Blending in above ground storage tanks with side-entering agitators

被引:5
|
作者
Grenville, R. K. [1 ]
Giacomelli, J. J. [1 ]
VanOmmeren, G. J. [2 ]
Hastings, C. F. [1 ]
Walters, M. J. [1 ]
机构
[1] Philadelphia Mixing Solut Ltd, Palmyra, PA 17078 USA
[2] Rowan Univ, Dept Chem Engn, Glassboro, NJ USA
来源
关键词
Mixing; Petroleum storage; Side-entering; Propeller; Stratified; Blend time; TIME;
D O I
10.1016/j.cherd.2018.07.017
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The blending of fluids in large, above ground storage tanks is widely practiced in the petroleum industry yet there have been very few studies of this mixing operation. The most demanding application is found when the tank contents have been allowed to stratify creating a light and heavy layer. The blend time in this case is defined as the time taken for the density of the fluid to become axially homogeneous. Wesselingh (1975) measured blend times using brine and water to produce the heavy and light layers and measured conductivity changes to assess the blending process. He only looked at one propeller geometry but did study the effects of several important geometrical system properties, such as the ratio of propeller to vessel diameter and liquid depth to vessel diameter. The study reported here uses Wesselingh's technique but examines the blending performance of four commercially available propellers. The results show that the Advanced Pitch propeller sold by Philadelphia Mixing Solutions Ltd. and Mixing Solutions Ltd. is significantly more efficient than the competitors' propellers when compared based on energy usage. These results, and Wesselingh's, show that there are two operating regimes which are separated by a critical Froude number, Frc. At high Froude numbers (Fr >Fr-c) the dimensionless blend time is constant, and at lower Froude numbers (Fr < Fr-c) the dimensionless blend time is inversely proportional to Froude number. The implications for scale-up in both regimes are discussed. (C) 2018 Institution of Chemical Engineers. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:395 / 402
页数:8
相关论文
共 50 条
  • [41] Research on the Safety and Security Distance of Above-Ground Liquefied Gas Storage Tanks and Dispensers
    Kukfisz, Bozena
    Kuczynska, Aneta
    Piec, Robert
    Szykula-Piec, Barbara
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (02)
  • [42] ENHANCED SEISMIC FRAGILITY ANALYSIS OF UNANCHORED ABOVE-GROUND STEEL LIQUID STORAGE TANKS
    Hoang Nam Phan
    Paolacci, Fabrizio
    Alessandri, Silvia
    Phuong Hoa Hoang
    PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE, 2018, VOL 8, 2019,
  • [43] Deep neural networks for external corrosion classification in industrial above-ground storage tanks
    Alviz-Meza, Anibal
    Hadechini-Meza, Leidy L.
    Pena-Ballesteros, Dario Y.
    HELIYON, 2024, 10 (15)
  • [44] PARTICLE SEDIMENTATION IN MODEL TANK AND CRUDE-OIL STORAGE TANK WITH SIDE-ENTERING MIXER - CASE OF INSERTING ANGLE THETA=20-DEGREES
    KONNO, D
    OKITA, N
    KAGAKU KOGAKU RONBUNSHU, 1984, 10 (03) : 330 - 336
  • [45] Optimal Structural Design of Circular, Rotationally Molded, Above-Ground Polyethylene Water Storage Tanks
    Beneke, D. L.
    Thumkunta, J. R.
    Koen, D. J.
    PRACTICE PERIODICAL ON STRUCTURAL DESIGN AND CONSTRUCTION, 2011, 16 (02) : 62 - 66
  • [46] Assessment of an edge type settlement of above ground liquid storage tanks using a simple beam model
    Hamdan, M. N.
    Abuzeid, Osama
    Al-Salaymeh, Ahmed
    APPLIED MATHEMATICAL MODELLING, 2007, 31 (11) : 2461 - 2474
  • [47] Surface care for water storage tanks: Above the waterline
    Zienty, D
    WATER-ENGINEERING & MANAGEMENT, 1998, 145 (07): : 18 - 20
  • [48] Probabilistic evaluation of earthquake-induced sloshing wave height in above-ground liquid storage tanks
    Merino, R. J.
    Brunesi, E.
    Nascimbene, R.
    ENGINEERING STRUCTURES, 2020, 202
  • [49] THE EFFECT OF OFF-WALL CLEARANCE OF A SIDE-ENTERING IMPELLER ON THE MIXING OF PULP SUSPENSIONS IN A CYLINDRICAL STOCK CHEST
    Bhole, Manish R.
    Hui, Leo K.
    Gomez, Clara
    Bennington, Chad P. J.
    Dumont, Guy A.
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2011, 89 (05): : 985 - 995
  • [50] DESIGN OF GRATINGS FOR THE ROOFS OF ABOVE-GROUND CYLINDRICAL TANKS
    SCHNEIDER, P
    CHEMISCHE TECHNIK, 1980, 32 (05): : 273 - 274