Grey-scale contrast enhancement in rabbit liver with SonoVue™ at different doses

被引:14
|
作者
Li, J [1 ]
Dong, BW
Yu, XL
Wang, XH
Li, CF
机构
[1] Shandong Univ, Qilu Hosp, Dept Ultrasound, Jinan 250012, Peoples R China
[2] Gen PLA Hosp, Dept Ultrasound, Beijing, Peoples R China
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2005年 / 31卷 / 02期
关键词
ultrasound; contrast agents; harmonic imaging; liver; in vivo; dose;
D O I
10.1016/j.ultrasmedbio.2004.10.009
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
To evaluate the dose of ultrasound (US) contrast agent (UCA) in relation to the contrast-enhancement effect, an in vivo model of perfusion was studied using SonoVue(TM), a second-generation UCA, and low mechanical index (MI) grey-scale harmonic imaging. SonoVue(TM), at eight different doses (0.02, 0.04, 0.06, 0.08, 0.10, 0.12, 0.14 and 0.16 mL/kg BW), was applied in five normal rabbits. Flow-related parameters obtained from time-intensity curves were calculated and plotted over the contrast agent doses, and nonlinear curve fitting was performed. Results showed that, along with an increase of the administrated contrast agent dose, the enhancement duration (ED) and the area under the curve (AUC) increased logarithmically, and the time to enhancement (ET) decreased logarithmically. There was a progressive increase of the peak signal intensity (PSI) following an increase of SonoVue(TM) dose only in the dose range of 0.02 up to 0.10 mL/kg body weight (BW) in the portal vein and in the dose range of 0.02 up to 0.12 mL/kg BW in the liver parenchyma. Moreover, a good correlation was observed between the parameters obtained from liver parenchyma and those obtained from the portal vein. The results indicated that SonoVue(TM) in conjunction with continuous harmonic low-MI grey-scale imaging has the capability of flow quantification on both vessels and parenchyma. The parameters of time-intensity curve were influenced intensely by different contrast agent doses. (E-mail: jieli301@hotmaill.com) (C) 2005 World Federation for Ultrasound in Medicine Biology.
引用
收藏
页码:185 / 190
页数:6
相关论文
共 50 条
  • [21] Comparison of contrast-enhanced ultrasonography with grey-scale ultrasonography and contrast-enhanced computed tomography in diagnosing focal fatty liver infiltrations and focal fatty sparing
    Janica, J.
    Ustymowicz, A.
    Lukasiewicz, A.
    Panasiuk, A.
    Niemcunowicz-Janica, A.
    Turecka-Kulesza, E.
    Lebkowska, U.
    ADVANCES IN MEDICAL SCIENCES, 2013, 58 (02): : 408 - 418
  • [22] Detection of vascularity in wrist tenosynovitis: power doppler ultrasound compared with contrast-enhanced grey-scale ultrasound
    Andrea S Klauser
    Magdalena Franz
    Rohit Arora
    Gudrun M Feuchtner
    Johann Gruber
    Michael Schirmer
    Werner R Jaschke
    Markus F Gabl
    Arthritis Research & Therapy, 12
  • [23] Detection of vascularity in wrist tenosynovitis: power doppler ultrasound compared with contrast-enhanced grey-scale ultrasound
    Klauser, Andrea S.
    Franz, Magdalena
    Arora, Rohit
    Feuchtner, Gudrun M.
    Gruber, Johann
    Schirmer, Michael
    Jaschke, Werner R.
    Gabl, Markus F.
    ARTHRITIS RESEARCH & THERAPY, 2010, 12 (06)
  • [24] Quantification of flow rates using harmonic grey-scale imaging and an ultrasound contrast agent:: an in vitro and in vivo study
    Claassen, L
    Seidel, G
    Algermissen, C
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (01): : 83 - 88
  • [25] CORRELATION OF CT CONTRAST ENHANCEMENT WITH IODINE CONCENTRATION IN RABBIT LIVER
    VIOLANTE, MR
    DEAN, PB
    BURGENER, FA
    FISCHER, HW
    INVESTIGATIVE RADIOLOGY, 1978, 13 (05) : 394 - 394
  • [26] PRELIMINARY RESULTS OF GREY-SCALE ULTRASONOGRAPHY IN DETECTION OF VINYL-CHLORIDE RELATED LIVER AND SPLEEN DISEASE
    TAYLOR, KJW
    BARRETT, JJ
    WILLIAMS, DMJ
    SMITH, PM
    DUCK, BW
    PROCEEDINGS OF THE ROYAL SOCIETY OF MEDICINE-LONDON, 1976, 69 (04): : 292 - 295
  • [27] ACCURACY OF GREY-SCALE ULTRASONOGRAPHY OF LIVER AND SPLEEN IN HODGKINS-DISEASE AND OTHER LYMPHOMAS COMPARED WITH ISOTOPE SCANS
    GLEES, JP
    TAYLOR, KJW
    GAZET, JC
    PECKHAM, MJ
    MCCREADY, VR
    CLINICAL RADIOLOGY, 1977, 28 (02) : 233 - 238
  • [28] Sonographic imaging of extra-testicular focal lesions: comparison of grey-scale, colour Doppler and contrast-enhanced ultrasound
    Rafailidis, Vasileios
    Robbie, Hasti
    Konstantatou, Eleni
    Huang, Dean Y.
    Deganello, Annamaria
    Sellars, Maria E.
    Cantisani, Vito
    Isidori, Andrea M.
    Sidhu, Paul S.
    ULTRASOUND, 2016, 24 (01) : 23 - 33
  • [29] Liver stiffness measurements with supersonic shear wave elastography in the diagnosis of biliary atresia: a comparative study with grey-scale US
    Lu-yao Zhou
    Hong Jiang
    Quan-yuan Shan
    Dong Chen
    Xiao-na Lin
    Bao-xian Liu
    Xiao-yan Xie
    European Radiology, 2017, 27 : 3474 - 3484
  • [30] Liver stiffness measurements with supersonic shear wave elastography in the diagnosis of biliary atresia: a comparative study with grey-scale US
    Zhou, Lu-yao
    Jiang, Hong
    Shan, Quan-yuan
    Chen, Dong
    Lin, Xiao-na
    Liu, Bao-xian
    Xie, Xiao-yan
    EUROPEAN RADIOLOGY, 2017, 27 (08) : 3474 - 3484