Methylene Blue Does Not Improve Vasoplegia After Left Ventricular Assist Device Implantation

被引:5
|
作者
Saha, Amit [1 ,2 ,3 ,4 ,5 ]
Jennings, Douglas L. [1 ,2 ,3 ,4 ,5 ]
Ning, Yuming [1 ,2 ,3 ,4 ,5 ]
Kurlansky, Paul [1 ,2 ,3 ,4 ,5 ]
Miltiades, Andrea N. [1 ,2 ,3 ,4 ,5 ]
Spellman, Jessica L. [1 ,2 ,3 ,4 ,5 ]
Sanchez, Joseph [1 ,2 ,3 ,4 ,5 ]
Yuzefpolskaya, Melana [1 ,2 ,3 ,4 ,5 ]
Colombo, Paolo C. [1 ,2 ,3 ,4 ,5 ]
Takayama, Hiroo [1 ,2 ,3 ,4 ,5 ]
Naka, Yoshifumi [1 ,2 ,3 ,4 ,5 ]
Takeda, Koji [1 ,2 ,3 ,4 ,5 ]
机构
[1] Columbia Univ, Irving Med Ctr, Dept Surg, Div Cardiac Thorac & Vasc Surg, 177 Ft Washington Ave, New York, NY 10032 USA
[2] Columbia Univ, Dept Pharm, Irving Med Ctr, New York, NY USA
[3] Columbia Univ, Dept Surg, Irving Med Ctr, New York, NY USA
[4] Columbia Univ, Dept Anesthesiol, Irving Med Ctr, Div Adult Cardiothorac Anesthesiol, New York, NY USA
[5] Columbia Univ, Dept Med, Irving Med Ctr, Div Cardiol, New York, NY USA
来源
ANNALS OF THORACIC SURGERY | 2021年 / 111卷 / 03期
关键词
D O I
10.1016/j.athoracsur.2020.05.172
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Vasoplegia is a frequent complication of left ventricular assist device (LVAD) implantation. We investigated the effectiveness of methylene blue (MB) for vasoplegia in LVAD recipients. Methods. Twenty-seven patients received MB for vasoplegia after LVAD implantation and met study criteria between March 2015 and May 2018. Propensity score inverse probability weighting identified 41 controls who did not receive MB for post-LVAD vasoplegia. Clinical outcomes were compared between control and MB groups and between patients who received doses during (n = 15) and after surgery (n = 12). Hemodynamics and vasopressor requirements were analyzed using analysis of covariance. Results. Median total MB dose was 1.9 mg/kg (interquartile range, 1.2-2.2 mg/kg). Methylene blue recipients experienced a transient initial decline in norepinephrine requirement from 141 ng/kg per min (95% confidence interval [CI], 81-201 ng/kg per min) to 117 ng/kg per min (95% CI, 58-176 ng/kg per min; P = .022) and a delayed decline in vasopressin from 4.8 U/h (95% CI, 3.8-5.8 U/h) to 4.0 U/h (95% CI, 2.8-5.1 U/h) (P = .004). In-hospital mortality, postoperative complications, and end-organ dysfunction did not differ from those of controls. There were no observed differences in mean arterial pressure, vasopressor requirements, or outcomes between patients who received doses during or after surgery. Weighted overall mortality in the entire study cohort was 8.8%. Conclusions. Although MB may affect vasopressor requirements, clinical outcomes in vasoplegia after LVAD implantation did not improve and were not affected by the timing of administration. (C) 2021 by The Society of Thoracic Surgeons
引用
收藏
页码:800 / 808
页数:9
相关论文
共 50 条
  • [31] Wound complications after left ventricular assist device implantation
    Tjan, TDT
    Asfour, B
    Hammel, D
    Schmidt, C
    Scheld, HH
    Schmid, C
    [J]. ANNALS OF THORACIC SURGERY, 2000, 70 (02): : 538 - 541
  • [32] Hospital readmissions after left ventricular assist device implantation
    Lesny, P.
    Luknar, M.
    Simovicova, V.
    Dankova, M.
    Goncalvesova, E.
    [J]. EUROPEAN JOURNAL OF HEART FAILURE, 2018, 20 : 91 - 91
  • [33] Changes in Spirometry After Left Ventricular Assist Device Implantation
    Mohamedali, Burhan
    Bhat, Geetha
    Yost, Gardner
    Tatooles, Antone
    [J]. ARTIFICIAL ORGANS, 2015, 39 (12) : 1046 - 1050
  • [34] Outcomes and Complications after Left Ventricular Assist Device Implantation
    Wasilewski, Grzegorz
    Wisniowska-Smialek, Sylwia
    Gorkiewicz-Kot, Izabela
    Milaniak, Irena
    Kaleta, Michal
    Hymczak, Hubert
    Tomsia, Paulina
    Wierzbicki, Karol
    [J]. TRANSPLANTATION PROCEEDINGS, 2024, 56 (04) : 864 - 867
  • [35] Hospital readmissions after left ventricular assist device implantation
    Heim, Christian
    Mekkhala, Nattipong
    Kondruweit, Markus
    Weyand, Michael
    Tandler, Rene
    [J]. TRANSPLANTATION, 2016, 100 (07) : S41 - S41
  • [36] Postoperative management after implantation of a left ventricular assist device
    Pilarczyk, K.
    Pizanis, N.
    Kamler, M.
    Jakob, H. G.
    Beyersdorf, F.
    Trummer, G.
    [J]. ZEITSCHRIFT FUR HERZ THORAX UND GEFASSCHIRURGIE, 2014, 28 (05): : 337 - 346
  • [37] Pulmonary embolism after implantation of the left ventricular assist device
    Xiong, Xinghui
    Zhou, Ruihao
    Deng, Lijing
    [J]. ASIAN JOURNAL OF SURGERY, 2024, 47 (09) : 4226 - 4228
  • [38] Body Mass Index Does Not Predict Mortality After Left Ventricular Assist Device Implantation
    Upala, Sikarin
    Sanguankeo, Anawin
    [J]. JOURNAL OF CARDIAC FAILURE, 2016, 22 (01) : 95 - 96
  • [39] Right ventricular failure after left ventricular assist device implantation:: The need for an implantable right ventricular assist device
    Furukawa, K
    Motomura, T
    Nosé, Y
    [J]. ARTIFICIAL ORGANS, 2005, 29 (05) : 369 - 377
  • [40] Prediction of right ventricular dysfunction after left ventricular assist device implantation
    Nakatani, S
    Thomas, JD
    Savage, RM
    Vargo, RL
    Smedira, NG
    McCarthy, PM
    [J]. CIRCULATION, 1996, 94 (09) : 216 - 221