A procedure for measurement of the nonlinear B/A parameter using a simple comparative method is presented. A theoretical model of the measurement system is proposed. The sensitivity function of the measurement system is carried out and related to the electric and acoustic magnitudes. The optimal conditions were carried out with the aim to avoid sophisticated calculations of the transducers sensitivities. It has been shown that the sensitivity function can be kept close to the unit by a specific choice of the fundamental frequency. Indeed if the frequency of the source transducer is chosen lower than the resonance frequency we can avoid determining the sensitivities. Measurements have been carried out to validate the procedure in the frame of the theoretical aspects. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:145 / 151
页数:7
相关论文
共 50 条
  • [1] Ultrasound transducer sensitivity in non linear parameter measurement
    Kourtiche, Djilali
    Nadi, Mustapha
    Rouane, Amar
    Chitnalah, Ahmed
    PROCEEDINGS OF THE THIRD INTERNATIONAL CONFERENCE ON SENSING TECHNOLOGY, 2008, : 359 - +
  • [2] Repetitive learning control for the correction of linear and nonlinear transducer measurement errors: Sensitivity analysis of the method
    Hamrita, TK
    CONFERENCE RECORD OF THE 1998 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-3, 1998, : 1632 - 1637
  • [3] Measurement methods of ultrasonic transducer sensitivity
    Xiao, Dingguo
    Fan, Qiong
    Xu, Chunguang
    Zhang, Xiuhua
    ULTRASONICS, 2016, 68 : 150 - 154
  • [4] Measurement of transducer directivity function
    Leeman, S
    Healey, AJ
    Costa, ET
    Nicacio, H
    Dantas, R
    Maia, J
    MEDICAL IMAGING 2001: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2001, 4325 : 47 - 53
  • [5] Improvement of Sensitivity of Capacitive Micromachined Ultrasound Transducer
    Wang, Yifan
    Liu, Shuo
    3RD INTERNATIONAL CONFERENCE ON AIR POLLUTION AND ENVIRONMENTAL ENGINEERING, 2020, 631
  • [6] Water temperature measurement using a novel fiber optic ultrasound transducer system
    Zhou, Jingcheng
    Wu, Nan
    Wang, Xingwei
    Liu, Yuqian
    Ma, Tong
    Coxe, Daniel
    Cao, Chengyu
    2015 IEEE INTERNATIONAL CONFERENCE ON INFORMATION AND AUTOMATION, 2015, : 2316 - 2319
  • [7] Multilayer Array Transducer for Nonlinear Ultrasound Imaging
    Owen, Neil R.
    Kaczkowski, Peter J.
    Li, Tong
    Gross, Dan
    Postlewait, Steven M.
    Curra, Francesco P.
    10TH INTERNATIONAL SYMPOSIUM ON THERAPEUTIC ULTRASOUND (ISTU 2010), 2011, 1359 : 206 - 210
  • [8] Sensitivity enhancement using nonlinear optimal wavelet thresholding for two-dimensional medical ultrasound transducer
    Biomedical Eng. Lab., Department of Electronic Engineering, Chinese University of Hong Kong, Shatin, N.T., Hong Kong
    BIOMED. ENG. APPL. BASIS COMMUN., 2 (18-27):
  • [9] Development of Pressure Control System of Contact Transducer for Measurement of Ultrasonic Nonlinear Parameter
    Lee, In-Ho
    Son, Dae-Soo
    Choi, Ik-Hwang
    Lee, Tae-Hun
    Jhang, Kyung-Young
    JOURNAL OF THE KOREAN SOCIETY FOR NONDESTRUCTIVE TESTING, 2007, 27 (06) : 576 - 581
  • [10] ON BEHAVIOR OF SOLUTIONS TO A CHEMOTAXIS SYSTEM WITH A NONLINEAR SENSITIVITY FUNCTION
    Senba, Takasi
    Fujie, Kentarou
    PROCEEDINGS OF EQUADIFF 2017 CONFERENCE, 2017, : 45 - 52