Brain Computed Tomography Compared with Facial 3-Dimensional Computed Tomography for Diagnosis of Facial Fractures

被引:5
|
作者
Lee, Sun Hwa [1 ]
Yun, Seong Jong [2 ]
Ryu, Seokyong [1 ]
Choi, Seoung Won [1 ]
Kim, Hye Jin [1 ]
Kang, Tae Kyug [1 ]
Oh, Sung Chan [1 ]
Cho, Suk Jin [1 ]
机构
[1] Inje Univ, Coll Med, Sanggye Paik Hosp, Dept Emergency Med, Seoul, South Korea
[2] Republ Korea Air Force, Aerosp Med Ctr, Dept Radiol, POB 335-21,635 Danjae Ro, Cheongwon Gun 363849, Chungcheongbuk, South Korea
来源
JOURNAL OF PEDIATRICS | 2017年 / 184卷
关键词
CT; RADIATION; MANAGEMENT; CHILDREN; EXPOSURE; CANCER; HEAD;
D O I
10.1016/j.jpeds.2017.01.036
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Objectives To compare the detection of facial fractures and radiation dose between brain computed tomography (CT) and facial 3-dimensional (3D) CT in pediatric patients who have experienced a trauma. Study design Four hundred pediatric patients who experienced a trauma and underwent immediate brain CT and facial 3D CT between January 2016 and June 2016 were included in this retrospective study. Two reviewers independently analyzed and determined the presence of the facial fractures of 8 anatomic regions based on brain CT and facial 3D CT over a 1-week interval. Suggested treatment decisions for facial fractures seen on brain CT and facial 3D CT were evaluated by one physician. The facial 3D CT scans, interpreted by a senior radiologist, were considered as the reference standard. Diagnostic performance, radiation dose, and interobserver agreement of the CT scans were evaluated. Results Brain CT showed a high sensitivity (94.1%-96.5%), high specificity (99.7%-100%), and high accuracy (98.8%-99.0%) in both reviewers, and performed as well as did facial 3D CT (P >= .25). The suggested treatment decision was not different between the brain CT and facial 3D CT findings. The agreements between the reference standard and the reviewers, and between reviewers 1 and 2 were excellent (k = 0.946-0.993). The mean effective radiation doses used in brain CT (3.6 mSv) were significantly lower than those in brain CT with facial 3D CT (5.5 mSv) (P < .001). Conclusions Brain CT showed acceptable diagnostic performance and can be used as the first-line imaging tool in the workup of pediatric patients with suspected facial fractures.
引用
收藏
页码:32 / +
页数:8
相关论文
共 50 条
  • [41] COMPUTED-TOMOGRAPHY DIAGNOSIS OF ACUTE FACIAL SWELLING IN AN ADULT HEMOPHILIAC
    KUHLMANN, TP
    ABIDIN, MR
    NEAL, DA
    ANNALS OF EMERGENCY MEDICINE, 1989, 18 (06) : 681 - 683
  • [42] The Role of Cranial Computed Tomography in the Diagnosis of Acute Facial Nerve Paralysis
    Dafotakis, M.
    Nikoubashman, O.
    Rattay, T.
    Eickhoff, S. B.
    Reich, A.
    Schulz, J. B.
    Schiefer, J.
    KLINISCHE NEUROPHYSIOLOGIE, 2014, 45 (03) : 164 - 167
  • [43] Anthropometric Comparison of 3-Dimensional Facial Scan Taken With a Low-Cost Facial Scanner With Cone-Beam Computed Tomography Scan
    Aljawad, Hussein
    Lim, Hoi-Jeong
    Lee, Kyungmin Clara
    JOURNAL OF CRANIOFACIAL SURGERY, 2023, 34 (05) : 1456 - 1458
  • [44] COMPUTED TOMOGRAPHY OF TRAUMA INVOLVING BRAIN AND FACIAL SKULL (CRANIOFACIAL INJURIES)
    CLAUSSEN, CD
    LOHKAMP, FW
    KRASTEL, A
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1977, 1 (04) : 472 - 481
  • [45] Multidetector-row computed tomography and 3-dimensional computed tomography imaging of small bowel neoplasms - Current concept in diagnosis
    Horton, KM
    Fishman, EK
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2004, 28 (01) : 106 - 116
  • [46] COMPUTED OR CONVENTIONAL TOMOGRAPHY - COMPARATIVE INVESTIGATIONS IN FACIAL AND FRONTAL SKULL BASE FRACTURES
    MEES, K
    HUBSCH, T
    LARYNGOLOGIE RHINOLOGIE OTOLOGIE VEREINIGT MIT MONATSSCHRIFT FUR OHRENHEILKUNDE, 1985, 64 (07): : 335 - 337
  • [47] INDICATIONS FOR THE USE OF HIGH-RESOLUTION COMPUTED-TOMOGRAPHY FOR THE DIAGNOSIS OF MAXILLO-FACIAL FRACTURES
    SCHROEDER, HG
    LUTCKE, A
    ARCHIVES OF OTO-RHINO-LARYNGOLOGY-ARCHIV FUR OHREN-NASEN-UND KEHLKOPFHEILKUNDE, 1985, 241 (02): : 129 - 129
  • [48] 3-DIMENSIONAL COMPUTED-TOMOGRAPHY OF THE MUMMY WENUHOTEP
    PICKERING, RB
    CONCES, DJ
    BRAUNSTEIN, EM
    YURCO, F
    AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 1990, 83 (01) : 49 - 55
  • [49] 3-DIMENSIONAL COMPUTED-TOMOGRAPHY IN MAXILLOFACIAL TRAUMA
    DEMARINO, DP
    STEINER, E
    POSTER, RB
    KATZBERG, RW
    HENGERER, AS
    HERMAN, GT
    WAYNE, WS
    PROSSER, DC
    ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 1986, 112 (02) : 146 - 150
  • [50] 3-DIMENSIONAL COMPUTED-TOMOGRAPHY IN ORBITAL OSTEOMA
    OHTSUKA, K
    TAKEDA, M
    OKAGAWA, T
    NAKAGAWA, T
    ASAKURA, K
    KATAGIRI, Y
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1988, 106 (04) : 502 - 504