Insulinoma: Correlation of short-TI inversion-recovery (STIR) imaging and histopathologic findings

被引:15
|
作者
Mori, M [1 ]
Fukuda, T [1 ]
Nagayoshi, K [1 ]
Kohzaki, S [1 ]
Matsunaga, N [1 ]
Hayashi, K [1 ]
Motojima, K [1 ]
Kanematsu, T [1 ]
机构
[1] NAGASAKI UNIV,SCH MED,DEPT SURG 2,NAGASAKI 852,JAPAN
来源
ABDOMINAL IMAGING | 1996年 / 21卷 / 04期
关键词
pancreas; insulinoma; MRI; STIR image;
D O I
10.1007/s002619900077
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
We studied the value of short-TI inversion-recovery (STIR) imaging for the localization of pancreatic insulinoma. Four patients (three women and one man aged 35-65 years) with surgically proven insulinoma were included in this study, All patients were examined by MR imaging with spin echo (SE) and STIR sequences, The STIR images were compared with the histopathologic findings in each case, In two patients, the tumors were markedly hyperintense on STIR images, and a 5-mm insulinoma was depicted only by this imaging method in one of the two. In the other two patients, 10-mm insulinomas were only slightly hyperintense on STIR images, The latter tumors had a higher content of collagen fibers than the former, indicating that the amount of collagen influences the signal intensity of insulinoma, Despite some limitations, STIR imaging is a useful noninvasive method for the localization of pancreatic insulinoma.
引用
收藏
页码:337 / 341
页数:5
相关论文
共 50 条
  • [41] NONTRAUMATIC PEDIATRIC MUSCULOSKELETAL MR-IMAGING - COMPARISON OF CONVENTIONAL AND FAST-SPIN-ECHO SHORT INVERSION TIME INVERSION-RECOVERY TECHNIQUE
    WEINBERGER, E
    SHAW, DWW
    WHITE, KS
    WINTERS, WD
    STARK, JE
    NAZARSTEWART, V
    HINKS, RS
    RADIOLOGY, 1995, 194 (03) : 721 - 726
  • [42] MR EVALUATION OF VERTEBRAL METASTASES - T1-WEIGHTED, SHORT-INVERSION-TIME INVERSION-RECOVERY, FAST SPIN-ECHO, AND INVERSION-RECOVERY FAST SPIN-ECHO SEQUENCES
    MEHTA, RC
    MARKS, MP
    HINKS, RS
    GLOVER, GH
    ENZMANN, DR
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1995, 16 (02) : 281 - 288
  • [43] IMPROVED MR VENOGRAPHY - USE OF FAST SHORT INVERSION TIME INVERSION-RECOVERY TECHNIQUE IN EVALUATION OF VENOUS ANGIOMAS
    SAKS, AM
    PATERSON, FC
    IRVINE, AT
    AYERS, BA
    BURNAND, KG
    RADIOLOGY, 1995, 194 (03) : 908 - 911
  • [44] THE USE OF SHORT-T1 INVERSION-RECOVERY SEQUENCES IN THE EVALUATION OF SPINAL PATHOLOGY
    WORTHINGTON, BS
    GIBSON, M
    PRESTON, BJ
    MULHOLLAND, RC
    SZYPRYT, P
    BRITISH JOURNAL OF RADIOLOGY, 1987, 60 (716): : 812 - 812
  • [45] ENDORECTAL SURFACE COIL MR IMAGING OF PROSTATIC-CARCINOMA WITH THE INVERSION-RECOVERY SEQUENCE
    PARIVAR, F
    RAJANAYAGAM, V
    WALUCH, V
    ETO, RT
    JONES, LW
    ROSS, BD
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (06): : 657 - 664
  • [46] Multislice double inversion-recovery black-blood imaging with simultaneous slice reinversion
    Yarnykh, VL
    Yuan, C
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (04) : 478 - 483
  • [47] Distortion correction for a double inversion-recovery sequence with an echo-planar imaging readout
    Meara, Simon J. P.
    Ernbleton, Karl V.
    Parker, Geoffrey J. M.
    MAGNETIC RESONANCE IMAGING, 2008, 26 (07) : 943 - 953
  • [48] Cementoma of the fibula: imaging findings with histopathologic correlation and review of the literature
    J. M. Mellado
    E. Mayayo
    F. Fernández
    L. Pérez del Palomar
    A. Camins
    A. Saurí
    Skeletal Radiology, 2005, 34 : 161 - 166
  • [49] CROSS-SECTIONAL IMAGING OF THE KIDNEY - CORRELATION TO HISTOPATHOLOGIC FINDINGS
    HONDA, H
    KUROIWA, T
    FUKUYA, T
    KANEKO, K
    YOSHIMITSU, K
    AIBE, H
    RADIOLOGY, 1995, 197 : 495 - 495
  • [50] Fluid-attenuated inversion-recovery imaging of cerebral infarction associated with tuberculous meningitis
    Nogami, K
    Nomura, S
    Kashiwagi, S
    Kato, S
    Yamashita, K
    Ito, H
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2000, 24 (05) : 333 - 337