOR SIMULTANEOUS TREATMENT OF MULTIPLE BRAIN METASTASES: CLINICAL EXPERIENCE
    Nath, Sameer K.
    Lawson, Joshua D.
    Simpson, Daniel R.
    VanderSpek, Lauren
    Wang, Jia-Zhu
    Alksne, John F.
    Ciacci, Joseph
    Mundt, Arno J.
    Murphy, Kevin T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (01): : 91 - 97
  • [42] Frameless single-isocenter intensity modulated stereotactic radiosurgery for simultaneous treatment of multiple intracranial metastases
    Lau, Steven K. M.
    Zhao, Xiao
    Carmona, Ruben
    Knipprath, Erik
    Simpson, Daniel R.
    Nath, Sameer K.
    Kim, Gwe-Ya
    Hattangadi, Jona A.
    Chen, Clark C.
    Murphy, Kevin T.
    TRANSLATIONAL CANCER RESEARCH, 2014, 3 (04) : 383 - 390
  • [43] Evaluation of multiple factors affecting normal brain dose in single-isocenter multiple target radiosurgery
    Yuan, Yu
    Thomas, Evan M.
    Clark, Grant A.
    Markert, James M.
    Fiveash, John B.
    Popple, Richard A.
    JOURNAL OF RADIOSURGERY AND SBRT, 2018, 5 (02): : 131 - 144
  • [44] Clinical Outcomes of Single Isocenter Frameless Radiosurgery for Multiple Brain Metastases
    Lau, S.
    Zhao, X.
    Knipprath, E.
    Simpson, D. R.
    Chen, C. C.
    Murphy, K. T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S273 - S273
  • [45] A Single-isocenter Technique for Frameless Intensity-modulated Stereotactic Radiosurgery for Multiple Brain Metastases: Clinical Experience and Outcomes
    Murph, K. T.
    Nath, S. K.
    Simpson, D. R.
    VanderSpek, L.
    Alksne, J. F.
    Mundt, A. J.
    Lawson, J. D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S237 - S238
  • [46] Evaluation of RapidArc vs. Static Intensity-Modulated Radiosurgery in the Single-Isocenter Approach for Multiple Brain Metastases
    Wang, J.
    Pawlicki, T.
    Rice, R.
    Mundt, A.
    Murphy, K.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [47] Brain Stereotactic Radiosurgery Planning Using the Single-Isocenter Dynamic-Arc Technique
    Chang, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E700 - E700
  • [48] Single isocenter Multitarget Radiosurgery and multiple brain metastases: Preliminary Experience
    Ciervide, R.
    Lopez, M.
    Marti, J.
    Hernando, O.
    Alvarez, B.
    Montero, A.
    Sanchez, E.
    Garcia-Aranda, M.
    Valero, J.
    Chen, X.
    Alonso, R.
    Rossi, K.
    Canadillas, C.
    Fernandez-Leton, P.
    Rubio, C.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S891 - S892
  • [49] Single Isocenter Volumetric Modulated Arc Radiosurgery for Multiple Brain Metastases
    Chang-Halpenny, C. N.
    Rahimian, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E582 - E583
  • [50] Practical Considerations for Single Isocenter LINAC Radiosurgery of Multiple Brain Metastases
    Meeks, Sanford L.
    Mercado, Catherine E.
    Popple, Richard A.
    Agazaryan, Nzhde
    Kaprealian, Tania
    Fiveash, John B.
    Tenn, Stephen
    PRACTICAL RADIATION ONCOLOGY, 2022, 12 (03) : 195 - 199