Localization of partial discharges using UHF sensors in power transformers

被引:0
|
作者
Shen, Z. B. [1 ]
El-Saadany, E. F. [1 ]
机构
[1] Univ Waterloo, Dept Elect & Comp Engn, Waterloo, ON N2L 3G1, Canada
来源
2006 POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-9 | 2006年
关键词
partial discharge (PD); ultra high frequency (UHF) signal; UHF sensor; power transformer; dielectric material; monitoring system; simulation; condition monitoring;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Transformer failure is usually triggered by external events such as lightning strikes, switching transients, or short circuits. However, susceptibility to these events is usually due to some incipient weakness in the insulation system, which may be detected at an earlier stage by monitoring partial discharge activities. Usually, PDs are detected acoustically, chemically, or electrically. The acoustic and chemical PD detection technology has been successfully used on power transformers for many years. However, in this paper, The PD's UHF phenomenon in power transformers is simulated by MATLAB and FEMLAB, and the monitoring method of using UHF sensors is analyzed. Furthermore, a new PD localization method using three URF sensors is also proposed.
引用
收藏
页码:2660 / +
页数:2
相关论文
共 50 条
  • [1] Partial Discharge Localization in Transformers Using UHF Sensors
    Sinaga, H. H.
    Phung, B. T.
    Ao, P. L.
    Blackburn, T. R.
    2011 ELECTRICAL INSULATION CONFERENCE (EIC), 2011, : 64 - 68
  • [2] Optimized Arrival Time Determination of UHF Pulses for Localization of Partial Discharges in Power Transformers
    Azirani, M. Akbari
    Ariannik, M.
    Werle, P.
    Akbari, A.
    2018 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (IEEE CEIDP), 2018, : 522 - 526
  • [3] Localization Accuracy of Partial Discharges in Power Transformers
    Win, Su Su
    Adam, Benjamin
    Tenbohlen, Stefan
    2018 15TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING/ELECTRONICS, COMPUTER, TELECOMMUNICATIONS AND INFORMATION TECHNOLOGY (ECTI-CON), 2018, : 197 - 200
  • [4] Partial Discharge Localization in Transformers Using Monopole and Log-Spiral UHF Sensors
    Sinaga, H. H.
    Phung, B. T.
    Blackburn, T. R.
    2012 IEEE 10TH INTERNATIONAL CONFERENCE ON THE PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS (ICPADM), 2012,
  • [5] Optimal frequency selection for detection of partial discharges in power transformers using the UHF measurement technique
    Azirani, Mohammad Akbari
    Ariannik, Mohamadreza
    Werle, Peter
    Akbari, Asghar
    MEASUREMENT, 2021, 172
  • [6] Partial discharge monitoring for power transformers using UHF sensors Part 1: Sensors and signal interpretation
    Judd, MD
    Yang, L
    Hunter, IBB
    IEEE ELECTRICAL INSULATION MAGAZINE, 2005, 21 (02) : 5 - 14
  • [7] Enhancing the Accuracy of Partial Discharge Localization in Power Transformers Using the UHF Measurement Technique
    Azirani, Mohammad Akbari
    Ariannik, Mohamadreza
    Werle, Peter
    Akbari, Asghar
    2019 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2019, : 58 - 62
  • [8] Optimisation of a Sensor for Onsite Detection of Partial Discharges in Power Transformers by the UHF Method
    Lopez-Roldan, J.
    Tang, T.
    Gaskin, M.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2008, 15 (06) : 1634 - 1639
  • [9] Partial Discharge Localization in Transformers Using UHF Detection Method
    Sinaga, H. H.
    Phung, B. T.
    Blackburn, T. R.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2012, 19 (06) : 1891 - 1900
  • [10] Partial discharge monitoring for power transformers using UHF sensors - part 2: Field experience
    Judd, MD
    Yang, L
    Hunter, IBB
    IEEE ELECTRICAL INSULATION MAGAZINE, 2005, 21 (03) : 5 - 13