Effect of contrast-enhanced CT scans on heterogeneity corrected dose computations in the lung

被引:0
|
作者
Burridge, Nichola A.
Rowbottom, Carl G.
Burt, Paul A.
机构
[1] Christie Hosp NHS Trust, N Western Med Phys, Manchester M20 4BX, Lancs, England
[2] Christie Hosp NHS Trust, Dept Clin Oncol, Manchester M20 4BX, Lancs, England
来源
关键词
radiotherapy; dose calculations; contrast; enhanced CT;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to investigate and, if possible, compensate for the effect of intravenous contrast-enhanced CT scans on the treatment planning dose distributions for lung patients. The contrast and noncontrast CT scans of 3 patients were registered, and the effect of contrast on the Hounsfield units (HU) was assessed. The effect of contrast was then simulated in the CT scans of 18 patients receiving radiotherapy of the lung by modification of the CT numbers for relevant sections of noncontrast-enhanced CT scans. All treatment planning was performed on the Pinnacle(3) planning system. The dose distributions computed from simulated contrast CT scans were compared to the original dose distributions by comparison of the monitor units (MUs) for each beam in the treatment plan required to deliver the prescribed dose to the isocenter as well as a comparison of the total MUs for each patient, a percentage change in required MUs being equivalent to a percentage change in the dose. A correction strategy to enable the use of contrast-enhanced CT scans in treatment planning was developed, and the feasibility of applying the strategy was investigated by calculating dose distributions for both the original and simulated contrast CT scans. A mean increase in the overall patient MUs of 1.0 +/- 0.8% was found, with a maximum increase of 3.3% when contrast was simulated on the original CT scans. The simulated contrast scans confirmed that the use of contrast-enhanced CT scans for routine treatment planning would result in a systematic change in the dose delivered to the isocenter. The devised correction strategy had no clinically relevant effect on the dose distribution for the original CT scans. The application of the correction strategy to the simulated contrast CT scans led to a reduction of the mean difference in the overall MUs to 0.1 +/- 0.2% compared to the original scan, demonstrating that the effect of contrast was eliminated with the correction strategy. This work has highlighted the problems associated with using contrast-enhanced CT scans in heterogeneity corrected dose computation. Contrast visible in the CT scan is transient and should not be accounted for in the treatment plan. A correction strategy has been developed that minimizes the effect of intravenous contrast while having no clinical effect on noncontrast CT scans. The correction strategy allows the use of contrast without detriment to the treatment plan.
引用
收藏
页码:1 / 12
页数:12
相关论文
共 50 条
  • [41] When to Order Contrast-Enhanced CT
    Rawson, James V.
    Pelletier, Allen L.
    AMERICAN FAMILY PHYSICIAN, 2013, 88 (05) : 312 - 316
  • [42] HIVES DURING CONTRAST-ENHANCED CT
    BUSH, WH
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (06) : 1543 - 1544
  • [43] PET/CT in malignant melanoma: contrast-enhanced CT versus plain low-dose CT
    Pfluger, T.
    Schneider, V.
    LaFougere, C.
    Coppenrath, E.
    Berking, C.
    Tiling, R.
    Bartenstein, P.
    Weiss, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S199 - S199
  • [44] PET/CT in malignant melanoma: contrast-enhanced CT versus plain low-dose CT
    Thomas Pfluger
    Henriette Ingrid Melzer
    Vera Schneider
    Christian La Fougere
    Eva Coppenrath
    Carola Berking
    Peter Bartenstein
    Mayo Weiss
    European Journal of Nuclear Medicine and Molecular Imaging, 2011, 38 : 822 - 831
  • [45] PET/CT in malignant melanoma: contrast-enhanced CT versus plain low-dose CT
    Pfluger, Thomas
    Melzer, Henriette Ingrid
    Schneider, Vera
    La Fougere, Christian
    Coppenrath, Eva
    Berking, Carola
    Bartenstein, Peter
    Weiss, Mayo
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (05) : 822 - 831
  • [46] Patient Dose Reduction at PET/CT: Use Contrast-Enhanced CT as Part of the PET/CT Examination
    Rodgers, B.
    Duddalwar, V
    Lee, K.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05)
  • [47] Dose Contrast-Enhanced CT Provide More Information for Liber in Radiomics Study
    Hu, P.
    Wang, J.
    Shen, L.
    Luo, R.
    Gan, J.
    Hu, W.
    Zhang, Z.
    MEDICAL PHYSICS, 2017, 44 (06) : 3212 - 3212
  • [48] Frequency, outcome, and risk factors of contrast media extravasation in 142,651 intravenous contrast-enhanced CT scans
    Eui Jin Hwang
    Cheong-Il Shin
    Young Hun Choi
    Chang Min Park
    European Radiology, 2018, 28 : 5368 - 5375
  • [49] Frequency, outcome, and risk factors of contrast media extravasation in 142,651 intravenous contrast-enhanced CT scans
    Hwang, Eui Jin
    Shin, Cheong-Il
    Choi, Young Hun
    Park, Chang Min
    EUROPEAN RADIOLOGY, 2018, 28 (12) : 5368 - 5375
  • [50] Role of contrast-enhanced dynamic CT for evaluating tumor angiogenesis in lung cancer
    Tateishi, U
    Kusumoto, M
    Tsuchiya, R
    Moriyama, N
    RADIOLOGY, 2001, 221 : 211 - 211