Total hip replacements with metal-on-polyethylene bearings

被引:0
|
作者
Kovac, Simon [2 ]
Trebse, Rihard [2 ]
Berce, Ales [2 ]
Milosev, Ingrid [1 ,2 ]
机构
[1] Jozef Stefan Inst, Ljubljana 1000, Slovenia
[2] Ortopedska Bolnisnica Valdoltra, Ankaran 6280, Slovenia
关键词
polyethylene; UHMWPE; orthopaedics; wear; wear particles; MOLECULAR-WEIGHT POLYETHYLENE; UHMWPE ACETABULAR CUPS; TOTAL JOINT REPLACEMENTS; KAPPA-B LIGAND; WEAR DEBRIS; GAMMA-RADIATION; FEMORAL-HEAD; FOLLOW-UP; PERIPROSTHETIC OSTEOLYSIS; OSTEOCLAST DIFFERENTIATION;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Polyethylene has been used as a bearing material for more than fifty years. It represents a golden standard in orthopaedics. Today the most important processes for manufacture of polyethylene are compression moulding and ram extrusion. As sterilization methods, irradiation with gamma rays in vacuum or inert gas and sterilization in plasma or ethylene oxide are used. Characteristics: Wear of polyethylene and consequent formation of wear particles are the key factor in the mechanism of aseptic loosening of total hip replacements. Pathophysiology of loosening is a complex process. Osteoclasts and their precursors have a crucial role in bone resorption. The differentiation of these multinucleated cells and their activation is regulated RANK/RANKL/OPG regulatory axis. Clinical results: Long-term results of the use of bearings with a metal femoral head and a polyethylene acetabular cup are good although dependent on the size of the used femoral head and the quality of polyethylene. However, these results are inferior to those obtained with a ceramic femoral head and a polyethylene cup, as well as those obtained with cross-linked polyethylene and ceramic-on-ceramic bearings. Conclusions: In-vitro simulation cannot fully predict the effect of various factors which in vivo affect the physical and chemical properties of polyethylene. The development of polethylene has thus not been completed yet. Currently, the research is targeted at highly cross-linked polyethylene and polyethylene enriched with alpha-tocopherol.
引用
收藏
页码:9 / 20
页数:12
相关论文
共 50 条
  • [21] Metal-on-polyethylene is not an option after the fracture of a ceramic component of a total hip arthroplasty
    Fernandez-Valencia, Jenaro A.
    [J]. HIP INTERNATIONAL, 2016, 26 (06) : E56 - E56
  • [22] Mid-to-long term follow-up of Transcend metal-on-metal versus Interseal metal-on-polyethylene bearings in total hip arthroplasty
    Yoon, James P.
    Le Duff, Michel J.
    Takamura, Karren M.
    Hodge, Stephen
    Amstutz, Harlan C.
    [J]. HIP INTERNATIONAL, 2011, 21 (05) : 571 - 576
  • [23] Comparison of Complications Following Revision of Metal-on-Metal Versus Metal-on-Polyethylene Total Hip Arthroplasty
    Nishio, Shoji
    Fukunishi, Shigeo
    Yoshiya, Shinichi
    Sing, David C.
    Hansen, Erik N.
    Vail, Thomas P.
    [J]. ORTHOPEDICS, 2017, 40 (01) : E164 - E169
  • [24] Blood metal ions after hybrid metal-on-polyethylene Exeter−Trident total hip replacement
    Singh R.
    Manoharan G.
    Craig P.
    Collier S.
    Shaylor P.
    Sinha A.
    [J]. Journal of Orthopaedics and Traumatology, 2016, 17 (2) : 149 - 153
  • [25] Clinically insignificant trunnionosis in large- diameter metal-on-polyethylene total hip arthroplasty
    Hothi, H. S.
    Kendoff, D.
    Lausmann, C.
    Henckel, J.
    Gehrke, T.
    Skinner, J.
    Hart, A.
    [J]. BONE & JOINT RESEARCH, 2017, 6 (01): : 52 - 56
  • [26] Edge Loading Has a Paradoxical Effect on Wear in Metal-on-Polyethylene Total Hip Arthroplasties
    Harris, William H.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (11) : 3077 - 3082
  • [27] Higher Prevalence of Mixed or Solid Pseudotumors in Metal-on-Polyethylene Total Hip Arthroplasty Compared With Metal-on-Metal Total Hip Arthroplasty and Resurfacing Hip Arthroplasty
    Hjorth, Mette Holm
    Mechlenburg, Inger
    Soballe, Kjeld
    Roemer, Lone
    Jakobsen, Stig Storgaard
    Stilling, Maiken
    [J]. JOURNAL OF ARTHROPLASTY, 2018, 33 (07): : 2279 - 2286
  • [28] Systemic lupus erythematosus induced by adjuvants after metal-on-polyethylene total hip arthroplasty
    Wang Chang-Chao
    Huang Yan
    Huang Ya-Dong
    [J]. 中华医学杂志(英文版), 2020, 133 (12) : 1499 - 1500
  • [29] Systemic lupus erythematosus induced by adjuvants after metal-on-polyethylene total hip arthroplasty
    Wang, Chang-Chao
    Huang, Yan
    Huang, Ya-Dong
    [J]. CHINESE MEDICAL JOURNAL, 2020, 133 (12) : 1499 - 1500
  • [30] Chromium nitride coating for large diameter metal-on-polyethylene hip bearings under extreme adverse hip simulator conditions
    de Villiers, Danielle
    Traynor, Alison
    Collins, Simon N.
    Banfield, Sarah
    Housden, Jonathan
    Shelton, Julia C.
    [J]. WEAR, 2015, 328 : 363 - 368