Studies on sensitivity, resolution, and Doppler broadening in gamma-ray imaging with pixellated semiconductor detectors

被引:5
|
作者
Lee, JH [1 ]
Lee, CS [1 ]
机构
[1] Chung Ang Univ, Dept Phys, Seoul 156756, South Korea
关键词
D O I
10.1016/j.nuclphysa.2004.09.100
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
We studied the Doppler broadening effect which is one of the major issues pertaining to overall imaging quality in Compton cameras. For the study of Doppler broadening due to the pre-collision electron momentum, we used a collimated beam of 662-keV gamma rays and selected events corresponding to the 90degrees Compton scattering using a Compton spectrometer, consisting of a 25-fold segmented germanium detector and a coaxial germanium detector shielded with a bismuth germanate (BGO) scintillator. Comparison of the energy spread due to Doppler broadening between a silicon and a germanium detector was made with the Monte Carlo simulation. To see the effect of Doppler broadening on the image resolution, we performed the Monte Carlo simulation in a simple backprojection method.
引用
收藏
页码:639C / 642C
页数:4
相关论文
共 50 条
  • [31] Electrode configuration and energy resolution in gamma-ray detectors
    Luke, P.N.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1996, 380 (1-2): : 232 - 237
  • [32] GE(LI) SEMICONDUCTOR DETECTORS AS HIGH-RESOLUTION GAMMA-RAY SPECTROMETERS IN NUCLEAR MEDICINE
    NAGAI, T
    NISHIU, S
    JOURNAL OF NUCLEAR MEDICINE, 1968, 9 (02) : 79 - +
  • [33] Spectral and Spatial Resolution of Semiconductor Detectors in Medical X- and Gamma Ray Imaging
    Heismann, B. J.
    Henseler, D.
    Niederloehner, D.
    Hackenschmied, P.
    Strassburg, M.
    Janssen, S.
    Wirth, S.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4885 - 4890
  • [34] A monolithic array of silicon drift detectors for high-resolution gamma-ray imaging
    Fiorini, C.
    Longoni, A.
    Perotti, F.
    Labanti, C.
    Rossi, E.
    Lechner, P.
    Soltau, H.
    Strüder, Lothar
    IEEE Transactions on Nuclear Science, 2002, 49 II (03) : 995 - 1000
  • [35] HIGH-RESOLUTION IMAGING GAMMA-RAY SPECTROSCOPY WITH EXTERNALLY SEGMENTED GERMANIUM DETECTORS
    CALLAS, JL
    MAHONEY, WA
    VARNELL, LS
    WHEATON, WA
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (01): : 143 - 153
  • [36] A monolithic array of silicon drift detectors for high-resolution gamma-ray imaging
    Fiorini, C
    Longoni, A
    Perotti, F
    Labanti, C
    Rossi, E
    Lechner, P
    Soltau, H
    Strüder, L
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 25 - 28
  • [37] A monolithic array of silicon drift detectors for high-resolution gamma-ray imaging
    Fiorini, C
    Longoni, A
    Perotti, F
    Labanti, C
    Rossi, E
    Lechner, P
    Soltau, H
    Strüder, L
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (03) : 995 - 1000
  • [38] ELECTRON DETECTION IN HIGH GAMMA-RAY BACKGROUND WITH SEMICONDUCTOR DETECTORS
    MAKOVSKI.LL
    STROKAN, NB
    SOVIET ATOMIC ENERGY, 1968, 25 (02): : 882 - +
  • [39] CHARGE-TRANSPORT IN ARRAYS OF SEMICONDUCTOR GAMMA-RAY DETECTORS
    BARRETT, HH
    ESKIN, JD
    BARBER, HB
    PHYSICAL REVIEW LETTERS, 1995, 75 (01) : 156 - 159
  • [40] DETERMINATION OF EFFICIENCIES OF SEMICONDUCTOR GAMMA-RAY DETECTORS FOR INHOMOGENEOUS SAMPLES
    KORUN, M
    MARTINCIC, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 335 (1-2): : 148 - 155