Which Technique Is Better for Detection of Right-to-Left Shunt in Patients with Patent Foramen Ovale: Comparing Contrast Transthoracic Echocardiography with Contrast Transesophageal Echocardiography

被引:17
|
作者
Yue Li [1 ]
Zhai Ya-nan [1 ]
Wei Li-qun [1 ]
机构
[1] Peoples Liberat Army Gen Hosp, Ultrasound Dept Chinese, Beijing 100853, Peoples R China
关键词
patent foramen ovale; right-to-left shunt; contrast echocardiography; transthoracic echocardiography; transesophageal echocardiography; AGITATED SALINE CONTRAST; TRANSCRANIAL DOPPLER; RECOMMENDATIONS; DIAGNOSIS; EMBOLISM; CLOSURE;
D O I
10.1111/echo.12523
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: At present there is no consensus on which technique is more suitable for the detection of right-to-left shunt (RLS) in patients with patent foramen ovale (PFO). The aim of study was to compare the efficacy of contrast transthoracic echocardiography (cTTE) and contrast transesophageal echocardiography (cTEE) in the detection of RLS. Methods: A prospective study was undertaken in 29 patients with PFO. Both cTTE with harmonic imaging modality and cTEE with fundamental imaging modality were performed for all the patients. The severity of RLS were semiquantitatively assessed with a four-level grade system by scaling the numbers of microbubbles (MBs) in the left atrium after complete opacification of the right atrium within the first 3 cardiac cycles. Level 1 represents no MBs, indicating no RLS. Level 2, <= 10 MBs, indicating mild RLS. Level 3, 11-30 MBs, indicating moderate RLS and Level 4, >30 MBs, indicating severe RLS. Results: Contrast TTE demonstrated significantly higher sensitivity for detection of RLS than cTEE (86% vs. 56%, P < 0.05). For cTTE, there were 4, 1, 5, and 19 cases determined at levels 1, 2, 3, and 4, respectively, whereas for the same group of patients 13, 2, 6, and 7 cases were identified by cTEE at levels 1, 2, 3, and 4, respectively. The severity of RLS detected by cTTE was significantly greater than that by cTEE (P < 0.01). Conclusions: Contrast TTE is more efficacious in the detection of RLS than cTEE. The former can be used as an alternative to the latter in clinical practice.
引用
收藏
页码:1050 / 1055
页数:6
相关论文
共 50 条
  • [21] Enhanced detection of patent foramen ovale by systematic transthoracic saline contrast echocardiography
    Lam, Yat-Yin
    Yu, Cheuk-Man
    Zhang, Qing
    Yan, Bryan P.
    Yip, Gabriel Wai-Kwok
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2011, 152 (01) : 24 - 27
  • [22] Contrast transthoracic echocardiography versus transcranial Doppler for patent foramen ovale detection
    Corrado, Giovanni
    Massironi, Laura
    Torta, Daniela
    Rigo, Fausto
    Beretta, Sandro
    Sansalone, Dario
    Zenoni, Eleonora
    Mantero, Antonio
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2011, 150 (02) : 235 - 237
  • [23] RIGHT-TO-LEFT SHUNT ACROSS A PATENT FORAMEN OVALE CAUSED BY CARDIAC-TAMPONADE - DIAGNOSIS BY TRANSESOPHAGEAL ECHOCARDIOGRAPHY
    THOMPSON, RC
    FINCK, SJ
    LEVENTHAL, JP
    SAFFORD, RE
    MAYO CLINIC PROCEEDINGS, 1991, 66 (04) : 391 - 394
  • [24] Live Biplane Transesophageal Echocardiography Improves Detection of Right-to-Left Shunts Through Patent Foramen Ovale
    Xu, Chunyan
    Zhang, Yongxing
    Peng, Yuan
    Zhao, Ruohan
    Xie, Mingxing
    Fang, Lingyun
    Lv, Qing
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2024, 37 (06) : 643 - 645
  • [25] TRANSESOPHAGEAL ECHOCARDIOGRAPHY AND CONTRAST-TCD IN THE DETECTION OF A PATENT FORAMEN OVALE - EXPERIENCES WITH 111 PATIENTS
    KLOTZSCH, C
    JANSSEN, G
    BERLIT, P
    NEUROLOGY, 1994, 44 (09) : 1603 - 1606
  • [26] Modified Method of Contrast Transthoracic Echocardiography for the Diagnosis of Patent Foramen Ovale
    Zhao, Enfa
    Du, Yajuan
    Xie, Hang
    Zhang, Yushun
    BIOMED RESEARCH INTERNATIONAL, 2019, 2019
  • [27] Artificial intelligence diagnosis of patent foramen ovale in contrast transthoracic echocardiography
    Sheng, Yuanyuan
    Chen, Lixin
    Gu, Mengjie
    Luo, Shuyu
    Huang, Yuxiang
    Lin, Xiaoxuan
    Liu, Xiaohua
    Liu, Qian
    Zhong, Xiaofang
    Peng, Guijuan
    Li, Jian
    Shi, Bobo
    Wang, Lin
    Xu, Jinfeng
    Ning, Zhaohui
    Liu, Yingying
    ISCIENCE, 2024, 27 (11)
  • [28] THE COUGH TEST IS SUPERIOR TO THE VALSALVA MANEUVER IN THE DELINEATION OF RIGHT-TO-LEFT SHUNTING THROUGH A PATENT FORAMEN OVALE DURING CONTRAST TRANSESOPHAGEAL ECHOCARDIOGRAPHY
    STODDARD, MF
    KEEDY, DL
    DAWKINS, PR
    HARVEY, D
    SHEPHERD, M
    AMERICAN HEART JOURNAL, 1993, 125 (01) : 185 - 189
  • [29] Optimization of patent foramen ovale detection by contrast transthoracic echocardiography using harmonic imaging
    Brochet, E.
    Lepage, L.
    Juliard, J. -M.
    Aubry, P.
    Vahanian, A.
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2008, 101 (04) : 199 - 201
  • [30] Enhanced detection of patent foramen ovale by transthoracic contrast echocardiography using harmonic imaging
    Ha, JW
    Shin, MS
    Kang, SM
    Jang, KJ
    Byun, K
    Rim, SJ
    Chung, NS
    Cho, SY
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 477A - 477A