The Potential and Limitations of Mobile Health and Insertable Cardiac Monitors in the Detection of Atrial Fibrillation in Cryptogenic Stroke Patients: Preliminary Results From the REMOTE Trial

被引:1
|
作者
Wouters, Femke [1 ,2 ]
Gruwez, Henri [1 ,2 ,3 ,4 ]
Vranken, Julie [1 ,2 ]
Vanhaen, Dimitri [1 ,2 ]
Daelman, Bo [1 ,2 ]
Ernon, Ludovic [5 ]
Mesotten, Dieter [1 ,6 ]
Vandervoort, Pieter [1 ,2 ,3 ]
Verhaert, David [3 ]
机构
[1] Hasselt Univ, Fac Med & Life Sci, Mobile Hlth Unit, Limburg Clin Res Ctr, Hasselt, Belgium
[2] Ziekenhuis Oost Limburg, Dept Future Hlth, Genk, Belgium
[3] Ziekenhuis Oost Limburg, Dept Cardiol, Genk, Belgium
[4] Univ Leuven, Dept Cardiovasc Sci, Leuven, Belgium
[5] Ziekenhuis Oost Limburg, Dept Neurol, Genk, Belgium
[6] Ziekenhuis Oost Limburg, Dept Anesthesiol, Genk, Belgium
来源
关键词
atrial fibrillation; cryptogenic stroke; insertable cardiac monitor (ICM); mobile health; cardiac rhythm monitoring; ISCHEMIC-STROKE; RISK-FACTOR; SUBTYPES;
D O I
10.3389/fcvm.2022.848914
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
AimThis paper presents the preliminary results from the ongoing REMOTE trial. It aims to explore the opportunities and hurdles of using insertable cardiac monitors (ICMs) and photoplethysmography-based mobile health (PPG-based mHealth) using a smartphone or smartwatch to detect atrial fibrillation (AF) in cryptogenic stroke and transient ischemic attack (TIA) patients. Methods and ResultsCryptogenic stroke or TIA patients (n = 39) received an ICM to search for AF and were asked to use a blinded PPG-based mHealth application for 6 months simultaneously. They were randomized to smartphone or smartwatch monitoring. In total, 68,748 1-min recordings were performed using PPG-based mHealth. The number of mHealth recordings decreased significantly over time in both smartphone and smartwatch groups (p < 0.001 and p = 0.002, respectively). Insufficient signal quality was more frequently observed in smartwatch (43.3%) compared to smartphone recordings (17.8%, p < 0.001). However, when looking at the labeling of the mHealth recordings on a patient level, there was no significant difference in signal quality between both groups. Moreover, the use of a smartwatch resulted in significantly more 12-h periods (91.4%) that were clinically useful compared to smartphone users (84.8%) as they had at least one recording of sufficient signal quality. Simultaneously, continuous data was collected from the ICMs, resulting in approximately 6,660,000 min of data (i.e., almost a 100-fold increase compared to mHealth). The ICM algorithm detected AF and other cardiac arrhythmias in 10 and 19 patients, respectively. However, these were only confirmed after adjudication by the remote monitoring team in 1 (10%) and 5 (26.3%) patients, respectively. The confirmed AF was also detected by PPG-based mHealth. ConclusionBased on the preliminary observations, our paper illustrates the potential as well as the limitations of PPG-based mHealth and ICMs to detect AF in cryptogenic stroke and TIA patients in four elements: (i) mHealth was able to detect AF in a patient in which AF was confirmed on the ICM; (ii) Even state-of-the-art ICMs yielded many false-positive AF registrations; (iii) Both mHealth and ICM still require physician revision; and (iv) Blinding of the mHealth results impairs compliance and motivation.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Insertable cardiac monitors for detection of atrial fibrillation after cryptogenic stroke: a meta-analysis
    Lu, Yue
    Diao, Shan-shan
    Huang, Shuang-jiao
    Zhao, Jie-ji
    Ye, Meng-fan
    Yao, Fei-rong
    Kong, Yan
    Xu, Zhuan
    NEUROLOGICAL SCIENCES, 2021, 42 (10) : 4139 - 4148
  • [2] Insertable cardiac monitors for detection of atrial fibrillation after cryptogenic stroke: a meta-analysis
    Yue Lu
    Shan-shan Diao
    Shuang-jiao Huang
    Jie-ji Zhao
    Meng-fan Ye
    Fei-rong Yao
    Yan Kong
    Zhuan Xu
    Neurological Sciences, 2021, 42 : 4139 - 4148
  • [3] Use of insertable cardiac monitors for the detection of atrial fibrillation in patients with cryptogenic stroke in the United States is cost-effective
    Maervoet, J.
    Bossers, N.
    Borge, R. P., Jr.
    Hilpert, S. Thompson
    van Engen, A.
    Smala, A.
    JOURNAL OF MEDICAL ECONOMICS, 2019, 22 (11) : 1221 - 1234
  • [4] HIGH RISK OF RECURRENT STROKE IN CRYPTOGENIC STROKE PATIENTS WITH INSERTABLE CARDIAC MONITORS WITH OR WITHOUT A DIAGNOSIS OF ATRIAL FIBRILLATION
    Bharucha, Ronak
    Pasha, Arham
    Troy, Jordan
    Moyer, Ross
    Korada, Sai Krishna C.
    Abdulla, Khaled
    Drago, Thomas
    Palatnic, Leonard
    Mannan, Abdul
    Siva, Ajay
    Curtis, Anne B.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 83 (13) : 40 - 40
  • [5] Evaluation of a clinical score for predicting atrial fibrillation in cryptogenic stroke patients with insertable cardiac monitors: results from the CRYSTAL AF study
    Zhao, Susan X.
    Ziegler, Paul D.
    Crawford, Michael H.
    Kwong, Calvin
    Koehler, Jodi L.
    Passman, Rod S.
    THERAPEUTIC ADVANCES IN NEUROLOGICAL DISORDERS, 2019, 12
  • [6] Predictors for Early Atrial Fibrillation Detection Among Cryptogenic Stroke Patients with Insertable Cardiac Monitors: A Single-center Experience
    Asaithambi, Ganesh
    Monita, Jane E.
    Hanson, Sandra K.
    STROKE, 2017, 48
  • [7] Predictors for Early Atrial Fibrillation Detection Among Cryptogenic Stroke Patients with Insertable Cardiac Monitors: A Single-Center Experience
    Asaithambi, Ganesh
    Monita, Jane
    Hanson, Sandra
    NEUROLOGY, 2017, 88
  • [8] Prevalence of atrial fibrillation with insertable cardiac monitors in cryptogenic stroke: A single-center experience
    Asaithambi, Ganesh
    Monita, Jane E.
    Annamalai, M. Ramu
    Ho, Bridget M.
    Marino, Emily H.
    Hanson, Sandra K.
    JOURNAL OF ELECTROCARDIOLOGY, 2018, 51 (06) : 973 - 976
  • [9] Cryptogenic stroke and atrial fibrillation in a real-world population: the role of insertable cardiac monitors
    Maria Vittoria De Angelis
    Vincenzo Di Stefano
    Raffaella Franciotti
    Nanda Furia
    Enrico Di Girolamo
    Marco Onofrj
    Massimiliano Faustino
    Scientific Reports, 10
  • [10] Cost-effectiveness of insertable cardiac monitors for diagnosis of atrial fibrillation in cryptogenic stroke in Australia
    Thijs, Vincent
    Witte, Klaus K.
    Guarnieri, Carmel
    Makino, Koji
    Tilden, Dominic
    Gillespie, John
    Huynh, Marianne
    JOURNAL OF ARRHYTHMIA, 2021, 37 (04) : 1077 - 1085