Insulinoma: Correlation of short-TI inversion-recovery (STIR) imaging and histopathologic findings

被引:15
|
作者
Mori, M [1 ]
Fukuda, T [1 ]
Nagayoshi, K [1 ]
Kohzaki, S [1 ]
Matsunaga, N [1 ]
Hayashi, K [1 ]
Motojima, K [1 ]
Kanematsu, T [1 ]
机构
[1] NAGASAKI UNIV,SCH MED,DEPT SURG 2,NAGASAKI 852,JAPAN
来源
ABDOMINAL IMAGING | 1996年 / 21卷 / 04期
关键词
pancreas; insulinoma; MRI; STIR image;
D O I
10.1007/s002619900077
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
We studied the value of short-TI inversion-recovery (STIR) imaging for the localization of pancreatic insulinoma. Four patients (three women and one man aged 35-65 years) with surgically proven insulinoma were included in this study, All patients were examined by MR imaging with spin echo (SE) and STIR sequences, The STIR images were compared with the histopathologic findings in each case, In two patients, the tumors were markedly hyperintense on STIR images, and a 5-mm insulinoma was depicted only by this imaging method in one of the two. In the other two patients, 10-mm insulinomas were only slightly hyperintense on STIR images, The latter tumors had a higher content of collagen fibers than the former, indicating that the amount of collagen influences the signal intensity of insulinoma, Despite some limitations, STIR imaging is a useful noninvasive method for the localization of pancreatic insulinoma.
引用
收藏
页码:337 / 341
页数:5
相关论文
共 50 条
  • [1] SHORT-TI INVERSION-RECOVERY PULSE SEQUENCE - ANALYSIS AND INITIAL EXPERIENCE IN CANCER IMAGING
    DWYER, AJ
    FRANK, JA
    SANK, VJ
    REINIG, JW
    HICKEY, AM
    DOPPMAN, JL
    RADIOLOGY, 1988, 168 (03) : 827 - 836
  • [2] Enhancing fluid signal in driven-equilibrium short-TI inversion-recovery imaging with short TR times: A feasibility study
    von Deuster, Constantin
    Nanz, Daniel
    MAGNETIC RESONANCE IN MEDICINE, 2024, 92 (06) : 2571 - 2579
  • [3] FAST SHORT-TAU INVERSION-RECOVERY MR IMAGING
    FLECKENSTEIN, JL
    ARCHER, BT
    BARKER, BA
    VAUGHAN, JT
    PARKEY, RW
    PESHOCK, RM
    RADIOLOGY, 1991, 179 (02) : 499 - 504
  • [4] Orbital pseudotumors: Value of short inversion time inversion-recovery MR imaging
    Asao, C
    Korogi, Y
    Hotta, A
    Shimomura, O
    Kitajima, M
    Negi, A
    Takahashi, M
    RADIOLOGY, 1997, 202 (01) : 55 - 59
  • [5] SHORT TI INVERSION-RECOVERY IMAGING OF THE LIVER - PULSE-SEQUENCE OPTIMIZATION AND COMPARISON WITH SPIN-ECHO IMAGING
    DOUSSET, M
    WEISSLEDER, R
    HENDRICK, RE
    STARK, DD
    FRETZ, CJ
    ELIZONDO, G
    HAHN, PF
    SAINI, S
    FERRUCCI, JT
    RADIOLOGY, 1989, 171 (02) : 327 - 333
  • [6] MAGNETIC-RESONANCE-IMAGING FEATURES OF FRACTURES USING THE SHORT TAU INVERSION RECOVERY (STIR) SEQUENCE - CORRELATION WITH RADIOGRAPHIC FINDINGS
    MEYERS, SP
    WIENER, SN
    SKELETAL RADIOLOGY, 1991, 20 (07) : 499 - 507
  • [7] EFFECTIVENESS OF THE SHORT TI INVERSION RECOVERY (STIR) SEQUENCE IN MR IMAGING OF INTRAMEDULLARY SPINAL LESIONS
    MASCALCHI, M
    DALPOZZO, G
    BARTOLOZZI, C
    MAGNETIC RESONANCE IMAGING, 1993, 11 (01) : 17 - 25
  • [8] Diagnostic accuracy of N-stage in lung cancer using short inversion-time inversion-recovery (STIR) turbo spin-echo imaging
    Ohno, Y
    Hatabu, H
    Takenaka, D
    Higashino, T
    Watanabe, H
    Sugimura, K
    RADIOLOGY, 2002, 225 : 149 - 150
  • [9] Fluid-attenuated inversion-recovery SSFP imaging
    Bangerter, Neal K.
    Hargreaves, Brian A.
    Gold, Garry E.
    Stucker, Daniel T.
    Nishimura, Dwight G.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (06) : 1426 - 1431
  • [10] Fluid-attenuated inversion-recovery imaging of hemichorea
    Gallego, JC
    NEURORADIOLOGY, 2003, 45 (10) : 725 - 726