Visual acuity and endothelial cell density with respect to the graft thickness in Descemet's stripping automated endothelial keratoplasty: one year results

被引:21
|
作者
Acar, Banu Torun [1 ]
Akdemir, Mehmet Orcun [2 ]
Acar, Sirphi [1 ]
机构
[1] Haydarpasa Numune Res & Educ Hosp, Ophthalmol Clin, TR-34668 Istanbul, Turkey
[2] Bulent Ecevit Univ, Sch Med, Dept Ophthalmol, TR-67600 Zonguldak, Turkey
关键词
Descemet's stripping endothelial keratoplasty; graft thickness; visual acuity; corneal endothelial cell density; ANTERIOR LAMELLAR KERATOPLASTY; PENETRATING KERATOPLASTY; LENTICULE THICKNESS;
D O I
10.3980/j.issn.2222-3959.2014.06.11
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
AIM: To evaluate the visual acuity and endothelial cell density according to the thickness in Descemet's stripping automated endothelial keratoplasty (DSAEK) one year after surgery. METHODS: DSAEK patients' data were reviewed. Thirty seven eyes of 37 patients who underwent DSAEK for pseudophakic bullous keratopathy (PBK) were included in this study. Graft thickness was measured with optical coherence tomography (OCT) 12mo after DSAEK. Eyes were divided into 3 groups based on the graft thickness: thick (>200 mu m), medium-thick (150-200 mu m) and thin (<150 mu m). Best corrected visual acuity (BCVA), endothelial cells density (ECD) and complications were assessed and comparisons were done between groups. RESULTS: Median thickness of postoperative grafts was 188 (range 73-317 mu m). There was no significant difference in age, sex, preoperative BCVA, or follow-up period between DSAEK groups. At postoperative 12mo, mean BCVA was 0.28 +/- 0.10 in thick graft group, 0.52 +/- 0.08 in medium-thick graft group, and 0.721 +/- 0.06 in thin graft group. Thin grafts showed better postoperative BCVA as compared with the medium -thick and thick grafts (P=0.001). Thick graft group had 1637.44 +/- 88.19 -mm(2), medium thick graft had 1764.50 +/- 34.28-mm(2) and thin graft group had 1845.30 +/- 65.62 -mm(2). Thin graft group had better ECD at 12mo after surgery (P=0.001). CONCLUSION: Thin grafts after DSAEK ensure better visual rehabilitation. Eyes with thin grafts had significantly lesser loss of ECD compared to eyes with medium thick and thick grafts one year after surgery.
引用
收藏
页码:974 / 979
页数:6
相关论文
共 50 条
  • [21] Endothelial Cell Loss and Graft Survival after Descemet's Stripping Automated Endothelial Keratoplasty and Penetrating Keratoplasty
    Ang, Marcus
    Mehta, Jodhbir S.
    Lim, Fiona
    Bose, Saideep
    Htoon, Hla Myint
    Tan, Donald
    OPHTHALMOLOGY, 2012, 119 (11) : 2239 - 2244
  • [22] A Comparison of the Corneal Thickness Following Descemet's Stripping Automated Endothelial Keratoplasty and Descemet's Membrane Endothelial Keratoplasty
    Sunouchi, Chihiro
    Hayashi, Takahiko
    Shimizu, Toshiki
    Hara, Yusuke
    Kurita, Junki
    Kobashigawa, Hiroko
    Oyakawa, Itaru
    Ida, Yasutsugu
    Kobayashi, Akira
    Shoji, Jun
    Yamagami, Satoru
    CURRENT EYE RESEARCH, 2023, 48 (08) : 712 - 718
  • [23] Two year visual acuity and contrast sensitivity outcome following Descemet's Stripping Automated endothelial keratoplasty (DSAEK) and the correlation with preoperative donor graft thickness
    Lim, Fiona Pin Miao
    Ang, Marcus
    Htoon, Hla
    Tan, Donald
    Mehta, Jodhbir
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [24] Effect of the shape of the endothelial graft on the refractive results after Descemet's stripping with automated endothelial keratoplasty
    Esquenazi, Salomon
    Rand, William
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2009, 44 (05): : 557 - 561
  • [25] The Effect of Donor Graft Thickness in Descemet Stripping Automated Endothelial Keratoplasty Surgery
    Van Laere, Lily
    Cuttler, Nirupa
    Spigelman, Alan
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [26] Graft Rejection After Descemet's Stripping Automated Endothelial Keratoplasty Graft Survival and Endothelial Cell Loss
    Li, Jennifer Y.
    Terry, Mark A.
    Goshe, Jeffrey
    Shamie, Neda
    Davis-Boozer, David
    OPHTHALMOLOGY, 2012, 119 (01) : 90 - 94
  • [27] Postoperative Endothelial Cell Density Is Associated with Late Endothelial Graft Failure after Descemet Stripping Automated Endothelial Keratoplasty
    Patel, Sanjay, V
    Lass, Jonathan H.
    Benetz, Beth Ann
    Szczotka-Flynn, Loretta B.
    Cohen, Nathan J.
    Ayala, Allison R.
    Maguire, Maureen G.
    Drury, Donna C.
    Dunn, Steven P.
    Jeng, Bennie H.
    Jones, Marc F.
    Menegay, Harry J.
    Oliva, Matthew S.
    Rosenwasser, George O. D.
    Seedor, John A.
    Terry, Mark A.
    Verdier, David D.
    OPHTHALMOLOGY, 2019, 126 (08) : 1076 - 1083
  • [28] Descemet's Stripping Automated Endothelial Keratoplasty
    Bronner, Aaron
    OPTOMETRY AND VISION SCIENCE, 2008, 85 (09) : 808 - 813
  • [29] Descemet's Stripping Automated Endothelial Keratoplasty
    Chaurasia, Sunita
    Ramappa, Muralidhar
    Rao, Harsha Laxmana
    Bansal, Piyush
    OPHTHALMOLOGY, 2012, 119 (07) : 1498 - 1499
  • [30] Descemet Membrane Endothelial Keratoplasty as Treatment for Graft Failure After Descemet Stripping Automated Endothelial Keratoplasty
    Weller, Julia M.
    Tourtas, Theofilos
    Kruse, Friedrich E.
    Schloetzer-Schrehardt, Ursula
    Fuchsluger, Thomas
    Bachmann, Bjoern O.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2015, 159 (06) : 1050 - 1057