The role of brachytherapy and cutting balloon™ angioplasty in the current treatment of stent restenosis

被引:3
|
作者
Bonan, R [1 ]
机构
[1] Inst Cardiol Montreal, Montreal, PQ H1T 1C8, Canada
关键词
vascular brachytherapy (VBT); gamma and beta radiation; in-stent restenosis;
D O I
10.1097/00019501-200409000-00004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The Gamma I, START and INHIBIT trials conclusively demonstrate the feasibility, safety and efficacy of intracoronary radiation as the treatment of choice for stent restenosis. Further reports confirm this finding and extend the indications. Vascular brachytherapy should be made available for all patients with diffuse stent restenosis. Specific devices such as cutting balloons may improve the procedure but does not seem to have an impact alone on the evolution. (C) 2004 Lippincott Williams Wilkins.
引用
收藏
页码:319 / 325
页数:7
相关论文
共 50 条
  • [31] Mechanism of cutting balloon angioplasty for in-stent restenosis: An intravascular ultrasound study
    Montorsi, P
    Galli, S
    Fabbiocchi, F
    Loaldi, A
    Grancini, L
    Ravagnani, P
    Trabattoni, D
    Cozzi, S
    Grasselli, D
    Bartorelli, AL
    CIRCULATION, 2001, 104 (17) : 616 - +
  • [32] Preliminary experience with cutting balloon angioplasty for iliac artery in-stent restenosis
    Tsetis, Dimitrios
    Belli, Anna Maria
    Morgan, Robert
    Basile, Antonio
    Kostas, Theodoros
    Manousaki, Eirini
    Katsamouris, Asterios
    Gourtsoyiannis, Nicholas
    JOURNAL OF ENDOVASCULAR THERAPY, 2008, 15 (02) : 193 - 202
  • [33] Results of cutting balloon angioplasty for stent restenosis. Japanese multicenter registry
    Nakamura, M
    Suzuki, T
    Matsubara, T
    Kobayashi, T
    Muramatsu, T
    Asakura, Y
    Chin, W
    Nishikawa, H
    Takayama, M
    Yamaguchi, T
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 235A - 235A
  • [34] Mechanisms and results of balloon angioplasty for the treatment of in-stent restenosis
    Mehran, R
    Mintz, GS
    Popma, JJ
    Pichard, AD
    Satler, LF
    Kent, KM
    Griffin, J
    Leon, MB
    AMERICAN JOURNAL OF CARDIOLOGY, 1996, 78 (06): : 618 - 622
  • [35] Mechanism of cutting balloon angioplasty for in-stent restenosis: An intravascular ultrasound study
    Montorsi, P
    Galli, S
    Fabbiocchi, F
    Loaldi, A
    Trabattoni, D
    Grancini, L
    Cozzi, S
    Ravagnani, P
    Parodi, O
    Bartorelli, AL
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2002, 56 (02) : 166 - 173
  • [36] Cutting balloon angioplasty versus rotational atherectomy for treatment of diffuse in-stent restenosis: multicentre diffuse in-stent restenosis registry in Japan
    Nakamura, S
    Hirose, M
    Miyauchi, T
    Kanazawa, A
    Hozawa, K
    Makishima, N
    Nakamura, S
    Koyama, J
    EUROPEAN HEART JOURNAL, 2004, 25 : 310 - 310
  • [37] Mechanisms of cutting-balloon angioplasty in the treatment of in-stent restenosis:: A volumetric intravascular ultrasound study
    Schiele, TM
    König, A
    Rieber, J
    Baylacher, M
    Stempfle, HU
    Theisen, K
    Klauss, V
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 82A - 83A
  • [38] Refractory stent restenosis following balloon angioplasty
    Yokoi, H
    Tamura, T
    Nakagawa, Y
    Hamasaki, N
    Kimura, T
    Nosaka, H
    Nobuyoshi, M
    CIRCULATION, 1999, 100 (18) : 307 - 307
  • [39] Comparison of cutting balloon angioplasty and drug-eluting stent for focal in-stent restenosis.
    Lee, SR
    Jeong, MH
    Hong, YJ
    Kim, JH
    Kim, W
    Cho, JG
    Ahn, YK
    Park, JC
    Kang, JC
    AMERICAN JOURNAL OF CARDIOLOGY, 2006, 97 (8B): : 28D - 28D
  • [40] Cutting balloon angioplasty for carotid in-stent restenosis: Case reports and review of the literature
    Shah, Qaisar A.
    Georgiadis, Alexandros L.
    Suri, M. Fareed K.
    Rodriguez, Gustavo J.
    Qureshi, Adnan I.
    JOURNAL OF NEUROIMAGING, 2008, 18 (04) : 428 - 432