A novel low-profile external skeletal fixator for type IIIB open tibial fractures: A biomechanical and clinical pilot study

被引:1
|
作者
Tarng, Yih-Wen [1 ,2 ]
Lin, Kai-Cheng [1 ]
Lin, Kun-Jhih [3 ,4 ]
Yang, Yi-Ping [5 ]
Chien, Yeuh [5 ]
Wei, Hung-Wen [3 ,4 ]
机构
[1] Kaohsiung Vet Gen Hosp, Dept Orthopaed, 386 Da Chung 1st Rd, Kaohsiung 813, Taiwan
[2] Natl Def Med Ctr, Dept Orthopaed, Taipei, Taiwan
[3] Chung Yuan Christian Univ, Dept Elect Engn, Taoyuan, Taiwan
[4] Chung Yuan Christian Univ, Technol Translat Ctr Med Device, Taoyuan, Taiwan
[5] Taipei Vet Gen Hosp, Dept Med Res, Taipei, Taiwan
关键词
Bone union; Gustilo open type IIIb; Low-profile external skeletal fixator; Tibial fractures; LOCKING COMPRESSION PLATE; EXPERIENCE; MANAGEMENT; TEMPORARY; INJURIES; CLOSURE;
D O I
10.1097/JCMA.0000000000000506
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Although external fixator is standard for managing staged treatment of open tibial fracture, the main disadvantage of this device is too bulky to be tolerated by most patients for longtime use. The purposes of this pilot study were to compare the biomechanical properties of a novel low-profile external fixator (LP-ESF) with a traditional ESF and also to evaluate its performance in patients with Gustilo type IIIb tibial open fractures. Methods: A prospective clinical pilot study started from January 2015 to December 2017, and 18 patients with Gustilo type IIIb open tibial fractures underwent the fixation with a novel LP-ESF system. The biomechanical properties of the LP-ESF were compared with the Synthes External Fixation System according to the standard ASTM F1541-02. These patients were divided into two groups according to the size of bony defect. The postoperative clinical outcomes were subsequently collected. Results: The biomechanical properties of the LP-ESF were comparable with those of Synthes External Fixation System and had an improved the axial/torsional stiffness and ultimate strength. In the clinical study, all patients with LP-ESF had fracture union. The duration of application of LP-ESF was 3.5 to 18 months until fracture union. In 10 of 18 patients, their fractures were immobilized with the LP-ESF until bone union, and no pin tract infection and no chronic osteomyelitis were recorded. The 36-Item Short Form Health Survey life quality and health survey were good to excellent in these patients. Notably, the LP-ESF allowed a patient with severe bone and soft-tissue defects to preserve the leg and joints function. Conclusion: In this study, we found that the novel LP-ESFs had improved clinical outcomes. The long-term LP-ESF application seems to be tolerable in our patients. This novel approach permits better controls in deep infection and faster healing of fractures, and thus may provide a viable alternative treatment for Gustilo type IIIb open tibial fractures.
引用
收藏
页码:528 / 535
页数:8
相关论文
共 48 条
  • [31] Biomechanical Evaluation Method to Optimize External Fixator Configuration in Long Bone Fractures-Conceptual Model and Experimental Validation Using Pilot Study
    Sellahewa, Thiran
    Weerasinghe, Charitha
    Silva, Pujitha
    APPLIED SCIENCES-BASEL, 2021, 11 (18):
  • [32] Primary stability of nailing versus low-profile dual plating of mid-clavicular fractures– a biomechanical cadaveric study
    Fabian Pretz
    Ivan Zderic
    Frank J. P. Beeres
    Björn-Christian Link
    Reto Babst
    Yannic Lecoultre
    Boyko Gueorguiev
    Peter Varga
    Torsten Pastor
    Bryan J. M. van de Wall
    European Journal of Trauma and Emergency Surgery, 2025, 51 (1)
  • [33] Outcomes of anterolateral thigh-free flaps and conversion from external to internal fixation with bone grafting in gustilo type IIIB open tibial fractures
    Lee, Jae Hoon
    Chung, Duke Whan
    Han, Chung Soo
    MICROSURGERY, 2012, 32 (06) : 431 - 437
  • [34] The use of circular and hybrid external skeletal fixation systems to repair open tibial fractures in large ruminants: a report of six clinical cases
    Mudasir Ahmad Shah
    Rohit Kumar
    Prakash Kinjavdekar
    H. P. Amarpal
    Mohammad Aithal
    Asif Arif Basha
    Veterinary Research Communications, 2022, 46 : 563 - 575
  • [35] The use of circular and hybrid external skeletal fixation systems to repair open tibial fractures in large ruminants: a report of six clinical cases
    Shah, Mudasir Ahmad
    Kumar, Rohit
    Kinjavdekar, Prakash
    Amarpal
    Aithal, H. P.
    Arif Basha, Mohammad
    Majid, Asif
    VETERINARY RESEARCH COMMUNICATIONS, 2022, 46 (02) : 563 - 575
  • [36] Treatment of type II, IIIA, and IIIB open fractures of the tibial shaft: A prospective comparison of unreamed interlocking intramedullary nails and half-pin external fixators
    Henley, MB
    Chapman, JR
    Agel, J
    Harvey, EJ
    Whorton, AM
    Swiontkowski, MF
    JOURNAL OF ORTHOPAEDIC TRAUMA, 1998, 12 (01) : 1 - 7
  • [37] New Generation Superior Single Plating versus Low-Profile Dual Mini-Fragment Plating of Diaphyseal Clavicle Fractures - A Biomechanical Study
    Pastor, T.
    Pastor, T.
    Zderic, I.
    Berk, T.
    Souleiman, F.
    Vogelin, E.
    Beeres, F.
    Gueorguiev, B.
    BRITISH JOURNAL OF SURGERY, 2024, 111
  • [38] New Generation Superior Single Plating versus Low-Profile Dual Mini-Fragment Plating of Diaphyseal Clavicle Fractures - A Biomechanical Study
    Pastor, T.
    Pastor, T.
    Zderic, I
    Berk, T.
    Souleiman, F.
    Vogelin, E.
    Beeres, F.
    Gueorguiev, B.
    BRITISH JOURNAL OF SURGERY, 2024, 111
  • [39] Results of Distal Tibia Extra-Articular Type I & Type II Open Fractures Treated with Primary Ilizarov External Fixator - A Prospective Observational Study
    Barua, Debanga Sarma
    Bora, Monoranjan How
    Das, Manas Jyoti
    Bansal, Sidhartha
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2019, 8 (37): : 2856 - 2860
  • [40] New generation of superior single plating vs. low-profile dual minifragment plating in diaphyseal clavicle fractures: a biomechanical comparative study
    Pastor, Tatjana
    Zderic, Ivan
    Berk, Till
    Souleiman, Firas
    Vogelin, Esther
    Beeres, Frank J. P.
    Gueorguiev, Boyko
    Pastor, Torsten
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2024, 33 (02) : 409 - 416