Enhancement of the multi-channel continuous monitoring system through the use of Xenorhabdus luminescens lux fusions

被引:7
|
作者
Lee, JH [1 ]
Mitchell, RJ [1 ]
Gu, MB [1 ]
机构
[1] K JIST, Natl Res Lab Environm Biotechnol, Dept Environm Sci & Engn, Kwangju 500712, South Korea
来源
BIOSENSORS & BIOELECTRONICS | 2004年 / 20卷 / 03期
关键词
multi-channel continuous monitoring system; Xenorhabdus luminescens; thermo-lux strains; bioluminescence; oxidative stress;
D O I
10.1016/j.bios.2004.02.019
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The enhancement of the multi-channel continuous toxicity monitoring system developed previously was studied. To achieve better and more stable results from the system, the use of thermo-lux fusion strains that express the luxCDABE genes from Xenorhabdus luminescens was evaluated. A total of six recombinant Escherichia coli strains with the promoters front three oxidative-stress responsive genes, i.e. the katG. sodA and pqi-5 genes, fused to either the lux genes from Vibrio fischeri or X. luminescens were characterized and their responses to different chemicals compared. It was found that the basal level bioluminescence (BL) from the thermo-lux fusion strains was always higher while that of the 1 fischeri lux strains were always near or below the lower limit of detection of the system. For example, the katG::V.fischeri lux strain, DPD2511, gave no discernible response due to its low level expression while a fusion of the katG promoter with the X. luminescens lux operon was clearly responsive and capable of detecting hydrogen peroxide down to about 1 ppm. The use of the thermo-lux strains found them to be as sensitive as the V.fischeri lux strains while providing a brighter, more stable basal level bioluminescence, making the analysis and monitoring of water-borne toxicity more reliable. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:475 / 481
页数:7
相关论文
共 50 条
  • [31] A Multi-Channel Temperature Monitoring System for Inverter-Fed Electrical Machines
    Phuc, Pieter Nguyen
    Bozalakov, Dimitar V.
    Vansompel, Hendrik
    Stockman, Kurt
    Crevecoeur, Guillaume
    45TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2019), 2019, : 856 - 861
  • [32] Design of Multi-Channel Electric Energy Metering and Charge-Monitoring System
    Dong, Wenjie
    Zhang, He
    CONFERENCE PROCEEDINGS OF 2017 3RD IEEE INTERNATIONAL CONFERENCE ON CONTROL SCIENCE AND SYSTEMS ENGINEERING (ICCSSE), 2017, : 391 - 395
  • [33] Printer port based, low-cost, multi-channel monitoring system
    Suresh, K
    ELECTRONICS WORLD, 2005, 111 (1827): : 44 - 45
  • [34] A Prototype GUI for the Multi-channel Sensor Data Acquisition and Monitoring System of KTX
    Dong, Lei
    Song, Kezhu
    Yang, Junfeng
    Cao, Ping
    Mao, Di
    Lv, Wengui
    2012 18TH IEEE-NPSS REAL TIME CONFERENCE (RT), 2012,
  • [35] A unconstrained multi-channel heart rate monitoring system for exercising rehabilitation patients
    Park, Junho
    Cho, Jongman
    Nam, Taewoo
    Choi, Junghyeon
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 3512 - 3515
  • [36] A MICROPROCESSOR BASED, MULTI-CHANNEL LOW-TEMPERATURE MONITORING-SYSTEM
    KUIPER, BW
    VANDIJK, MHH
    CRYOGENICS, 1982, 22 (12) : 668 - 670
  • [37] Fiber optic multi-channel protein detector for use in preparative continuous annular chromatography
    Apostolidis, A
    Lehmann, H
    Schwotzer, G
    Willsch, R
    Prior, A
    Wolfgang, R
    Klimant, I
    Wolfbeis, OS
    JOURNAL OF CHROMATOGRAPHY A, 2002, 967 (02) : 183 - 189
  • [38] Strenuous exercise-tolerance stretchable dry electrodes for continuous multi-channel electrophysiological monitoring
    Xie, Ruijie
    Li, Qingsong
    Teng, Lijun
    Cao, Zhengshuai
    Han, Fei
    Tian, Qiong
    Sun, Jing
    Zhao, Yang
    Yu, Mei
    Qi, Dianpeng
    Guo, Peizhi
    Li, Guanglin
    Huo, Fengwei
    Liu, Zhiyuan
    NPJ FLEXIBLE ELECTRONICS, 2022, 6 (01)
  • [39] Strenuous exercise-tolerance stretchable dry electrodes for continuous multi-channel electrophysiological monitoring
    Ruijie Xie
    Qingsong Li
    Lijun Teng
    Zhengshuai Cao
    Fei Han
    Qiong Tian
    Jing Sun
    Yang Zhao
    Mei Yu
    Dianpeng Qi
    Peizhi Guo
    Guanglin Li
    Fengwei Huo
    Zhiyuan Liu
    npj Flexible Electronics, 6
  • [40] Design of WSN multi-channel sink node for widespread real-time continuous monitoring
    Wang, Z. (wzl_job@yahoo.com.cn), 1600, Nanjing University of Aeronautics an Astronautics (33):