Real-Time Beam Monitor for Charged Particle Medical Accelerators

被引:8
|
作者
Leggieri, Alberto [1 ,2 ]
Passi, Davide [1 ]
di Paolo, Franco [1 ]
Ciccotelli, Alessia [2 ]
De Stefano, Silvia [2 ]
Marangoni, Filippo [2 ]
Felici, Giuseppe [2 ]
机构
[1] Univ Roma Tor Vergata, Dept Elect Engn, Via Politecn 1, I-00133 Rome, Italy
[2] SIT Sordina IORT Technol SpA, I-04011 Aprilia, LT, Italy
关键词
Accelerator instrumentation; beam current monitor; medical applications; microwave devices; radiation detectors;
D O I
10.1109/TNS.2015.2504403
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A novel real-time charged particle detector for medical accelerators is proposed in this paper. The system, by means of a passive resonant cavity, performs a non destructive measurement of the beam current and provides a real time monitoring of the absorbed dose delivered to the patient. The system complies with requirements of the relevant International Standards for being used as a Radiation Detector for Charged Particles. The formulated theory allows the system design versus the accelerator features by providing analytical formulas and a development strategy. A prototype has been realized and tested in order to check the compliance with the expected behavior in the operating conditions of the Medical Accelerator. The system has been proved to be equivalent to the standard ionization based monitor chambers, furthermore offering several advantages: the absence of bias high voltage, more compactness, small size and the fact that this system measures the physical observable quantity directly related with the dose, the beam current.
引用
收藏
页码:869 / 877
页数:9
相关论文
共 50 条
  • [1] The application of a beam profile monitor as a beam current integrator for charged particle accelerators
    Chavez, E. R.
    Huerta, A.
    Macias, R.
    Barron-Palos, L.
    Andrade, E.
    Ortiz, M. E.
    Monroy, R.
    Moreno, E.
    Murillo, G.
    Policroniades, R.
    Varela, A.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (03): : 1159 - 1163
  • [2] Efficient and Enhanced QA Testing of Linear Accelerators Using a Real-Time Beam Monitor
    Jung, J.
    Farrokhkish, M.
    Norrlinger, B.
    Wang, Y.
    Heaton, R.
    Jaffray, D.
    Islam, M.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3415 - 3415
  • [3] A real-time intercepting beam-profile monitor for a medical cyclotron
    Hendriks, C.
    Uittenbosch, T.
    Cameron, D.
    Kellogg, S.
    Gray, D.
    Buckley, K.
    Schaffer, P.
    Verzilov, V.
    Hoehr, C.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2013, 84 (11):
  • [4] A REAL-TIME NEUTRON BEAM MONITOR
    BECKER, JA
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 211 (2-3): : 297 - 300
  • [5] SENSITIVE LONG PULSE BEAM CHARGE MONITOR FOR USE WITH CHARGED-PARTICLE ACCELERATORS
    VOJNOVIC, B
    [J]. RADIATION PHYSICS AND CHEMISTRY, 1987, 29 (06) : 409 - 413
  • [6] Charged particle beam diagnostics for the fair accelerators
    D. A. Liakin
    T. V. Kulevoy
    [J]. Atomic Energy, 2012, 112 : 100 - 109
  • [7] Charged particle beam diagnostics for the fair accelerators
    Liakin, D. A.
    Kulevoy, T. V.
    [J]. ATOMIC ENERGY, 2012, 112 (02) : 100 - 109
  • [8] A SENSITIVE SINGLE-PULSE BEAM CHARGE MONITOR FOR USE WITH CHARGED-PARTICLE ACCELERATORS
    VOJNOVIC, B
    [J]. RADIATION PHYSICS AND CHEMISTRY, 1984, 24 (5-6): : 517 - 522
  • [9] Application of real-time digitization techniques in beam measurement for accelerators
    Zhao, Lei
    Zhan, Lin-Song
    Gao, Xing-Shun
    Liu, Shu-Bin
    An, Qi
    [J]. CHINESE PHYSICS C, 2016, 40 (04)
  • [10] Application of real-time digitization techniques in beam measurement for accelerators
    赵雷
    占林松
    高兴顺
    刘树彬
    安琪
    [J]. Chinese Physics C, 2016, 40 (04) : 74 - 82