Calibration Transfer from Dispersive Instruments to Handheld Spectrometers

被引:44
|
作者
Pierna, Juan Antonio Fernandez [1 ]
Vermeulen, Philippe [1 ]
Lecler, Bernard [1 ]
Baeten, Vincent [1 ]
Dardenne, Pierre [1 ]
机构
[1] CRA W, Valorisat Agr Prod Dept, Food & Qual Unit U15, B-5030 Gembloux, Belgium
关键词
Near-infrared spectroscopy; NIR calibration; Transfer; Micro-electro mechanical systems; MEMS; STANDARDIZATION;
D O I
10.1366/000370210791414353
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Foss NIRSystem 6500 is one of the most commonly used laboratory instruments in agriculture and in particular in feed. New technological developments include micro-electro mechanical system (MEMS) technology, used in miniature handheld instruments such as the Polychromix Phazir spectrometer that are increasingly required for on-site analysis. The objective of this study was to assess the potential of a calibration transfer from the Foss NIRSystem 6500 to the Polychromix Phazir. The results show that good calibration models were obtained for various feed properties (fat, fiber, protein, and starch) developed on a Foss NIRSystem 6500, based on a spectral database of 9164 samples transferred to a Polychromix Phazir handheld spectrometer.
引用
收藏
页码:644 / 648
页数:5
相关论文
共 50 条
  • [31] Multi-way based calibration transfer between two Raman spectrometers
    Kompany-Zareh, Mohsen
    van den Berg, Frans
    ANALYST, 2010, 135 (06) : 1382 - 1388
  • [32] Calibration transfer of near infrared spectrometers for the assessment of plasma ethanol precipitation process
    Sun, Zhongyu
    Wang, Jiayue
    Nie, Lei
    Li, Lian
    Cao, Dawei
    Fan, Jiajin
    Wang, Haiyan
    Liu, Ruichen
    Zhang, Yinran
    Zang, Hengchang
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2018, 181 : 64 - 71
  • [33] CALIBRATION OF GRAZING-INCIDENCE SPECTROMETERS USING CHARGE-TRANSFER EXCITATION
    ISLER, RC
    LANGLEY, RA
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1985, 56 (05): : 868 - 868
  • [34] Calibration transfer between low-field NMR instruments
    Galvan, Diego
    Danieli, Ernesto
    Borsato, Dionisio
    Killner, Mario
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 258
  • [35] Improved transfer standard sources for calibration of Earth Observation instruments
    Fox, NP
    Harrison, NJ
    Hunt, TM
    Pollard, DF
    Windsor, SA
    Woolliams, ER
    EARTH OBSERVING SYSTEMS VI, 2002, 4483 : 176 - 184
  • [36] Calibration of spectra from dispersive XAS beamlines
    Ruffoni, M. P.
    Pettifer, R. F.
    JOURNAL OF SYNCHROTRON RADIATION, 2006, 13 : 489 - 493
  • [37] CALIBRATION OF GAMMA-SPECTROMETERS
    LEGRAND, J
    NUCLEAR INSTRUMENTS & METHODS, 1973, 112 (1-2): : 229 - 238
  • [38] CALIBRATION PROCEDURES FOR PHOTOELECTRON SPECTROMETERS
    POOLE, RT
    LECKEY, RCG
    JENKIN, JG
    LIESEGANG, J
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1973, 6 (03): : 201 - 203
  • [39] WAVELENGTHS FOR CALIBRATION OF PRISM SPECTROMETERS
    PLYER, EK
    PETERS, CW
    JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS, 1950, 45 (06): : 462 - 468
  • [40] CALIBRATION AND MONITORING OF SPECTROMETERS AND SPECTROPHOTOMETERS
    FRINGS, CS
    BROUSSARD, LA
    CLINICAL CHEMISTRY, 1979, 25 (06) : 1013 - 1017