Evaluation of fan-pattern spray nozzle wear using scanning electron microscopy

被引:0
|
作者
Krause, CR
Reichard, DL
Zhu, H
Brazee, RD
Ozkan, HE
Fox, RD
机构
[1] USDA ARS, Applicat Technol Res Unit, OARDC, Wooster, OH 44691 USA
[2] Ohio State Univ, Coll Food Agr & Environm Sci, Dept Food Agr & Biol Engn, Columbus, OH 43210 USA
关键词
pesticide application; environmental concerns; application technology;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Worn nozzles on spray equipment severely affect the efficiency of crop management systems while causing unnecessary pesticide contamination of non target areas. Scanning electron microscopy (SEM) that has been applied for direct measurement of pesticide deposition, was used to observe worn and unused brass and stainless steel fan-pattern spray nozzles. Wear and other changes were observed in both nozzle materials. Scanning electron microscopy can provide nozzle manufacturers with greater insight and needed information on nozzle mechanics to improve performance. More reliable delivery of pesticide spray should enhance integrated pest and disease management and crop protection for growers.
引用
收藏
页码:8 / 11
页数:4
相关论文
共 50 条
  • [21] Breakdown pattern identification in high temperature dielectric films using scanning electron microscopy (SEM)
    Ul-Haq, S
    Raju, G
    2003 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2003, : 265 - 268
  • [22] Intraspecific variation in spermoderm pattern of tribe Acacieae (Mimosoideae) using scanning electron microscopy techniques
    Alam, Fakhre
    Ahmad, Mushtaq
    Zafar, Muhammad
    Shinwari, Muhammad I.
    Luqman, Muhammad
    Novruz, Novruzov E.
    Sultana, Shazia
    Ullah, Farhat
    Ahmad, Manzoor
    MICROSCOPY RESEARCH AND TECHNIQUE, 2019, 82 (02) : 114 - 121
  • [23] EVALUATION OF DISTRACTION OSTEOGENESIS BY SCANNING ELECTRON-MICROSCOPY
    GANEY, TM
    KLOTCH, DW
    SLATERHAASE, AS
    SASSE, J
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 1994, 111 (03) : 265 - 272
  • [24] Commentary on the use of scanning electron microscopy in evaluation of craniosynostosis
    Arnaud, E
    Marchac, D
    JOURNAL OF CRANIOFACIAL SURGERY, 1998, 9 (01) : 39 - 39
  • [25] Scanning electron microscopy evaluation of aligner fit on teeth
    Mantovani, Edoardo
    Castroflorio, Enrico
    Rossini, Gabriele
    Garino, Francesco
    Cugliari, Giovanni
    Deregibus, Andrea
    Castroflorio, Tommaso
    ANGLE ORTHODONTIST, 2018, 88 (05) : 596 - 601
  • [26] EVALUATION OF ARTIFICIAL MINERALIZATION OF WOOD BY SCANNING ELECTRON MICROSCOPY
    Mamonova, Miroslava
    Murinova, Tereza
    Mec, Pavel
    ACTA FACULTATIS XYLOLOGIAE ZVOLEN, 2015, 57 (01): : 15 - 23
  • [27] Evaluation of collagen gel microstructure by scanning electron microscopy
    A. G. Pogorelov
    I. I. Selezneva
    Bulletin of Experimental Biology and Medicine, 2010, 150 : 153 - 156
  • [28] Evaluation of Collagen Gel Microstructure by Scanning Electron Microscopy
    Pogorelov, A. G.
    Selezneva, I. I.
    BULLETIN OF EXPERIMENTAL BIOLOGY AND MEDICINE, 2010, 150 (01) : 153 - 156
  • [29] Comparison of studies using a Rau detector in scanning electron microscopy and scanning optical microscopy
    Hoffmeister, H
    Palma, B
    Kohl, H
    EUROPEAN JOURNAL OF CELL BIOLOGY, 1997, 74 : 69 - 69
  • [30] Characterization of biodiesel and soot contamination on four-ball wear mechanisms using electron microscopy and confocal laser scanning microscopy
    Oungpakornkaew, Pitchaporn
    Karin, Preechar
    Tongsri, Ruangdaj
    Hanamura, Katsunori
    WEAR, 2020, 458