The Potential and Limitations of Mobile Health and Insertable Cardiac Monitors in the Detection of Atrial Fibrillation in Cryptogenic Stroke Patients: Preliminary Results From the REMOTE Trial

被引:1
|
作者
Wouters, Femke [1 ,2 ]
Gruwez, Henri [1 ,2 ,3 ,4 ]
Vranken, Julie [1 ,2 ]
Vanhaen, Dimitri [1 ,2 ]
Daelman, Bo [1 ,2 ]
Ernon, Ludovic [5 ]
Mesotten, Dieter [1 ,6 ]
Vandervoort, Pieter [1 ,2 ,3 ]
Verhaert, David [3 ]
机构
[1] Hasselt Univ, Fac Med & Life Sci, Mobile Hlth Unit, Limburg Clin Res Ctr, Hasselt, Belgium
[2] Ziekenhuis Oost Limburg, Dept Future Hlth, Genk, Belgium
[3] Ziekenhuis Oost Limburg, Dept Cardiol, Genk, Belgium
[4] Univ Leuven, Dept Cardiovasc Sci, Leuven, Belgium
[5] Ziekenhuis Oost Limburg, Dept Neurol, Genk, Belgium
[6] Ziekenhuis Oost Limburg, Dept Anesthesiol, Genk, Belgium
来源
关键词
atrial fibrillation; cryptogenic stroke; insertable cardiac monitor (ICM); mobile health; cardiac rhythm monitoring; ISCHEMIC-STROKE; RISK-FACTOR; SUBTYPES;
D O I
10.3389/fcvm.2022.848914
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
AimThis paper presents the preliminary results from the ongoing REMOTE trial. It aims to explore the opportunities and hurdles of using insertable cardiac monitors (ICMs) and photoplethysmography-based mobile health (PPG-based mHealth) using a smartphone or smartwatch to detect atrial fibrillation (AF) in cryptogenic stroke and transient ischemic attack (TIA) patients. Methods and ResultsCryptogenic stroke or TIA patients (n = 39) received an ICM to search for AF and were asked to use a blinded PPG-based mHealth application for 6 months simultaneously. They were randomized to smartphone or smartwatch monitoring. In total, 68,748 1-min recordings were performed using PPG-based mHealth. The number of mHealth recordings decreased significantly over time in both smartphone and smartwatch groups (p < 0.001 and p = 0.002, respectively). Insufficient signal quality was more frequently observed in smartwatch (43.3%) compared to smartphone recordings (17.8%, p < 0.001). However, when looking at the labeling of the mHealth recordings on a patient level, there was no significant difference in signal quality between both groups. Moreover, the use of a smartwatch resulted in significantly more 12-h periods (91.4%) that were clinically useful compared to smartphone users (84.8%) as they had at least one recording of sufficient signal quality. Simultaneously, continuous data was collected from the ICMs, resulting in approximately 6,660,000 min of data (i.e., almost a 100-fold increase compared to mHealth). The ICM algorithm detected AF and other cardiac arrhythmias in 10 and 19 patients, respectively. However, these were only confirmed after adjudication by the remote monitoring team in 1 (10%) and 5 (26.3%) patients, respectively. The confirmed AF was also detected by PPG-based mHealth. ConclusionBased on the preliminary observations, our paper illustrates the potential as well as the limitations of PPG-based mHealth and ICMs to detect AF in cryptogenic stroke and TIA patients in four elements: (i) mHealth was able to detect AF in a patient in which AF was confirmed on the ICM; (ii) Even state-of-the-art ICMs yielded many false-positive AF registrations; (iii) Both mHealth and ICM still require physician revision; and (iv) Blinding of the mHealth results impairs compliance and motivation.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Incidence and Duration of Atrial Fibrillation Among a Large, Real-World Population of Cryptogenic Stroke Patients with Insertable Cardiac Monitors
    Richards, Mark
    Ferreira, Scott W.
    Nichols, Allan
    Rogers, John D.
    Koehler, Jodi L.
    Sarkar, Shantanu
    Warman, Eduardo N.
    Ziegler, Paul D.
    STROKE, 2015, 46
  • [22] Validation of a Clinical Risk Score for Predicting Atrial Fibrillation in Cryptogenic Stroke Patients With Insertable Cardiac Monitors: Insights From the CRYSTAL AF Study
    Passman, Rod S.
    Ziegler, Paul D.
    Kwong, Calvin
    Crawford, Michael H.
    Koehler, Jodi L.
    Zhao, Susan X.
    STROKE, 2018, 49
  • [23] Insertable Cardiac Event Recorder in Detection of Atrial Fibrillation After Cryptogenic Stroke An Audit Report
    Etgen, Thorleif
    Hochreiter, Manfred
    Mundel, Markus
    Freudenberger, Thomas
    STROKE, 2013, 44 (07) : 2007 - 2009
  • [24] Predictors for detection of atrial fibrillation in cryptogenic stroke patients: insights from insertable cardiac monitor data in the CRYSTAL AF study
    Assar, M.
    Thijs, V.
    Brachmann, J.
    Morillo, C.
    Passman, R.
    Sanna, T.
    Bernstein, R.
    Diener, H.
    Di Lazzaro, V.
    Rymer, M.
    EUROPEAN HEART JOURNAL, 2014, 35 : 1109 - 1109
  • [25] Predictors for detection of atrial fibrillation in cryptogenic stroke patients: Insights from insertable cardiac monitor data in the CRYSTAL AF study
    Thijs, V
    Brachmann, J.
    Morillo, C.
    Passman, R.
    Sanna, T.
    Bernstein, R.
    Diener, H.
    Di Lazzaro, V
    Rymer, M.
    Assar, M.
    INTERNATIONAL JOURNAL OF STROKE, 2014, 9 : 25 - 25
  • [26] Detection of subclinical atrial fibrillation after cryptogenic stroke using implantable cardiac monitors
    Ungar, Andrea
    Pescini, Francesca
    Rafanelli, Martina
    De Angelis, Maria Vittoria
    Faustino, Massimiliano
    Tomaselli, Caterina
    Petrone, Alfredo
    Forleo, Giovanni
    Morani, Giovanni
    Forlivesi, Stefano
    Molon, Giulio
    Adami, Alessandro
    Maines, Massimiliano
    Stegagno, Chiara
    Poggesi, Anna
    Pantoni, Leonardo
    EUROPEAN JOURNAL OF INTERNAL MEDICINE, 2021, 92 : 86 - 93
  • [27] Use of an Insertable Cardiac Monitor to Detect Atrial Fibrillation is Cost Effective in Patients with Cryptogenic Stroke
    Diamantopoulos, Alex
    Sawyer, Laura
    Sungher, Dilpreet
    Lip, Gregory
    Witte, Klaus
    Reynolds, Mathew R.
    Fauchier, Laurent
    Thijs, Vincent
    Brown, Ben
    Quiroz, Maria E.
    Diener, Hans-Christoph
    STROKE, 2015, 46
  • [28] Cost-effectiveness of an insertable cardiac monitor to detect atrial fibrillation in patients with cryptogenic stroke
    Diamantopoulos, Alex
    Sawyer, Laura M.
    Lip, Gregory Y. H.
    Witte, Klaus K.
    Reynolds, Matthew R.
    Fauchier, Laurent
    Thijs, Vincent
    Brown, Ben
    Angulo, Maria E. Quiroz
    Diener, Hans-Christoph
    INTERNATIONAL JOURNAL OF STROKE, 2016, 11 (03) : 302 - 312
  • [29] Cost-effectiveness of an insertable cardiac monitor to detect atrial fibrillation in patients with cryptogenic stroke
    Sawyer, Laura M.
    Witte, Klaus K.
    Reynolds, Matthew R.
    Mittal, Suneet
    Jones, Frank W. Grimsey
    Rosemas, Sarah C.
    Ziegler, Paul D.
    Kaplons, Rachelle E.
    Yaghi, Shadi
    JOURNAL OF COMPARATIVE EFFECTIVENESS RESEARCH, 2021, 10 (02) : 127 - 141
  • [30] Incidence of atrial fibrillation among patients with an embolic stroke of undetermined source: Insights from insertable cardiac monitors
    Verma, Nishant
    Ziegler, Paul D.
    Liu, Shufeng
    Passman, Rod S.
    INTERNATIONAL JOURNAL OF STROKE, 2019, 14 (02) : 146 - 153