The optimization of coal on-line analysis system based on signal-to-noise ratio evaluation

被引:14
|
作者
Li, JiaTong [1 ]
Jia, WenBao [1 ,2 ]
Hei, DaQian [1 ,2 ]
Cai, PingKun [1 ]
Cheng, Can [1 ]
Tang, Yajun [1 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Coll Mat Sci & Engn, Dept Nucl Sci & Engn, Nanjing 211106, Jiangsu, Peoples R China
[2] Collaborat Innovat Ctr Radiat Med, Jiangsu Higher Educ Inst, Suzhou 215000, Peoples R China
基金
中国国家自然科学基金;
关键词
Signal-to-noise ratio (SNR); MCNP simulation; PGNAA; System optimization; NATIONAL-INSTITUTE; INSTRUMENT; STANDARDS;
D O I
10.1007/s10967-018-6173-x
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the present study, the coal on-line analysis system is optimized, and the signal-to-noise ratio (SNR) is quantified and set as the evaluation criterion for device optimization. 3cm lead with 3cm polyethylene is set as moderator, and 13cm lead is for a better shielding. Besides, the neutron generator is set at the center of device, and 72cm is set as the better distance of axis between neutron generator and detector. Finally, by comparing with the previous experimental results, the Mean Absolute Percentage Error of element with the value less than 1% is improved after device optimization by SNR evaluation.
引用
收藏
页码:1279 / 1286
页数:8
相关论文
共 50 条
  • [21] Measurement of Signal-to-Noise Ratio and Signal-to-Noise and Distortion Ratio Using Histogram Test in Time Domain Analysis
    Jain, Manish
    Sharma, Prakash Chandra
    Tiwari, Pradeep Kumar
    Gupta, Rohit Kumar
    SMART SYSTEMS: INNOVATIONS IN COMPUTING (SSIC 2021), 2022, 235 : 403 - 410
  • [22] Analysis of Responsivity and Signal-to-Noise Ratio in PEPT
    Zhou Quan
    Guo Shu-Xu
    Li Zhao-Han
    Song Jing-Yi
    Chang Yu-Chun
    CHINESE PHYSICS LETTERS, 2012, 29 (11)
  • [23] Analysis of signal-to-noise ratio in optical receivers
    Bielecki, Z
    Kolosowski, W
    Sedek, E
    Borejko, M
    ELECTRICAL ENGINEERING AND ELECTROMAGNETICS VI, 2003, 5 : 255 - 264
  • [24] An analysis of the signal-to-noise ratio of a current amplifier
    Brovchenko, VG
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2000, 43 (01) : 57 - 62
  • [25] AMBER performances: signal-to-noise ratio analysis
    Malbet, F
    Chelli, A
    Petrov, R
    INTERFEROMETRY IN OPTICAL ASTRONOMY, PTS 1 AND 2, 2000, 4006 : 233 - 242
  • [26] An analysis of the signal-to-noise ratio of a current amplifier
    V. G. Brovchenko
    Instruments and Experimental Techniques, 2000, 43 : 57 - 62
  • [27] THE USE OF SIMULATION FOR THE OPTIMIZATION OF THE SIGNAL-TO-NOISE RATIO IN CYCLIC ACTIVATION-ANALYSIS
    ALMUGRABI, MA
    SPYROU, NM
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1987, 110 (01): : 67 - 77
  • [28] Hybridizing Particle Swarm Optimization with Signal-to-Noise Ratio for numerical optimization
    Lin, Whei-Min
    Gow, Hong-Jey
    Tsai, Ming-Tang
    EXPERT SYSTEMS WITH APPLICATIONS, 2011, 38 (11) : 14086 - 14093
  • [29] Signal-to-noise ratio evaluation radiography with synchrotron radiation
    Fabbri, S
    Taibi, A
    Longo, R
    Marziani, M
    Olivo, A
    Pani, S
    Tuffanelli, A
    Gambaccini, M
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (22): : 4093 - 4105
  • [30] Signal-to-noise ratio in MRI
    Redpath, TW
    BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (847): : 704 - 707