A biomechanical case study on the optimal orthodontic force on the maxillary canine tooth based on finite element analysis

被引:60
|
作者
Wu, Jian-lei [1 ]
Liu, Yun-feng [1 ]
Peng, Wei [1 ]
Dong, Hui-yue [2 ]
Zhang, Jian-xing [3 ]
机构
[1] Zhejiang Univ Technol, Key Lab E&M, Minist Educ & Zhejiang Prov, Hangzhou 310014, Zhejiang, Peoples R China
[2] Zhejiang Univ, Sch Mech Engn, Key Lab Adv Mfg Technol Zhejiang Prov, Hangzhou 310027, Zhejiang, Peoples R China
[3] Zhejiang Prov Peoples Hosp, Dept Stomatol, Hangzhou 310014, Zhejiang, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Biomechanics; Optimal orthodontic force; Finite element analysis; Periodontal ligament; HUMAN PERIODONTAL-LIGAMENT; ROOT RESORPTION; HYDROSTATIC-PRESSURE; MECHANICAL RESPONSES; MOVEMENT; MODEL; SIMULATION; BEHAVIOR; TEETH;
D O I
10.1631/jzus.B1700195
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Excessive forces may cause root resorption and insufficient forces would introduce no effect in orthodontics. The objective of this study was to investigate the optimal orthodontic forces on a maxillary canine, using hydrostatic stress and logarithmic strain of the periodontal ligament (PDL) as indicators. Finite element models of a maxillary canine and surrounding tissues were developed. Distal translation/tipping forces, labial translation/tipping forces, and extrusion forces ranging from 0 to 300 g (100 g=0.98 N) were applied to the canine, as well as the force moment around the canine long axis ranging from 0 to 300 g center dot mm. The stress/strain of the PDL was quantified by nonlinear finite element analysis, and an absolute stress range between 0.47 kPa (capillary pressure) and 12.8 kPa (80% of human systolic blood pressure) was considered to be optimal, whereas an absolute strain exceeding 0.24% (80% of peak strain during canine maximal moving velocity) was considered optimal strain. The stress/strain distributions within the PDL were acquired for various canine movements, and the optimal orthodontic forces were calculated. As a result the optimal tipping forces (40-44 g for distal-direction and 28-32 g for labial-direction) were smaller than the translation forces (130-137 g for distal-direction and 110-124 g for labial-direction). In addition, the optimal forces for labialdirection motion (110-124 g for translation and 28-32 g for tipping) were smaller than those for distal-direction motion (130-137 g for translation and 40-44 g for tipping). Compared with previous results, the force interval was smaller than before and was therefore more conducive to the guidance of clinical treatment. The finite element analysis results provide new insights into orthodontic biomechanics and could help to optimize orthodontic treatment plans.
引用
收藏
页码:535 / 546
页数:12
相关论文
共 50 条
  • [31] A three-dimensional finite element analysis of the effect of archwire characteristics on the self-ligating orthodontic tooth movement of the canine
    Cai, Yongqing
    TECHNOLOGY AND HEALTH CARE, 2019, 27 : S195 - S204
  • [32] The Influence of the Periodontal Breakdown over the Amount of Orthodontic Force Reaching the Dental Pulp and NVB During Orthodontic Movements-A Biomechanical Finite Element Analysis
    Moga, Radu-Andrei
    Olteanu, Cristian Doru
    Delean, Ada Gabriela
    JOURNAL OF CLINICAL MEDICINE, 2025, 14 (06)
  • [33] Finite element analysis of a newly designed miniplate for orthodontic anchorage in the maxillary anterior region
    Neves, Alexandre Maeda
    do Nascimento, Monikelly do Carmo Chagas
    Cardoso, Mauricio de Almeida
    Meloti, Fernand
    Sliva, Ertty
    An, Tien-Li
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2022, 162 (05) : 656 - 667
  • [34] Effects of different designs of orthodontic clear aligners on the maxillary central incisors in the tooth extraction cases: a biomechanical study
    Meng, Xuehuan
    Wang, Chunjuan
    Xu, Wenjie
    Wang, Rui
    Zheng, Leilei
    Wang, Chao
    Aversa, Raffaella
    Fan, Yubo
    BMC ORAL HEALTH, 2023, 23 (01)
  • [35] Effects of different designs of orthodontic clear aligners on the maxillary central incisors in the tooth extraction cases: a biomechanical study
    Xuehuan Meng
    Chunjuan Wang
    Wenjie Xu
    Rui Wang
    Leilei Zheng
    Chao Wang
    Raffaella Aversa
    Yubo Fan
    BMC Oral Health, 23
  • [36] Biomechanical analysis of the lumbar spine on facet joint force and intradiscal pressure - a finite element study
    Ching-Sung Kuo
    Hsuan-Teh Hu
    Ruey-Mo Lin
    Kuo-Yuan Huang
    Po-Chun Lin
    Zheng-Cheng Zhong
    Mu-Lin Hseih
    BMC Musculoskeletal Disorders, 11
  • [37] Biomechanical analysis of the lumbar spine on facet joint force and intradiscal pressure - a finite element study
    Kuo, Ching-Sung
    Hu, Hsuan-Teh
    Lin, Ruey-Mo
    Huang, Kuo-Yuan
    Lin, Po-Chun
    Zhong, Zheng-Cheng
    Hseih, Mu-Lin
    BMC MUSCULOSKELETAL DISORDERS, 2010, 11
  • [38] Effect of material variation on the biomechanical behaviour of orthodontic fixed appliances: a finite element analysis
    Papageorgiou, Spyridon N.
    Keilig, Ludger
    Hasan, Istabrak
    Jaeger, Andreas
    Bourauel, Christoph
    EUROPEAN JOURNAL OF ORTHODONTICS, 2016, 38 (03) : 300 - 307
  • [39] Analysis of stress in periodontium associated with orthodontic tooth movement: a three dimensional finite element analysis
    Jain, Ankita
    Prasantha, G. S.
    Mathew, Silju
    Sabrish, Sharanya
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2021, 24 (16) : 1841 - 1853
  • [40] Biomechanical performance of an immature maxillary central incisor after revitalization: a finite element analysis
    Bucchi, C.
    Marce-Nogue, J.
    Galler, K. M.
    Widbiller, M.
    INTERNATIONAL ENDODONTIC JOURNAL, 2019, 52 (10) : 1508 - 1518