A Beryllium Oxide (BeO) Fibre-Coupled Luminescence Dosimeter for High Dose Rate Brachytherapy

被引:0
|
作者
Santos, A. [1 ,2 ,3 ]
Mohammadi, M. [1 ]
Afshar, S. [2 ,3 ]
机构
[1] Royal Adelaide Hosp, Adelaide, SA, Australia
[2] Inst Photon & Adv Sensing, Adelaide, SA, Australia
[3] Sch Chem & Phys, Adelaide, SA, Australia
关键词
D O I
10.1118/1.4889694
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SU-C-16A-0
引用
收藏
页码:90 / 90
页数:1
相关论文
共 50 条
  • [1] Investigation of a fibre-coupled beryllium oxide (BeO) ceramic luminescence dosimetry system
    Santos, Alexandre M. Caraca
    Mohammadi, Mohammad
    Afshar, Shahraam V.
    [J]. RADIATION MEASUREMENTS, 2014, 70 : 52 - 58
  • [2] Characterisation of a real-time fibre-coupled beryllium oxide (BeO) luminescence dosimeter in X-ray beams
    Santos, Alexandre M. Caraca
    Mohammadi, Mohammad
    Asp, Johan
    Monro, Tanya M.
    Afshar, Shahraam, V
    [J]. RADIATION MEASUREMENTS, 2013, 53-54 : 1 - 7
  • [3] Energy dependency of a water-equivalent fibre-coupled beryllium oxide (BeO) dosimetry system
    Santos, Alexandre M. Caraca
    Mohammadi, Mohammad
    Afshar, Shahraam V.
    [J]. RADIATION MEASUREMENTS, 2015, 73 : 1 - 6
  • [4] Evaluation of a real-time optically stimulated luminescence beryllium oxide (BeO) fibre-coupled dosimetry system with a superficial 140 kVp X-ray beam
    Santos, Alexandre M. Caraca
    Gowda, Raghu
    Bezak, Eva
    Afshar, Shahraam, V
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 65 : 167 - 171
  • [5] Evaluation of a real-time BeO ceramic fiber-coupled luminescence dosimetry system for dose verification of high dose rate brachytherapy
    Santos, Alexandre M. Caraca
    Mohammadi, Mohammad
    Afshar, Shahraam, V
    [J]. MEDICAL PHYSICS, 2015, 42 (11) : 6349 - 6356
  • [6] A plastic scintillation dosimeter for high dose rate brachytherapy
    Lambert, J.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S32 - S32
  • [7] A plastic scintillation dosimeter for high dose rate brachytherapy
    Lambert, J.
    McKenzie, D. R.
    Law, S.
    Elsey, J.
    Suchowerska, N.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (21): : 5505 - 5516
  • [8] Beryllium oxide as optically stimulated luminescence dosimeter
    Sommer, M.
    Jahn, A.
    Henniger, J.
    [J]. RADIATION MEASUREMENTS, 2008, 43 (2-6) : 353 - 356
  • [9] Dose and dose rate measurements in proton beams using the luminescence of beryllium oxide
    Teichmann, T.
    Torres, M. J. Gonzalez
    van Goethem, M. J.
    van der Graaf, E. R.
    Henniger, J.
    Jahn, A.
    Kiewiet, H. H.
    Sommer, M.
    Ullrich, W.
    Weinhold, C.
    Kormoll, T.
    [J]. JOURNAL OF INSTRUMENTATION, 2018, 13
  • [10] Optimization of a multipoint plastic scintillator dosimeter for high dose rate brachytherapy
    Rosales, Haydee M. Linares
    Duguay-Drouin, Patricia
    Archambault, Louis
    Beddar, Sam
    Beaulieu, Luc
    [J]. MEDICAL PHYSICS, 2019, 46 (05) : 2412 - 2421