Correlation of Intraoperative Optical Coherence Tomography of Crystalline Lens Diameter, Thickness, and Volume with Biometry and Age

被引:16
|
作者
Waring, George Oral [1 ]
Chang, Daniel H. [2 ]
Rocha, Karolinne Maia [3 ]
Gouvea, Larissa [4 ]
Penatti, Raphael [1 ]
机构
[1] Waring Vis Inst, Mt Pleasant, SC USA
[2] Empire Eye & Laser Ctr, Bakersfield, CA USA
[3] Med Univ South Carolina, Storm Eye Inst, Charleston, SC 29425 USA
[4] Univ Toronto, Dept Ophthalmol & Vis Sci, Toronto, ON, Canada
关键词
REFRACTIVE-INDEX DISTRIBUTION; POWER CALCULATION; IN-VIVO; PRECISION BIOMETRY; ANTERIOR SEGMENT; AXIAL LENGTH; ACCOMMODATION; SHAPE; EYE; PARAMETERS;
D O I
10.1016/j.ajo.2020.12.021
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
center dot PURPOSE: To characterize crystalline lens dimensions derived from in vivo spectral-domain optical coherence tomography (SD-OCT) and identify associations among these parameters, ocular biometry, and age. center dot METHODS: In this retrospective study, lens thickness (LT), lens diameter (LD), and lens volume (LV) were measured intraoperatively using SD-OCT in 293 eyes undergoing lens surgery. Correlations among LT, LD, LV, age, axial length (AL), and anterior chamber depth (ACD) were analyzed. Multiple regression analysis was performed to determine whether a combination of biometric data could predict LD and LV. center dot RESULTS: Wide variations were observed in LT (3.65.7 mm), LD (7.5-11.9 mm), and LV (119.9312.4 mm3) of aging eyes. Correlations among the 3 lens dimensions were statistically significant (LV-LT: r = 0.785; P < .001; LV-LD: r = 0.696; P < .001; and LT-LD: r = 0.121; P = .039). With age, the correlation coefficients of LT, LD, and LV were 0.526, 0.326, and 0.573, respectively (P < .001). Although there was significant correlation of AL with LT (r = L0.137; P = .002) and LD (r = 0.268; P < .001), it was not significant with LV (r = 0.084; P = .15). Subgroup analysis revealed that 19.8% of long eyes had LD > 1 standard deviation (SD) above and that 5.2% had LD < 1 SD below the mean LD. center dot CONCLUSIONS: Dimensions of the aging lens vary considerably and are most accurately characterized by direct measurement of LT, LD, and LV, rather than making assumptions based on AL. These findings challenge historically proposed relationships between LD and AL and represent a normative dataset of contemporary geometric features of the aging lens, possibly aiding in surgical decision making and future developments in lenssurgery. (Am J Ophthalmol 2021;225:147-156. (c) 2020 Elsevier Inc. All rights reserved.) <comment>Superscript/Subscript Available</comment
引用
收藏
页码:147 / 156
页数:10
相关论文
共 50 条
  • [21] Association between axial length and in vivo human crystalline lens biometry during accommodation: a swept-source optical coherence tomography study
    Shoji, Takuhei
    Kato, Naoko
    Ishikawa, Sho
    Ibuki, Hisashi
    Yamada, Norihiro
    Kimura, Itaru
    Shinoda, Kei
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2020, 64 (01) : 93 - 101
  • [22] Association between axial length and in vivo human crystalline lens biometry during accommodation: a swept-source optical coherence tomography study
    Takuhei Shoji
    Naoko Kato
    Sho Ishikawa
    Hisashi Ibuki
    Norihiro Yamada
    Itaru Kimura
    Kei Shinoda
    Japanese Journal of Ophthalmology, 2020, 64 : 93 - 101
  • [23] Refractive index measurement of the mouse crystalline lens using optical coherence tomography
    Chakraborty, Ranjay
    Lacy, Kip D.
    Tan, Christopher C.
    Park, Han Na
    Pardue, Machelle T.
    EXPERIMENTAL EYE RESEARCH, 2014, 125 : 62 - 70
  • [24] Imaging of crystalline lens using a new anterior segment optical coherence tomography
    Mori, Haruhiro
    Ueno, Yuta
    Terauchi, Akari
    Hiraoka, Takahiro
    Oshika, Tetsuro
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [25] Refractive index measurement of the isolated crystalline lens using optical coherence tomography
    Uhlhorn, Stephen R.
    Borja, David
    Manns, Fabrice
    Parel, Jean-Marie
    VISION RESEARCH, 2008, 48 (27) : 2732 - 2738
  • [26] Swept source optical coherence tomography and tunable lens technology for comprehensive imaging and biometry of the whole eye
    Grulkowski, Ireneusz
    Manzanera, Silvestre
    Cwiklinski, Lukasz
    Sobczuk, Franciszek
    Karnowski, Karol
    Artal, Pablo
    OPTICA, 2018, 5 (01): : 52 - 59
  • [27] Impact and Correction of an Anterior Phakic Intraocular Lens on Swept-Source Optical Coherence Tomography Biometry
    Ribeiro, Bruno Barbosa
    Monteiro, Silvia
    Marques, Joao Heitor
    Abreu, Ana Carolina
    Pinto, Maria do Ceu
    JOURNAL OF REFRACTIVE SURGERY, 2024, 40 (08) : e562 - e568
  • [28] Age- and Hypertension-Dependent Changes in Retinal Vessel Diameter and Wall Thickness: An Optical Coherence Tomography Study
    Muraoka, Yuki
    Tsujikawa, Akitaka
    Kumagai, Kyoko
    Akiba, Masahiro
    Ogino, Ken
    Murakami, Tomoaki
    Akagi-Kurashige, Yumiko
    Miyamoto, Kazuaki
    Yoshimura, Nagahisa
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2013, 156 (04) : 706 - 714
  • [29] Correlation between optical coherence tomography and photographic measurements of macular hole diameter
    Gottlieb, JL
    Feldmann, MJ
    Gangnon, RE
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U805 - U805
  • [30] Posterior Vitreous Anatomy: Intraoperative Correlation With Spectral Domain Optical Coherence Tomography
    Margolis, R.
    Nam, W.
    Chang, S.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)