Frequency of diagnostic dilemmas in 131I whole body scanning

被引:0
|
作者
Leitha, T
Staudenherz, A
机构
[1] Danauspital Wien, Abt Diangost & Theapuet Nukl Med, Vienna, Austria
[2] Univ Vienna, Klin Nukl Med, Vienna, Austria
来源
NUKLEARMEDIZIN-NUCLEAR MEDICINE | 2003年 / 42卷 / 02期
关键词
I-131; whole-body scan; differentiated thyroid cancer;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aim: The specific excretion pathways of iodine may cause several diagnostic pitfalls. Information concerning their relative frequency and possible consequences in doily routine is scarce. Methods: A total of 500 I-131 whole-body scans from 300 consecutive patients with differentiated thyroid cancer of two centers were analyzed. The reports were validated with other diagnostic findings during follow-up for 12 to 85 months. 126 scans (25.2%) were performed at the time of discharge after high dose I-131 therapy (2960-11100 MBq). Residual activity was approximately 185 MBq 1311 at the time of imaging. 374 scans (74.8%) were performed in ombulator patients 48 h after oral administration of 74 MBq(131)I. All patients revealed TSH concentrations >35 muU/ml. Results: A computerized literature search revealed 74 entities that may cause a false-positive whole body scan, from which 12 were present in our cohort. The uptake patterns could be epitomized into nine clinical settings. Apart from the significantly higher frequency of cervical activity in residual thyroid tissue in patients after high dose therapy no statistically significant difference was found between high and low dose patients. The most frequent combination was stomach and colon activity, which was seen in 15.3% of all scans. Additional images or diagnostic procedures were necessary in 59.3%. Only one patient with a kidney metastasis was initially misinterpreted. The major clinical problems included: contamination, superimposed intestinal retention, hot nose, isolated peripheral metastasis, unexpected breast activity and kidney metastasis. Conclusion: I-131 whole-body scanning has to be performed with painstaking precision and full awareness of even the rarest pitfalls in order to remain a sensitive and specific technique for diagnosing metastases from differentiated thyroid carcinoma.
引用
收藏
页码:55 / 62
页数:8
相关论文
共 50 条
  • [31] "Picture-in-Picture" Artifact in Post-therapeutic 131I Whole-body Survey: Deceiving Spot View but Unraveling Whole-body Scanning
    Qutbi, Mohsen
    Ahmadi, Reyhane
    [J]. MOLECULAR IMAGING AND RADIONUCLIDE THERAPY, 2022, 31 (02) : 142 - 144
  • [32] The effect of 131I dosages and vitamin C to salivary glands on the post-therapeutic 131I whole-body scans in patients with DTC
    Li, Na
    Jia, Yingnan
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [33] Prognostic Value of Thyroglobulin Levels and Therapeutic 131I Whole-Body Scan after Initial 131I Ablation of Differentiated Thyroid Cancer
    Luo, Q.
    Yu, Y.
    Lu, H.
    Zhu, R.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 : S241 - S241
  • [34] Pulmonary sequestration: a 131I whole body scintigraphy false-positive result
    Spinapolice, Elena Giulia
    Chytiris, S.
    Fuccio, C.
    Leporati, P.
    Volpato, G.
    Villani, L.
    Trifiro, G.
    Chiovato, L.
    [J]. ANNALS OF NUCLEAR MEDICINE, 2014, 28 (07) : 683 - 687
  • [35] Incidental Finding of Endometrioid Adenocarcinoma of the Ovary on 131I Whole-Body Scan
    Rohani, Mohd Fazrin Mohd
    Hassan, Siti Zarina Amir
    [J]. CLINICAL NUCLEAR MEDICINE, 2022, 47 (01) : E20 - E22
  • [36] 131I Uptake in a Left Cerebral Infarct on Posttherapy Whole-Body Scan
    Ng, Cherie Wei Qi
    Cheng, Lenith Tai Jit
    Chua, Wei Ming
    Tang, Charlene Yu Lin
    [J]. CLINICAL NUCLEAR MEDICINE, 2024, 49 (08) : e415 - e416
  • [37] False-positive 131I whole-body scan and shrinkage of a pulmonary aspergilloma under 131I therapy in a patient with thyroid cancer
    Manka-Waluch, A
    Palmedo, H
    Tasci, S
    Biersack, HJ
    Bucerius, J
    [J]. THYROID, 2006, 16 (02) : 197 - 198
  • [38] Pulmonary sequestration: a 131I whole body scintigraphy false-positive result
    Elena Giulia Spinapolice
    S. Chytiris
    C. Fuccio
    P. Leporati
    G. Volpato
    L. Villani
    G. Trifirò
    L. Chiovato
    [J]. Annals of Nuclear Medicine, 2014, 28 : 683 - 687
  • [39] Post-Surgical 131I Ablation in Patients with Papillary Thyroid Cancer: The Role of Diagnostic 123I Whole Body Scan
    Iagaru, A.
    Mosci, C.
    Akatsu, H.
    Basina, M.
    Dosiou, C.
    McDougall, I.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S235 - S235
  • [40] CLINICAL APPLICATIONS OF LUNG SCANNING WITH MACRO-AGGREGATES OF 131I HUMAN SERUM ALBUMIN (MAA 131I)
    FERRINI, O
    PERRONI, GL
    BIASSONI, P
    BESTAGNO, M
    FRESCO, G
    [J]. JOURNAL OF NUCLEAR BIOLOGY AND MEDICINE, 1966, 10 (04): : 147 - &