Parallel imaging methods for phased array MRI

被引:2
|
作者
Zhang, BD
Wang, WD
Song, XY
Zu, DL
Chen, GF
Bao, SL [1 ]
机构
[1] Peking Univ, Beijing Key Lab Med Phys & Engn, Res Ctr Tumor Diag & Therapeut Phys, Inst Heavy Ion Phys, Beijing 100871, Peoples R China
[2] Gen Hosp PLA, Beijing 100085, Peoples R China
关键词
MRI; radiofrequency; phased-array;
D O I
10.1080/10020070312331343590
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Two parallel methods for magnetic resonance imaging (MRI) using radio frequency (RF) phased array surface coils, named spatial local Fourier encoding (SLFE) and spatial RF encoding (SRFE), are presented. The MR signals are acquired from separate channels across the coils, each of which covers a sub-FOV (field-of-view) in a parallel fashion, and the acquired data are combined to form an image of entire FOV. These two parallel encoding techniques can accelerate MR imaging greatly, yet associated artifact may appear, although the SLFE is an effective image reconstruction method which can reduce the localized artifact in some degrees. By the SRFE, RF coil array can be utilized for spatial encoding through a specialized coil design. The images are acquired in a snapshot with a high signal-to-noise ratio (SNR) without the costly gradient system, resulting in great saving of cost. Both mutual induction and aliasing effect of adjacent coils are critical to the success of SRFE. The strategies of inverse source problem and wavelet transform (WT) can be employed to eliminate them. The results simulated by MATLAB are reported.
引用
收藏
页码:307 / 310
页数:4
相关论文
共 50 条
  • [21] Quantitative Phased Array Modeling and Imaging
    Schmerr, Lester W., Jr.
    2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2015,
  • [22] An eight-channel, nonoverlapping phased array coil with capacitive decoupling for parallel MRI at 3 T
    Von Morze, Cornelius
    Tropp, James
    Banerjee, Suchandrima
    Xu, Duan
    Karpodinis, Kostas
    Carvajal, Lucas
    Hess, Christopher P.
    Mukherjee, Pratik
    Majumdar, Sharmila
    Vigneron, Daniel B.
    CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2007, 31B (01) : 37 - 43
  • [23] A four-element phased array coil for high resolution and parallel MR imaging of the knee
    Kwok, WE
    Zhong, JH
    You, ZG
    Seo, G
    Totterman, SMS
    MAGNETIC RESONANCE IMAGING, 2003, 21 (09) : 961 - 967
  • [24] MRI Parallel Imaging
    Yanasak, N.
    Goerner, F.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [25] Parallel computing in phased array radar system simulation
    Xu, Lei
    Wu, Si-Liang
    Li, Hai
    Beijing Ligong Daxue Xuebao/Transaction of Beijing Institute of Technology, 2008, 28 (06): : 517 - 520
  • [26] Mouse MRI using phased-array coils
    Gareis, Daniel
    Wichmann, Tobias
    Lanz, Titus
    MeIkus, Gerd
    Horn, Michael
    Jakob, Peter M.
    NMR IN BIOMEDICINE, 2007, 20 (03) : 326 - 334
  • [27] MRI feedback control for phased array prostate hyperthermia
    Hutchinson, EB
    Dahleh, M
    Hynynen, K
    1996 IEEE ULTRASONICS SYMPOSIUM, PROCEEDINGS, VOLS 1 AND 2, 1996, : 1285 - 1288
  • [28] Focused synthetic phased array for subsurface imaging
    Graham, WJ
    IEEE ANTENNAS AND PROPAGATION SOCIETY INTERNATIONAL SYMPOSIUM - ANTENNAS: GATEWAYS TO THE GLOBAL NETWORK, VOLS 1-4, 1998, : 986 - 989
  • [29] Plane Wave Imaging Using Phased Array
    Volker, Arno
    40TH ANNUAL REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION: INCORPORATING THE 10TH INTERNATIONAL CONFERENCE ON BARKHAUSEN NOISE AND MICROMAGNETIC TESTING, VOLS 33A & 33B, 2014, 1581 : 124 - 131
  • [30] Imaging analysis of photorefractive phased array beamforming
    Kriehn, G
    Kiruluta, A
    Silveira, PEX
    Weaver, S
    Wagner, K
    RADAR PROCESSING, TECHNOLOGY, AND APPLICATIONS III, 1998, 3462 : 196 - 208