Evaporation aided improvement for cooling performance of large scale natural draft dry cooling system

被引:18
|
作者
Huang, Xianwei [1 ]
Chen, Lin [1 ]
Yang, Lijun [1 ]
Du, Xiaoze [1 ]
Yang, Yongping [1 ]
机构
[1] North China Elect Power Univ, Key Lab Condit Monitoring & Control Power Plant E, Minist Educ, Sch Energy Power & Mech Engn, Beijing 102206, Peoples R China
基金
中国国家自然科学基金;
关键词
Natural draft dry cooling system; Air-cooled heat exchanger; Cooling performance; Evaporation aided cooling; Evaporation ratio; Unit back pressure; VERTICAL DELTA RADIATORS; THERMO-FLOW PERFORMANCE; WIND-BREAK WALLS; WATER SPRAY; INLET AIR; NUMERICAL-SIMULATION; WETTED MEDIA; CFD ANALYSIS; POWER-PLANT; TOWER;
D O I
10.1016/j.applthermaleng.2019.114350
中图分类号
O414.1 [热力学];
学科分类号
摘要
The cooling performance of natural draft dry cooling system gets deteriorated at high ambient temperature. In this work, the water spray cooling is proposed to chill the inlet air of air-cooled heat exchanger to improve the cooling performance of natural draft dry cooling system in hot summer days. Based on a typical 600 MW power generating unit, a numerical model coupled the water spray with dry cooling system is developed to evaluate the cooling performance of natural draft dry cooling system with evaporation aided cooling under windless and windy conditions. The results show that the cooling performance gets improved due to water spray evaporation although the total air flow rate decreases. The heat rejection for the leeward sector increases a lot for the conspicuous inlet air temperature drop, but decreases for the windward sectors. The complete evaporation is easier to be achieved near the windward sector, but the evaporation ratio is unfavorable at the wind speed of 8 m/s. The unit back pressure gradually decreases with increasing the spraying flow rate and has an average drop of 3 kPa with a relatively high evaporation ratio at the spraying flow rate of 0.25 kg/s.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Auxiliary heat exchanger layout for freeze-proofing and performance recovery of natural draft dry cooling system
    Yan, Jingbo
    Huang, Xianwei
    Huang, Wenhui
    Yang, Lijun
    Du, Xiaoze
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 150
  • [42] Natural draft direct dry cooling system performance at various application scales under windless and windy conditions
    Strydom, Wian
    Pretorius, Johannes
    Hoffmann, Jaap
    APPLIED THERMAL ENGINEERING, 2024, 248
  • [43] Annularly arranged air-cooled condenser to improve cooling efficiency of natural draft direct dry cooling system
    Kong, Yanqiang
    Wang, Weijia
    Huang, Xianwei
    Yang, Lijun
    Du, Xiaoze
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 118 : 587 - 601
  • [44] Tower Configuration Impacts on the Thermal and Flow Performance of Steel-Truss Natural Draft Dry Cooling System
    Guo, Huiqian
    Yang, Yue
    Cheng, Tongrui
    Zhou, Hanyu
    Wang, Weijia
    Du, Xiaoze
    ENERGIES, 2021, 14 (07)
  • [45] Investigation on the cooling performance of mechanical draft dry-wet hybrid cooling tower
    Zhao, Cuilin
    Wang, Mingwei
    Gao, Qi
    Cheng, Shen
    He, Suoying
    Zhao, Jifang
    Zhan, Jianwei
    Liu, Zhilan
    Geng, Zhe
    Zhang, Shuzhen
    Qi, Jianhui
    Gao, Ming
    Shi, Yuetao
    APPLIED THERMAL ENGINEERING, 2023, 228
  • [46] Evaluation of natural draft dry cooling system incorporating water spray air precooling
    Chen, Lin
    Huang, Xianwei
    Yang, Lijun
    Du, Xiaoze
    Yang, Yongping
    APPLIED THERMAL ENGINEERING, 2019, 151 : 294 - 307
  • [47] Novel method for improving the cooling performance of natural draft wet cooling towers
    Chen, Xuehong
    Sun, Fengzhong
    Chen, Youliang
    Gao, Ming
    APPLIED THERMAL ENGINEERING, 2019, 147 : 562 - 570
  • [48] MINIMUM SIZE OF NATURAL-DRAFT DRY COOLING TOWERS FOR LARGE POWER-PLANTS
    MOORE, FK
    MECHANICAL ENGINEERING, 1973, 95 (06) : 61 - 61
  • [49] Performance Analysis of an Updraft Tower System for Dry Cooling in Large-Scale Power Plants
    Liu, Haotian
    Weibel, Justin
    Groll, Eckhard
    ENERGIES, 2017, 10 (11):
  • [50] Performance improvement technique of natural draft dry cooling tower under ambient wind based on minimum mechanical energy dissipation
    Wang, Jinygyao
    Zhang, Wenjie
    Wei, Huimin
    Du, Xiaoze
    Xi, Xinming
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2025, 245