Analysis of transducer effect sensitivity function in nonlinear ultrasound measurement system

被引:2
|
作者
Kourtiche, D. [1 ]
Nadi, M. [1 ]
Rouane, A. [1 ]
Chitnalah, A. [2 ]
机构
[1] Nancy Univ, Fac Sci & Tech, Lab Instrumentat Elect Nancy, Nancy, France
[2] Univ Cadi Ayad, Fac Sci, Marrakech Maroc, France
关键词
Nonlinear acoustic; B/A parameter; Second harmonic; Comparative method; Transducer sensitivity; BIOLOGICAL MEDIA; TRANSMISSION PARAMETERS; B/A MEASUREMENT;
D O I
10.1016/j.ndteint.2009.10.005
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
A procedure for measurement of the nonlinear B/A parameter using a simple comparative method is presented. A theoretical model of the measurement system is proposed. The sensitivity function of the measurement system is carried out and related to the electric and acoustic magnitudes. The optimal conditions were carried out with the aim to avoid sophisticated calculations of the transducers sensitivities. It has been shown that the sensitivity function can be kept close to the unit by a specific choice of the fundamental frequency. Indeed if the frequency of the source transducer is chosen lower than the resonance frequency we can avoid determining the sensitivities. Measurements have been carried out to validate the procedure in the frame of the theoretical aspects. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:145 / 151
页数:7
相关论文
共 50 条
  • [31] Simple, effective and high sensitivity transducer for force measurement of myofibrils
    Phan, Kien Nguyen
    Kobayashi, Takakazu
    SENSORS AND ACTUATORS A-PHYSICAL, 2008, 144 (02) : 389 - 393
  • [32] Improvement on the Transducer Sensitivity Measurement Results using Vibration Exciters
    Temba, M. L.
    Du, S.
    PROCEEDINGS OF THE 2017 INTERNATIONAL CONFERENCE ON ECONOMICS, FINANCE AND STATISTICS (ICEFS 2017), 2017, 26 : 319 - 325
  • [33] Measurement of electroacoustic transducer sensitivity in extreme hydrostatic pressure environments
    Brown, David A.
    Aikins, Eric K.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2023, 153 (03):
  • [34] Analysis of impulse response of rectangular ultrasound transducer
    Bu, Fanliang
    Cao, Peijie
    Cheng, Jingzhi
    Shengwu Yixue Gongchengxue Zazhi/Journal of Biomedical Engineering, 2000, 17 (04): : 425 - 428
  • [35] Effect of Ultrasound Transducer Frequency on Longitudinal Strain Measurement by 2d Speckle Tracking Echocardiography
    Iwakura, Katsuomi
    Okamura, Atsunori
    Koyama, Yasushi
    Inoue, Koichi
    Iwamoto, Mutsumi
    Nagai, Hiroyuki
    Hirao, Yuko
    Tanaka, Koji
    Oka, Takafumi
    Tanaka, Nobuaki
    Ninomiya, Yuichi
    Okada, Masato
    Sumiyoshi, Akinori
    Inoue, Hiroyuki
    Tanaka, Kota
    Takayasu, Kohtaro
    Fujii, Kenshi
    CIRCULATION, 2018, 138
  • [36] Analysis of an image-based transducer tracking system for 3D ultrasound
    Smith, WL
    Fenster, A
    MEDICAL IMAGING 2003: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2003, 5035 : 154 - 165
  • [37] A High Sensitivity Transparent Ultrasound Transducer Based on PMN-PT for Ultrasound and Photoacoustic Imaging
    Chen, Haoyang
    Mirg, Shubham
    Osman, Mohamed
    Agrawal, Sumit
    Cai, Jiacheng
    Biskowitz, Ryan
    Minotto, Josiah
    Kothapalli, Sri-Rajasekhar
    IEEE Sensors Letters, 2021, 5 (11):
  • [38] CALIBRATION SYSTEM FOR CATHETER TRANSDUCER PRESSURE MEASUREMENT
    MURRAY, RHS
    HOWE, NA
    BIOMEDICAL ENGINEERING, 1976, 11 (05) : 180 - 182
  • [39] The effect of nonlinear effects on the measurement of the absorption coefficient of ultrasound in a liquid by the pulse method
    Kononenko, V. S.
    Shatskii, A. V.
    Tiranin, V. E.
    VESTNIK SAMARSKOGO GOSUDARSTVENNOGO TEKHNICHESKOGO UNIVERSITETA-SERIYA-FIZIKO-MATEMATICHESKIYE NAUKI, 2005, (38): : 96 - 99
  • [40] A dual transducer ultrasound system for quantitative Doppler measurements
    Ricci, Stefano
    Bassi, Luca
    Dallai, Alessandro
    Boni, Enrico
    Tortoli, Piero
    2007 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, PROCEEDINGS, VOLS 1-8, 2007, : 2718 - 2723