Performance predictions of ground source heat pump system based on random forest and back propagation neural network models

被引:56
|
作者
Lu, Shilei [1 ]
Li, Qiaoping [1 ]
Bai, Li [2 ]
Wang, Ran [1 ]
机构
[1] Tianjin Univ, Sch Environm Sci & Engn, Tianjin 300350, Peoples R China
[2] Jilin Jianzhu Univ, Sch Municipal & Environm Engn, Changchun 130118, Jilin, Peoples R China
基金
国家重点研发计划;
关键词
GSHP system; Performance prediction; COP; EER; Random forest; Back propagation neural network; ENERGY PERFORMANCE; CLASSIFICATION; REGRESSION; DIAGNOSIS; SELECTION;
D O I
10.1016/j.enconman.2019.111864
中图分类号
O414.1 [热力学];
学科分类号
摘要
With rapid development of artificial intelligence, data-driven prediction models play an important role in energy prediction, fault detection, and diagnosis. This paper proposes an ensemble approach using random forest (RF) for hourly performance predictions of GSHP system. Two years of in situ data were collected in an educational building situated in severe cold area in China. Prediction models were established for performance indicators, and results indicate that the average error for COPs, COPu, EERs and EERu were all controlled within 5%. The model established by small amount of data can accurately predict long-term performance, thereby reducing time and difficulty of data collection. RF models, trained with different parameter settings were compared, results indicate that model accuracy was not very sensitive to variables numbers. The impact of input variables on prediction performance was analyzed, and importance ranking changed with period and performance indicators. By comparing the variable importance list, it was possible to establish which parameters were abnormal and lists of different periods can reflect whether the energy structure of building has changed. The overall superiority of RF was verified by comparing with back propagation neural network (BPNN) from robustness, interpretability, and efficiency. First, since GSHP system involving multiple indicators, the robustness, measured by average accuracy, was used to evaluate the accuracy level. According to CV-RMSE, robustness of RF is approximately 3.3% higher than that of BPNN. Second, RF is highly interpretive but BPNN is typical black box model. Finally, modeling complexity and training time of BPNN were much greater than RF.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Exergetic performance assessment of a ground-source heat pump drying system
    Kuzgunkaya, Ebru Hancioglu
    Hepbasli, Arif
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2007, 31 (08) : 760 - 777
  • [22] Heating performance of a ground source heat pump system installed in a school building
    Song, Jaedo
    Lee, Kwangho
    Jeong, Youngman
    Cheong, Seongir
    Lee, Jaekeun
    Hwang, Yujin
    Lee, Yeongho
    Lee, Donghyuk
    SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2010, 53 (01) : 80 - 84
  • [23] Performance Evaluation of a Hyperloop Ground Source Heat Pump System in a Residential Building
    Miao, Rui
    Yu, Yao
    Hu, Xiaoou
    Gordon, Richard A.
    ASHRAE TRANSACTIONS 2023, VOL 129, PT 1, 2023, 129 : 34 - 41
  • [24] Performance of a residential ground source heat pump system in sedimentary rock formation
    Han, Chanjuan
    Yu, Xiong
    APPLIED ENERGY, 2016, 164 : 89 - 98
  • [25] Heating performance of a ground source heat pump system installed in a school building
    Jaedo SONG
    Kwangho LEE
    Youngman JEONG
    Seongir CHEONG
    Jaekeun LEE
    Yujin HWANG
    Yeongho LEE
    Donghyuk LEE
    Science China(Technological Sciences) , 2010, (01) : 80 - 84
  • [26] Development of a design and performance prediction tool for the ground source heat pump system
    Nagano, Katsunori
    Katsura, Takao
    Takeda, Sayaka
    APPLIED THERMAL ENGINEERING, 2006, 26 (14-15) : 1578 - 1592
  • [27] Heating performance of a ground source heat pump system installed in a school building
    Jaedo Song
    Kwangho Lee
    Youngman Jeong
    Seongir Cheong
    Jaekeun Lee
    Yujin Hwang
    Yeongho Lee
    Donghyuk Lee
    Science in China Series E: Technological Sciences, 2010, 53 : 80 - 84
  • [28] Heating performance of a ground source heat pump system installed in a school building
    Jaedo SONG
    Kwangho LEE
    Youngman JEONG
    Seongir CHEONG
    Jaekeun LEE
    Yujin HWANG
    Yeongho LEE
    Donghyuk LEE
    Science China(Technological Sciences), 2010, 53 (01) : 80 - 84
  • [29] Performance Analysis of a Ground-Source Heat Pump System Using Mine Water as Heat Sink and Source
    Liu, Xiaobing
    Malhotra, Mini
    Walburger, Adam
    Skinner, Jack L.
    Blackketter, Donald M.
    ASHRAE TRANSACTIONS, VOL 122, PT 2, 2016, 122 : 160 - 172
  • [30] The performance prediction of ground source heat pump system based on monitoring data and data mining technology
    Yan, Lei
    Hu, Pingfang
    Li, Changhong
    Yao, Yu
    Xing, Lu
    Lei, Fei
    Zhu, Na
    ENERGY AND BUILDINGS, 2016, 127 : 1085 - 1095