IMPROVING DISPLACEMENT SIGNAL-TO-NOISE RATIO FOR LOW-SIGNAL RADIATION FORCE ELASTICITY IMAGING USING BAYESIAN TECHNIQUES

被引:13
|
作者
Dumont, Douglas M. [1 ]
Walsh, Kristy M. [1 ]
Byram, Brett C. [1 ]
机构
[1] Vanderbilt Univ, Dept Biomed Engn, Nashville, TN 37235 USA
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2016年 / 42卷 / 08期
关键词
Displacement estimation; Elasticity imaging; Shear wave; Bayes; Medical imaging; Elastography; Ultrasound; SHEAR-WAVE ELASTOGRAPHY; IN-VIVO; ULTRASOUND ELASTOGRAPHY; PHYSIOLOGICAL MOTION; B-MODE; TRACKING; STIFFNESS; LIVER; FEASIBILITY; FIBROSIS;
D O I
10.1016/j.ultrasmedbio.2016.03.004
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Radiation force-based elasticity imaging is currently being investigated as a possible diagnostic modality for a number of clinical tasks, including liver fibrosis staging and the characterization of cardiovascular tissue. In this study, we evaluate the relationship between peak displacement magnitude and image quality and propose using a Bayesian estimator to overcome the challenge of obtaining viable data in low displacement signal environments. Displacement data quality were quantified for two common radiation force-based applications, acoustic radiation force impulse imaging, which measures the displacement within the region of excitation, and shear wave elasticity imaging, which measures displacements outside the region of excitation. Performance as a function of peak displacement magnitude for acoustic radiation force impulse imaging was assessed in simulations and lesion phantoms by quantifying signal-to-noise ratio (SNR) and contrast-to-noise ratio for varying peak displacement magnitudes. Overall performance for shear wave elasticity imaging was assessed in ex vivo chicken breast samples by measuring the displacement SNR as a function of distance from the excitation source. The results show that for any given displacement magnitude level, the Bayesian estimator can increase the SNR by approximately 9 dB over normalized cross-correlation and the contrast-to-noise ratio by a factor of two. We conclude from the results that a Bayesian estimator may be useful for increasing data quality in SNR-limited imaging environments. (E-mail: brett.c.byram@vanderbilt.edu) (C) 2016 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1986 / 1997
页数:12
相关论文
共 50 条
  • [31] Alignment mark optimization for improving signal-to-noise ratio of wafer alignment signal
    Du, Juyou
    Dai, Fengzhao
    Wang, Xiangzhao
    [J]. APPLIED OPTICS, 2019, 58 (01) : 9 - 14
  • [32] Frequency Hopping Signal Detection in Low Signal-to-Noise Ratio Regimes
    Hasan, Md. Zoheb
    Couto, David J.
    Abdel-Malek, Mai A.
    Reed, Jeffrey H.
    [J]. 2023 IEEE 34TH ANNUAL INTERNATIONAL SYMPOSIUM ON PERSONAL, INDOOR AND MOBILE RADIO COMMUNICATIONS, PIMRC, 2023,
  • [33] A radar echo signal detection algorithm in low signal-to-noise ratio
    Li, Xiangju
    [J]. PROCEEDINGS OF THE 2016 3RD INTERNATIONAL CONFERENCE ON MATERIALS ENGINEERING, MANUFACTURING TECHNOLOGY AND CONTROL, 2016, 67 : 349 - 353
  • [34] Measurement of Signal-to-Noise Ratio and Signal-to-Noise and Distortion Ratio Using Histogram Test in Time Domain Analysis
    Jain, Manish
    Sharma, Prakash Chandra
    Tiwari, Pradeep Kumar
    Gupta, Rohit Kumar
    [J]. SMART SYSTEMS: INNOVATIONS IN COMPUTING (SSIC 2021), 2022, 235 : 403 - 410
  • [35] Maximisation of signal-to-noise ratio in infrared radiation receivers
    Bielecki, Z
    [J]. OPTO-ELECTRONICS REVIEW, 2002, 10 (03) : 209 - 216
  • [36] Signal-to-noise ratio evaluation radiography with synchrotron radiation
    Fabbri, S
    Taibi, A
    Longo, R
    Marziani, M
    Olivo, A
    Pani, S
    Tuffanelli, A
    Gambaccini, M
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (22): : 4093 - 4105
  • [37] Reliability of predicting signal-to-noise ratio using NECR in PET imaging
    Chang, Tingting
    Clark, John
    Mawlawi, Osama
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [38] Signal-to-noise ratio and errors in measuring the signal parameters for heterodyne detection of radiation
    Gryaznov, N.A.
    [J]. Journal of Optical Technology (A Translation of Opticheskii Zhurnal), 1998, 65 (04): : 284 - 287
  • [39] Imaging Signal-to-Noise Ratio of Synthetic Aperture Ladar
    Liu, Liren
    [J]. UNCONVENTIONAL IMAGING AND WAVEFRONT SENSING 2015, 2015, 9617
  • [40] Signal-to-noise ratio limitations for intensity correlation imaging
    Fried, David L.
    Riker, Jim
    Agrawal, Brij
    [J]. Journal of the Optical Society of America A: Optics and Image Science, and Vision, 2014, 31 (07): : 1536 - 1546